CATV Line Amplifiers/Power Inserters ME SIDACtor Device http://www.littelfuse.com 2 - 62 © 2004 Littelfuse, Inc. +1 972-580-7777 SIDACtor ® Data Book and Design Guide CATV Line Amplifiers/Power Inserters ME SIDACtor Device This SIDACtor device is a 5000 A solid state protection device offered in a non-isolated TO-218 package. It protects equipment located in the severe surge environment of CATV (Community Antenna TV) applications. In CATV line amplifiers and power inserters, this device can replace the gas tubes traditionally used for station protection because SIDACtor devices have much tighter voltage tolerances. * For surge ratings, see table below. ** IT is a free air rating; heat sink IT rating is 25 A. General Notes:

  • All measurements are made at an ambient temperature of 25 °C. I PP applies to -40 °C through +85 °C temperature range.
  • I PP is a repetitive surge rating and is guaranteed for the life of the product.
  • Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
  • V DRM is measured at IDRM.
  • V S is measured at 100 V/µs.
  • Special voltage (V S and VDRM) and holding current (IH) requirements are available upon request.
  • Off-state capacitance (C O) is measured at 1 MHz with a 2 V bias and is a typical value. Electrical Parameters Part Number * VDRM Volts VS Volts VT Volts IDRM µAmps IS mAmps IT Amps ** IH mAmps CO pF P1500ME 140 180 4 5 800 2.2/25 50 750 P1900ME 140 220 4 5 800 2.2/25 50 750 P2300ME 180 260 4 5 800 2.2/25 50 750 Surge Ratings Series IPP 8x20 µs Amps ITSM 60 Hz Amps di/dt Amps/µs E 5000 400 630

CATV Line Amplifiers/Power Inserters ME SIDACtor Device © 2004 Littelfuse, Inc. 2 - 63 http://www.littelfuse.com SIDACtor® Data Book and Design Guide +1 972-580-7777 Data Sheets * RθJC rating assumes the use of a heat sink and on state mode for extended time at 25 A, with average power dissipation of 29.125 W. Thermal Considerations Package Symbol Parameter Value Unit TO-218 TJ Operating Junction Temperature Range -40 to +150 °C TS Storage Temperature Range -65 to +150 °C TC Maximum Case Temperature 100 °C RθJC * Thermal Resistance: Junction to Case 1.7 °C/W RθJA Thermal Resistance: Junction to Ambient 56 °C/W 1 2 3 (No Connection) IH IT IS IDRM VDRMVT +V-V VS IH IT IS IDRM VDRMVT +V-V VS V-I Characteristics 100 tr td Peak Value Half Value t – Time (µs) IPP – Peak Pulse Current – %IPP tr = rise time to peak value td = decay time to half value Waveform = tr x td tr x td Pulse Wave-form -40 -20 0 20 40 60 80 100 120 140 160 Junction Temperature (TJ) – ˚C Percent of VS Change – % 25 ˚C Normalized VS Change versus Junction Temperature 0.4 -40 -20 0 20 40 60 80 100 120 140 160 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Case Temperature (TC ) – ˚C Ratio of IH IH (TC = 25 ˚C) 25 ˚C Normalized DC Holding Current versus Case Temperature