Features

  • AC and DC coils.
  • Available with auxiliary switch.
  • Variety of main contact terminals.
  • For control of motors, power supplies, heating elements and lighting. Contact Data @ 25°C Arrangements: Up to 4 Form X (4PST -NO-DM) Ratings: See contact rating table. Material: Silver-cadmium oxide. Expected Life: 200,000 operations at full load. AC coil: 2 million operations, mechanical. DC coil: 10 million operations, mechanical. Minimum Contact Data: 3A @ 120VAC. Main Contact Ratings Auxiliary Snap-Action Switch Arrangements: Up to 2 Form C (DPDT). Rating: 10 amps at 120-250VAC @ 25°C. Material: Silver. Initial Dielectric Strength Initial Breakdown Voltage:2,200V rms minimum between all elements and between all elements to ground. Coil Data @ 25°C Voltage: From 12 to 120VDC, and 24 to 277VAC, 50/60 Hz. Power: DC, 7 .5 W; AC, 92VA, In rush; 12 VA Sealed. Duty Cycle: Continuous. Insulation Class: Class A, standard, Class B available. Initial Insulation Resistance: 100 megohms, minimum. Coil Data *Applicable for vertical mounting, but not for upside-down mounting. Note: Coil suppression is recommended for all DC coil units, particulary 120 and 240VDC coils. Operate Data Must-Operate Voltage:See coil data tables. Environmental Data T emperature Range:–55°C to +65°C. Mechanical Data Mounting: Universal mounting bracket. See outline drawings. T ermination: Contacts: Binder screw, box lug, captive pressure plate, combination screw and dual .250” (6.35mm) quick connect, or combination box lug and dual .250” (6.35mm) quick connect. See Main Contact Terminal Options photo. Coil: Combination 8-32 screw and .250” (6.35mm) quick connect. Aux. Switch: .187” (4.75mm) quick connect. Weight: 3 Pole Models: 25 oz. (709g) approximately. 4 Pole Models: 28 oz. (794g) approximately. P30 1Ø2P 1 .5HP 3HP — 3Ø3P 3HP 7 .5HP 7 .5HP P40 1Ø2P 2HP 5HP — 3Ø3P 5HP 10HP 15HP Motor Rating in HorsepowerType @ 120V @ 240V @ 440-600V P30 30A 180A 150A 120A 40A 40A P40 40A 240A 200A 160A 50A 50A Motor Rating in Amps, 3Ø3P or 1Ø2P Resistive T ungsten T ype Full Load Locked Rotor Rating Rating @ 600V @ 240V @480V @ 600V @ 600V @277V P30/P40 series Definite Purpose Magnetic Contactor 30/40 Ampere Full Load 40/50 Ampere Resistive AC & DC Coils File E22575 File LR15734 12 20.8 9 15 577 24 84 18 30 286 48 334 36 57 144 120 2,110 90 144 57 24 24 20.4 120 110/120 94 240 208/240 177 277 277 236 AC Voltage Nominal Must Operate* Rating 50/60 Hz. 50/60 Hz. Nominal Resistance Must Maximum Nominal Coil VDC (Ohms ± 10% Operate* Operating Current (ma) @ @ 25° C) Volts Volts Nominal Voltage DC Coil AC Coil Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application.

P&B Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 5-05) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. P30P42A12P1-120 P30P42D12P1-24 P30P47A12P1-120 P30P47D12P1-24 P40P42A12P1-24 P40P42A12P1-120 P40P42A12P1-240 P40P42D12P1-24 Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.

Ordering Information

T ypical Part No. B P30 P 42 A 1 4 P 1 -240 1. T ype: P30 = Definite Purpose Contactor, 30 amp. P40 = Definite Purpose Contactor, 40 amp. 2. Auxiliary Switch: P = No Aux. Switch C = 1 Form C (SPDT) F = 2 Form C (DPDT) 3. Main Contact Arrangement: 42 = 3 Form X (3PST -NO-DM) 47 = 4 Form X (4PST -NO-DM) 43 = 2 Form X (DPST -NO-DM) 48 = 2 Form X (DPST -NO-DM) & 1 Form Y (SPST -NC-DB) & 2 Form Y (DPST -NC-DB) 45 = 1 Form X (SPST -NO-DB) 49 = 4 Form Y (4PST -NC-DB) & 2 Form Y (DPST -NC-DB) Other contact arrangements are available. 4. Coil Control Input: A = Alternating Current, 50/60 Hz. D = Direct Current 5. Mounting and Installed Accessories: 1 = Standard Mounting 6. Main Contact T erminals: 2 = Screw Terminals 5 = Captive Pressure Plate 3 = Screw Terminals & Dual .250” (6.35mm) Quick Connect 6 = Box Lug & Dual .250” (6.35mm) Quick Connect 4 = Box Lug 7 . Auxiliary Contact T erminals: P = No Auxiliary Switch C = .187” (4.75mm) Quick Connect 8. Coil T erminals: 1 = Combination 8-32* Screw Terminal and .250” (6.35mm) Quick Connect 9. Coil Voltage: 24, 120, 240 or 277VAC 12, 24 or 120VDC

P&B Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 5-05) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Contact Replacement Kits Contact replacement kits for 3 pole models include 3 contact pressure springs, 3 movable contact assemblies and 6 stationary contact assemblies. Kits for 4 pole models include 4 contact pressure springs, 4 movable contact assemblies and 8 stationary contact assemblies. Contact replacement kits are for use only on those models with form X contact arrangements. Main Contact Ordering and Replacement Information Kits for P30 contactors: 3 Form X models - Kit No. 9P30X1 4 Form X models - Kit No. 9P30X2 Kits for P40 contactors: 3 Form X models - Kit No. 9P40X1 4 Form X models - Kit No. 9P40X2 T o Replace Contacts: 1. Remove screws holding dust cover in place, and remove cover. 2. Compress and remove contact pressure springs. 3. Lift movable contacts and remove. 4. Remove screws holding stationary contact in place, and remove contacts. 5. Reverse the above procedure to install new stationary and movable contacts. Caution: Do not overtighten the screws, as it is possible to strip the threads. Outline Dimensions Dual .250” (6.35mm) Quick Connect 26A945 Binder Terminal Screw 15S365 accepts the following wire size: Solid, Single — 8 AWG Code 3 Binder Terminal Screw 15S365 accepts the following wire size: Solid, Single — 8 AWG Code 2 Screw with Captive Pressure Plate 15S362 Accepts the following wire sizes: Solid, Single —22-8 AWG Solid, Double —22-14 AWG Stranded, Single —22-8 AWG Stranded, Double —22-16 AWG Code 5 Box Lug (Keyed) 24C540 with 15S361 & 15S364 Screws Accepts the following wire sizes: Solid, Single —14-4 AWG Code 4 Dual .250” (6.35mm) Quick Connect 26A945 Box Lug 9P30X3 Accepts the following wire sizes: Solid, Single —14-4 AWG Code 6 Contact T erminal Options 3.420 MAX. (86.87) 3.550 MAX. (79.38 ± .25) .21 TYP. (5.3) 2.550 (64.77) .25 TYP. (8.4) 2.00 (50.8) 1.500 ± .020 (38.10 ± .51) 3.250 ± .010 (82.55 ± .25) .5 DIA. (12.7)3.800 MAX. (96.52) 3.350 MAX. (85.09) W/O SWITCH 3.600 MAX. (91.44) W/SWITCH 3.975 MAX. (100.97) 3.550 MAX. (90.17)

3 Pole Models

4 Pole Models

3.420 MAX. (86.87) 3.550 MAX. (90.17) 3.125 ± .010 (79.38 ± .25) .21 TYP. (5.3) 2.550 (64.77) .25 TYP. (6.4) 2.00 (50.8) 1.500 ± .020 (38.10 ± .51) 3.250 ± .010 (82.55 ± .25) .5 DIA. (12.7) 3.800 MAX. (96.52) 2.650 MAX. (67.31) W/O SWITCH 3.25 MAX. (82.55) W/SWITCH 3.975 MAX. (100.97) 3.550 MAX. (90.17) DC Coil DC Coil