PAT6261.XXXNL PULSE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

P931.A (03/23) High Frequency Wire Wound Transformers EFD15+ Flyback Transformer Platform – PAT6261.XXXNL Series PulseElectronics.com Height: 10.5mm Max Footprint: 16.5mm x 22.23mm Topology: Flyback transformer Functional Insulation Isolation voltage: 1500Vrms (hi-pot) Operating Frequency: 250kHz Pulse PN Electrical Specifications @25°C – Operating Temperature -40°C to 125°C1 Schematic PAT6261.001NL Pri. Inductance (1, 2 - 3, 4) 24 µH ± 10% @ @ Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 1 µH max DCR (1, 2 - 3, 4) 80 mΩ max (5 -6) 420 mΩ max (12, 11, 10 - 7, 8, 9) 5.3 mΩ max Hi-Pot Pri - Sec 1500 Vrms PAT6261.002NL Pri. Inductance (1, 2 - 3, 4) 24 µH ± 10% 11.5V@50mA 5.0V@8A Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 1 µH max DCR (1, 2 - 3, 4) 70 mΩ max (5 -6) 370 mΩ max (12, 11, 10 - 7, 8, 9) 6.3 mΩ max Hi-Pot Pri - Sec 1500 Vrms PAT6261.003NL Pri. Inductance (1, 2 - 3, 4) 24 µH ± 10% 3.3A10.6V@ @ Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 1 µH max DCR (1, 2 - 3, 4) 70 mΩ max (5 -6) 370 mΩ max (12, 11, 10 - 7, 8, 9) 28 mΩ max Hi-Pot Pri - Sec 1500 Vrms PAT6261.004NL Pri. Inductance (1, 2 - 3, 4) 3 µH ± 10% @ @ Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 0.2 µH max DCR (1, 2 - 3, 4) 10 mΩ max (5 -6) 420 mΩ max (12, 11, 10 - 7, 8, 9) 3.50 mΩ max Hi-Pot Pri - Sec 1500 Vrms

P931.A (03/23) High Frequency Wire Wound Transformers EFD15+ Flyback Transformer Platform – PAT6261.XXXNL Series PulseElectronics.com 1. Storage Temperature: -40°C to 125°C 2. The temperature of the component (ambient plus temperature rise) must be within the stated operating temperature range. 3. Pri/Lk. Inductance value is measured at 100Khz/0.1Vrms. 4. Optional Tape & Reel packaging can be ordered by adding a “T” suffix to the part standard tape and reel specification EIA481. 5. For flyback topology applications, it is necessary to ensure that the transformer will not saturate in the application. The peak flux density (Bpk) should remain below 2700Gauss. To calculate the peak flux density use the following formula: Bpk (Gauss) = K1_Factor * Ipk(A) 6. In high volt- µsec applications, it is important to calculate the core loss of the transformer. Approximate transformer core loss can be calculated as: CoreLoss (W) = 4.6E-14 * (Freq_kHz)1.63 * (∆B_Gauss)2.63 where ∆B can be calculated as: For Flyback Topology: ∆B = K1_Factor * ∆(A) 7. For parties interested in K1 Factor values please contact Pulse Electronics. Notes: Pulse PN Electrical Specifications @25°C – Operating Temperature -40°C to 125°C1 Schematic PAT6261.005NL Pri. Inductance (1, 2 - 3, 4) 3 µH ± 10% @ @ Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 0.2 µH max DCR (1, 2 - 3, 4) 10 mΩ max (5 -6) 450 mΩ max (12, 11, 10 - 7, 8, 9) 4.20 mΩ max Hi-Pot Pri - Sec 1500 Vrms PAT6261.006NL Pri. Inductance (1, 2 - 3, 4) 3 µH ± 10% @ @ Lk. Inductance (1, 2 - 3, 4) with (12, 11, 10 - 7, 8, 9) shorted 0.2 µH max DCR (1, 2 - 3, 4) 12 mΩ max (5 -6) 375 mΩ max (12, 11, 10 - 7, 8, 9) 8 mΩ max Hi-Pot Pri - Sec 1500 Vrms

High Frequency Wire Wound Transformers EFD15+ Flyback Transformer Platform – PAT6261.XXXNL Series P931.A (03/23) For More Information: Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product names mentioned herein may be Americas - prodinfo_power_americas@ yageo.com | Europe - prodinfo_power_emea@yageo.com | Asia - prodinfo_power_asia@yageo.com PAT6261.XXXNL Mechanical Final Outline