Supersedes data of September 2004 2008 Sep 01 FERROXCUBE P36/22 P cores and accessories
2008 Sep 01 1017
P cores and accessories P36/22 CORE SETS Effective core parameters SYMBOL PARAMETER VALUE UNIT Σ(I/A) core factor (C1) 0.264 mm −1 Ve effective volume 10700 mm 3 Ie effective length 53.2 mm Ae effective area 202 mm 2 Amin minimum area 172 mm 2 m mass of set ≈ 54 g CBW429 4.9 ±0.616.2 0 −0.6 −1.229.9 +1 0 36.2 26.2 ±0.6 ∅5.4 +0.2 14.6 +0.4 21.7 ±0.3 0.5 +0.2 Fig.1 P36/22 core set. Dimensions in mm. Core sets for general purpose transformers and power applications Clamping force for AL measurements, 350 ±50 N. GRADE AL (nH) µe TOTAL AIR GAP (µm) TYPE NUMBER 3C81 315 ±3% ≈ 66 ≈ 970 P36/22-3C81-E315 400 ±3% ≈ 84 ≈ 730 P36/22-3C81-E400 630 ±3% ≈ 132 ≈ 430 P36/22-3C81-A630 1000 ±3% ≈ 210 ≈ 250 P36/22-3C81-A1000 1600 ±5% ≈ 335 ≈ 150 P36/22-3C81-A1600 10800 ±25% ≈ 2260 ≈ 0 P36/22-3C81 3C91 10800 ±25% ≈ 2260 ≈ 0 P36/22-3C91 3F3 250 ±3% ≈ 52 ≈ 1340 P36/22-3F3-E250 315 ±3% ≈ 66 ≈ 970 P36/22-3F3-E315 400 ±3% ≈ 84 ≈ 730 P36/22-3F3-E400 630 ±3% ≈ 132 ≈ 430 P36/22-3F3-A630 1000 ±3% ≈ 210 ≈ 250 P36/22-3F3-A1000 1600 ±5% ≈ 335 ≈ 150 P36/22-3F3-A1600 7350 ±25% ≈ 1540 ≈ 0 P36/22-3F3
2008 Sep 01 1018
P cores and accessories P36/22 Core sets of high permeability grades Clamping force for AL measurements, 350 ± 50 N. Properties of core sets under power conditions Note 1. Measured at 60 °C. GRADE AL (nH) µe AIR GAP (µm) TYPE NUMBER 3E27 17500 ±25% ≈ 3670 ≈ 0 P36/22-3E27 GRADE B( m T )a t C O R EL O S S( W )a t H=2 5 0A / m ; f = 25 kHz; T = 100 °C f = 25 kHz; =2 0 0m T ; T = 100 °C f=1 0 0k H z ; =1 0 0m T ; T=1 0 0 °C f=1 0 0k H z ; = 200 mT; T = 100 °C f = 400 kHz; =5 0m T ; T = 100 °C Bˆ Bˆ Bˆ Bˆ
2008 Sep 01 1019
P cores and accessories P36/22 COIL FORMERS General data for coil former CP-P36/22 Winding data and area product for coil former CP-P36/22 PARAMETER SPECIFICATION Coil former material polybutyleneterephtalate (PBT), glass reinforced, flame retardant in accordance with “UL 94V-0”; UL file number E45329 (R) Maximum operating temperature 155 °C, “IEC 60085”, class F NUMBER OF SECTIONS WINDING AREA (mm2) MINIMUM WINDING WIDTH (mm) AVERAGE LENGTH OF TURN (mm) AREA PRODUCT Ae x Aw (mm4) TYPE NUMBER 1 72.4 12.5 74.3 14600 CP-P36/22-1S 22 × 33.9 2 × 5.8 74.3 2 x 6850 CP-P36/22-2S 33 × 21.0 3 × 3.6 74.3 3 x 4240 CP-P36/22-3S handbook, full pagewidth MGC141 17.9 0 0.23.4 16.5 0.2 29.6 0 0.2 0.8 0.8 0.7 0.7 14.4 0 0.2 Fig.2 Coil former CP-P36/22. Dimensions in mm.
2008 Sep 01 1020
P cores and accessories P36/22 MOUNTING PARTS General data and ordering information ITEM REMARKS FIGURE TYPE NUMBER Tag plate material: phenolformaldehyde (PF), glass reinforced 3 TGP-P36/22-C flame retardant: in accordance with “UL 94V-0”; UL file number E41429 maximum operating temperature: 180 °C, “IEC 60085”, class H pins: copper-tin alloy (CuSn), tin (Sn) plated resistance to soldering heat in accordance with “IEC 60068-2-20”, Part 2, Test Tb, method 1B: 350 °C, 3.5 s solderability in accordance with “IEC 60068-2-20”, Part 2, Test Ta, method 1: 235°C, 2 s Container copper-zinc alloy (CuZn), tin (Sn) plated 4 CON-P36/22 earth pins: presoldered Spring CrNi-steel 5 SPR-P36/22 spring force: ≈350 N when mounted handbook, full pagewidth 2.1 2.2 15.24 10.16 5.0820.32 15.24 mark 37.9 max. 5.0 ∅8.4 ∅0.8 2.54 CBW605 1.3 +0.15 Fig.3 Tag plate: TGP-P36/22-C. Dimensions in mm.
2008 Sep 01 1021
P cores and accessories P36/22 handbook, full pagewidth CBW430 mark 9 24.5 max. 38.2 max. 33.75 min. 8.2 0.6 Fig.4 P36/22 container. Dimensions in mm. handbook, halfpage MGC144 34.7 max 2.3 0.3 Fig.5 P36/22 spring. Dimensions in mm.
2008 Sep 01 1022
P cores and accessories P36/22 DATA SHEET STATUS DEFINITIONS DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains prelimin ary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.