P84C NORGREN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 9

Technical content

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2020-9331a) © 2015 Norgren Ltd. en 8.200.611.01 Technical features P84C 3/2 Control Valve Excelon® Plus Modular System > Port size: 3/8” ... 3/4” (ISO G/PTF) > Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products > High forward flow capacity > Fast Exhausting > 3 port/2 position valve, normally closed > Solenoid and air pilot options > For use as components in safety-related systems according to DIN EN ISO13849 up to a Performance Level (PL)c Cat. 1 Safety function: Safe Venting. Medium: Compressed air only Maximum supply pressure: 10 bar (145 psi) Minimum operating pressure: 3 bar (43 psi) Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Flow: 58 dm3/s at port size 1/2” Full flow P1 to P2 at 6,3 bar (91 psi) inlet, with 0,5 bar (7 psi) pressure drop P2 to P3 = 63 dm3/s. Ambient/Media temperature: Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Aluminium End Caps: Aluminum Body covers: ABS Elastomers: NBR Valve: Brass Air Pilot: Aluminium Technical data P84C Symbol Port Size Function Voltage Exhaust Port Weight (kg) Model 1012 1 3 G3/8 Solenoid/spring 24 V d.c. G1/2 1,0 P84C-3GT-PFN G1/2 Solenoid/spring 24 V d.c. G1/2 1,0 P84C-4GT-PFN G3/4 Solenoid/spring 24 V d.c. G1/2 1,0 P84C-6GT-PFN 1012 1 3 G3/8 Air/spring N/A G1/2 1,0 P84C-3GA-NNN G1/2 Air/spring N/A G1/2 1,0 P84C-4GA-NNN G3/4 Air/spring N/A G1/2 1,0 P84C-6GA-NNN Voltage tolerance: -10%/+15% Rating: 100% continuous duty Inlet orifice: 0,8mm Electrical connection: 15mm DIN EN 175301-803 (DIN 43650) Form C Manual override: Shrouded push button, spring return Protection class: IP65 Materials: PP5 (body), NBR (seals) Electrical details for solenoid operators

Pressure drop /uni0394p (bar) Pressure drop /uni0394p (bar) Air flow (dm 3 /s) Air flow (dm 3 /s) 100 100 P or t siz e: 3/8” P or t siz e: 1/2” 1,0 0,8 0,6 0,4 0,2 1,0 0,8 0,6 0,4 0,2 3.0 4.0 8.06.3 3.0 4.0 8.06.3 Inlet pressure (bar) Inlet pressure (bar) Perdita di carico Δp (bar) Portata d’aria (dm3/s) Pressione di ingresso (bar) Perdita di carico Δp (bar) Portata d’aria (dm3/s) Pressione di ingresso (bar) Our policy is one of continued research and development. We therefore reserve the right to amend, Flow characteristics Option selector Function Substitute 3/2 Control Valve C Port Size Substitute 3/8” 3 1/2” 4 3/4” 6 Thread Form Substitute PTF A ISO G G Port 1 to 2 Port size: 1/2” Port 1 to 2 Port size: 3/8” Voltage Substitute 24 V d.c. F 110 V a.c. A 220 V a.c. B Non N Solendoid Operator Substitute Non-Locking push button P Non N Operator *2) Substitute Air pilot*1) A Solenoid Operated T *1) To order air pilot models, select P84C-**A-NNN *2) ATEX statement can be found online https:/ /cdn.norgren.com/pdf/IM_Excelon_Plus_EN_final.pdf

Our policy is one of continued research and development. We therefore reserve the right to amend, Light Emitting Seals ,15mm form C Description Model Light Emitting Seals Circuit A (12 - 24 V d.c.) V10037-E13 Light Emitting Seals Circuit B (110 - 120 V a.c.) V10037-E18 Light Emitting Seals Circuit B (220 - 240 V a.c.) V10037-E19 Plug with with moulded cable and indicator Voltage Cable length (m) Model 12 - 24 V a.c. / d.c 1 V10014-D01 12 - 24 V a.c. / d.c 3 V10014-D03 110 V a.c. / d.c. 1 V10015-D01 110 V a.c. / d.c. 3 V10015-D03 220 V a.c. / d.c 1 V10016-D01 220 V a.c. / d.c 3 V10016-D03 Plug with moulded cable

Description

(m) Model 3 pin plug with moulded cable 1 V10013-D01 3 pin plug with moulded cable 3 V10013-D03 Plug with cable gland and indicator Description Model Plug with cable gland and indicator 12-24 V a.c. / d.c., c/w LED / VDR V10012-D13 Plug with cable gland and indicator 110 V a.c. / d.c., c/w LED / VDR V10012-D18 Plug with cable gland and indicator 220 V a.c. / d.c., c/w LED / VDR V10012-D19 M12 Adaptor Rear - MSUP Valve Plug Form C 8MM V13981-E01 M12 Adaptor Top - MSUP Valve Plug Form C 8MM V13980-E01 Plug with cable gland V10027-D00 Accessories Connection cable with plug,LED and M12 Female Description Cable length (m) Model PUR-Cable; M12/valve type C DIN connector 0,6 NC-DINCA-123MS-A

1 NC-DINCA-123MS-1

2 NC-DINCA-123MS-2

5 NC-DINCA-123MS-5

Our policy is one of continued research and development. We therefore reserve the right to amend, Accessories Quikclamp® Page 7 840014-51KIT Quikclamp® with bracket assembled Page 7 840014-52KIT Pressure sensing block 1/4 PTF Page 7 840016-50KIT Pressure sensing block G1/4 Page 7 840016-51KIT Port Adaptors Page 8 1/4 PTF 840015-01KIT 3/8 PTF 840015-02KIT 1/2 PTF 840015-03KIT 3/4 PTF 840015-04KIT G1/4 840015-09KIT G3/8 840015-10KIT G1/2 840015-11KIT G3/4 840015-12KIT Hybrid Quikclamp® *1 Page 7 840014-61 Hybrid Quikclamp® with bracket assembled *1 Page 7 840014-62 Full flow porting block 3/4” PTF Page 8 840028-50KIT Full flow porting block G3/4 Page 8 840028-53KIT Full flow porting block 3/4” PTF Page 8 840028-50KIT Full flow porting block G3/4 Page 8 840028-53KIT *1) To connect new Excelon Plus to old Excelon 74/73 units. Having the same hole centres as 74 series mounting bracket. A Quikclamp adds 13.6 mm to the overall width of a combination unit Pressure switch interface block (18D pressure switch) G1/4 Page 8 0337717000000000 Electronic Pressure Sensor – stand alone version *3 Q84G Pressure switch 18D (0,5 ... 8bar) *1 Page 8 0881300 Digital pressure switch Page 9 0860810 *1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 *3) Q84G stand alone electronic pressure sensor module Silencer Heavy duty muffler, 1/2” NPT male thread, brass wire element MB004A Heavy duty muffler, R1/2 male thread, brass wire element MB004B Voltage rating and spare coils Voltage Power Replacement 24 V d.c. 1,2 W 840650-50KIT 110 V a.c. 1,5 VA 840650-51KIT 220 V a.c. 1,5 VA 840650-52KIT

Our policy is one of continued research and development. We therefore reserve the right to amend, Dimensions Dimensions in mm Projection/First angle 1 1/2” exhaust port (NPT or ISO G)

Our policy is one of continued research and development. We therefore reserve the right to amend, Dimensions Air Pilot Operator Dimensions in mm Projection/First angle

11.5 119 54.3 24,5 46 102 6,5 90° ø 6,5 514 Our policy is one of continued research and development. We therefore reserve the right to amend, Dimensions in mm Projection/First angle Accessories Quikclamp®Quikclamp® with wall bracket Pressure sensing block Hybrid-Quikclamp® with wall bracket Hybrid-Quikclamp®

18 A/C

38.5 38.5 80 51 5746 G 1/4 G 1/8 300 6 5 Our policy is one of continued research and development. We therefore reserve the right to amend, 18D Pressure switchPorting block for 18D pressure switch 18D Porting block and 18D assembled Pipe adaptor Dimensions in mm Projection/First angle Full flow porting block horizontal Full flow porting block vertical

~300 31 G1/8 36,5 ~30 C Ø D B A Our policy is one of continued research and development. We therefore reserve the right to amend, 51D Pressure switch - digital

1 Switch OUT 1, green LED

2 Switch OUT 2, red LED

3 Dustproof protector

4 Connector M12 x 1

5 Inlet port

6 Alternative inlet port G1/8 plugged

7 Thread for mounting screw

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/ data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. EN - Englisch Silencer A B C D Model R1/2 17 92 32 32 MB004B 1/2 NPT 17 92 32 32 MB004A