P3800 MPSIND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Tel: 310-325-1043 Fax: 310-325-1044 www.mpsind.com sales@mpsind.com P3800 SERIES

  • Isolated flyback transformers with high output voltage
  • Ideal for use in medical applications
  • Input: 12-30Vdc, Output: 1KV - 2KV
  • Isolation: 4000 Vdc (primary and core to secondary)
  • Operating Temperature: -40°C to +85°C
  • RoHS Compliant Product
  • Custom Design Available ELECTRICAL PARAMETERS @25°C Part Number P3800- Power Output (W) Input Voltage (Vdc) Switching Frequency (KHz) Primary OCL (4-3) (µH ±10%) Primary DCR (4-3) (mΩ Max) Turns Ratio (Pri : Sec) (±3%) Secondary DCR (8-12) (Ω Max) 1 50 12 50 6 8 1 : 100 130 2 70 18 60 8 10 1 : 70 90 3 80 18 80 5 8 1 : 80 42 4 100 24 80 8 10 1 : 60 30 5 150 30 100 6 10 1 : 60 30 NOTES:
  • Primary OCL (4-3) measured at 10KHz, 0.1Vrms
  • Hi-pot: 4000Vdc, 0.5mA, 5s (Pri and Core to Sec), 500Vdc, 0.5mA, 5s (Pri to Core) Product performance is limited to specified parameters. Data is subject to change without prior notice. ISOLATED FLYBACK TRANSFORMERS DIMENSIONS (mm) SCHEMATIC Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ±0.015 .XXX : ±0.004 mm: X,X : ±0,38 X,XX : ±0,10