Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 7294 Rev C Print Date: 2014-05-19 Page 1 of 3 PB1002PFCDC Northwest Power, Inc. Data Sheet Power Bank PB1002PFCDC Power Supply Dual Input: AC and DC 1 or 2 Outputs Low-Profile 1.68" All specifications are at nominal input, full load, 25 °C, all models, unless otherwise noted. DC Input Nominal Input Voltage Options 24V 28V 48V Input Voltage Range 18-36V 10-36V 36-75V Output Power Based on specific module used AC Input Input Voltage (nominal) 115/230Vac Input Voltage Range 90-264Vac Input Frequency 47-63 Hz Inrush Current (cold start.) <20 A at 115Vac, <40A at 230Vac Input Fuse (internal) 20A Power Factor (minimum) 0.95 Input Harmonics EN 61000-3-2 Compliant Line dropout SEMI F47 Compliant when operated at 180-264Vac Output Power 850W max – Outputs A and B combined. See derating c urve. Output * A B Maximum Output Current (Connector Limit) 49A 49A Output Voltage (Factory configurable) 1.8 to 52 V 1 .8 to 52 V Module Size Options (AC side) Maxi or Mini Mini Module Size Options (DC side) Maxi or Mini Maxi or Mini Output Voltage Set point (50% load) ±1.2% ±1.2% Load Regulation, No load to full load (max.) ±0.2% ±0.2% Line Regulation, Low Line to High Line (max.) ±0.2% ±0.2% Maximum Output Power DC Input 48Vin; Output 12V 500W 500W Remote Sense Yes Yes Output Trim ±10% ±10% Output Ripple and Noise Vicor module specification Vicor module specification (*) Outputs A and B can be connected in parallel (with current sharing) or in series. Environmental Operating Temperature Range -20 °C to 70 °C Storage Temperature Range -40 °C to 70 °C Relative Humidity 5% -95% non-condensing Mechanical Dimensions 10.5" x 7" x 1.68" Cooling Internal Fans Outline Drawing Available on www.npi-inc.com Weight (Typical, depends on configuration) 6.6 lb. (3 kg)
Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 7294 Rev C Print Date: 2014-05-19 Page 2 of 3 PB1002PFCDC AC Input Connector Molex Sabre 43160-3103 Pin Signal Description Details
1 L1 AC Line Connection
2 Chassis Chassis Connection
3 L2/N AC Line or Neutral Connection
DC Input Connector Molex MFS 42820-2212 Pin Signal Description Details 1 +IN Positive Input Terminal 2 -IN Negative Input Terminal Outputs A and B Molex MFS 42820-4212 Pin Signal Description Details 1 + Output B Positive Terminal, 49A max 2 + Output A Positive Terminal, 49A max 3 - Output B Negative Terminal, 49A max 4 - Output A Negative Terminal, 49A max Trim/Remote Sense Connections for Channels A and B (AMP 102617-1) Pin Signal Description Details 1 +Sense A Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) 2 Trim A Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down. 3 - Sense A Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) 4 +Sense B Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) 5 Trim B Connect this pin with a resistor to Pin 4 for trim up, or to Pin 6 for trim down. 6 - Sense B Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) I/O Connections Molex 70555-0040 All control signals are isolated from AC and DC; Input - 3,000 Vrms; Output - 250 Vrms; Chassis - 250 Vrms Pin Signal Description Details
1 Inhibit DC-A Apply 24V** to inhibit Output B runn ing from DC input
2 Inhibit DC-B Apply 24V** to inhibit Output A runn ing from DC input
3 Inhibit AC-A Apply 24V** to inhibit Output A runn ing from AC input
4 Inhibit AC-B Apply 24V** to inhibit Output B runn ing from AC input
5 Not Connected
6 Control Return Reference for all signals on I/O c onnector. (**) Contact factory for other control voltage options. Safety Agency Approvals cTUVus, CE LVD Safety Standard Compliance EN 60950 Isolation, AC Primary-to-Secondary 3000Vrms Isolation, AC Primary-Earth 1500Vrms Isolation, Secondary-Earth 250Vrms
Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 7294 Rev C Print Date: 2014-05-19 Page 3 of 3 PB1002PFCDC Output Power Derating Maximum Output Power Operation from AC Input Source 400 600 800 1000 0 100 200 300 Input Voltage (AC) Output Power Northwest Power, Inc. Information furnished by NORTHWEST POWER is believed to be accurate and reliable. However, no responsibility is assumed by NORTHWEST POWER or Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of NORTHWEST POWER or Vicor. NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to NORTHWEST POWER 's Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Northwest Power, Inc. ♦ 4211 SE International Way, Suite F ♦ Milwaukie, OR, USA Tel: 503-652-6161 ♦ Fax: 503-652-6868 ♦ www.npi-inc.com