OVP-12 POWER-ONE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
Features
Description
OVERVOLTAGE PROTECTION OPTIONS These optional overvoltage protection modules are offered for use with Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V. OVP SELECTION GUIDE MODEL CASE SIZE OVP MODULES REQUIRED SINGLE B,C,N,D (1) OVP-12 OUTPUT E,F (1) OVP-24 DUAL AA,B,BB,CC (1) OVP-12 protects both outputs OUTPUT E (1) OVP-24 protects both outputs TRIPLE AA,BAA,D (1) OVP-12 protects both 12V OUTPUT CBB, 131 through 15V outputs DBB,DCC PEAK N,BAA,CBB CURRENT 131, CP340-A (1) OVP-12 protects any output MODELS CP510-A not provided with built-in OVP NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48V through 250V models. OVP-12 OVP-24 Overvoltage Protection Options Ordering Information: To order a model with RoHS lead solder exemption compliance, no RoHS suffix character is required to be added to the part number. To order a model that is RoHS compliant for all six substances, add “G” as the last character of the part number.
SEP 26, 2006 revised to MAR 06, 2007 Page 2 of 9 www.power-one.com Linear Power Supplies Data Sheet (See Additional Features Column) A Overvoltage protection, set at 6.2 V ±0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. Case Dimensions Type (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 CP510-A 8.25 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 Case Dimensions Type (Millimeters) AA 165.10 x 101.60 x 53.34 B 123.70 x 101.60 x 53.34 BAA 260.35 x 101.60 x 74.93 BB 177.80 x 123.70 x 74.93 C 142.75 x 123.70 x 74.93 CBB 279.40 x 123.70 x 83.31 CC 238.25 x 123.70 x 83.31 CP131 279.40 x 123.70 x 83.31 CP510-A 209.55 x 123.70 x 83.31 D 228.60 x 123.70 x 83.31 DBB 361.95 x 123.70 x 85.85 DCC 381.00 x 123.95 x 115.57 E 355.60 x 123.70 x 89.66 F 425.50 x 123.95 x 127.00 N 177.80 x 123.70 x 83.31 Nominal Max Model Input Case Additional Vout* Amps 100 to 264 VAC Type Features & Notes 5Vout 5 1.5 HAA5-1.5/OVP-A B A 5 3 HB5-3/OVP-A B A, C 5 6 HC5-6/OVP-A C A, C 5 9 HN5-9/OVP-A N A, C 5 12 HD5-12/OVP-A D A, C 5 18 HE5-18/OVP-A E A, C 5 25 F5-25/OVP-A F A, C, D, H 5 35 G5-35/OVP-A F A, C, D, H 5 50 CP197-A F A, C, D 12 to 15Vout 12 0.9 HA15-0.9-A B 12 1.7 HB12-1.7-A B C 12 3.4 HC12-3.4-A C C 12 5.1 HN12-5.1-A N C 12 6.8 HD12-6.8-A D C 12 10.2 HE12-10.2-A E C 12 16 F15-15-A F C, D, H 15* 0.9 HA15-0.9-A B 15 1.5 HB15-1.5-A B C 15 3 HC15-3-A C C 15 4.5 HN15-4.5-A N C 15 6 HD15-6-A D C 15 9 HE15-9-A E C 15* 15 F15-15-A F C, D, H 24 to 28Vout 24 0.5 HA24-0.5-A B 24 1.2 HB24-1.2-A B C 24 2.4 HC24-2.4-A C C 24 3.6 HN24-3.6-A N C 24 4.8 HD24-4.8-A D C 24 7.2 HE24-7.2-A E C 24 12 F24-12-A F C, D, H 28* 0.5 HA24-0.5-A B 28 1 HB28-1-A B C 28 2 HC28-2-A C C 28 3 HN28-3-A N C 28 4 HD28-4-A D C 28 6 HE28-6-A E C 28* 10 F24-12-A F C, D, H 48Vout 48 0.5 HB48-0.5-A B 48 1 HC48-1-A C 48 3 HD48-3-A D C 48 4 HE48-4-A E C * May require jumpering or potentiometer adjustment. Unsigned output voltages are isolated and can be used as either + or - polarities.
Nominal Max Model Input Case Additional Vout* Amps 100 to 264 VAC Type Features & Notes 5V to 15Vout +5, –5 1.5, 1.5 HAA5-1.5/OVP-A AA A +5, –5 3, 3 HBB5-3/OVP-A BB A +5, –5 6, 6 HCC5-6/OVP-A CC A, C +5, +12 2, 4 CP323-A N A, E +5, +12 6, 2.5 CP510-A CP510-A A 5, 12 to 15 2, 0.5 HAA512-A AA A 5, 12 to 15 3, 1.25 HBB512-A BB A, C 5, 12 to 15 6, 2.5 HCC512-A CC A, C +12, –12 1, 1 HAA15-0.8-A AA C +12, –12 3.4, 3.4 HCC15-3-A CC C +12, –12* 5, 5 HDD15-5-A E C +12, –15* 5, 5 HDD15-5-A E C 15, –12* 5, 5 HDD15-5-A E C 15V to 24Vout +15, –15* 3, 3 HCC15-3-A CC C +15, –15 5, 5 HDD15-5-A E C Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 3 of 9 www.power-one.com (See Additional Features Column) A Overvoltage protection, set at 6.2 V ±0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. Case Dimensions Type (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 CP510-A 8.25 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 Case Dimensions Type (Millimeters) AA 165.10 x 101.60 x 53.34 B 123.70 x 101.60 x 53.34 BAA 260.35 x 101.60 x 74.93 BB 177.80 x 123.70 x 74.93 C 142.75 x 123.70 x 74.93 CBB 279.40 x 123.70 x 83.31 CC 238.25 x 123.70 x 83.31 CP131 279.40 x 123.70 x 83.31 CP510-A 209.55 x 123.70 x 83.31 D 228.60 x 123.70 x 83.31 DBB 361.95 x 123.70 x 85.85 DCC 381.00 x 123.95 x 115.57 E 355.60 x 123.70 x 89.66 F 425.50 x 123.95 x 127.00 N 177.80 x 123.70 x 83.31 Model numbers highlighted in yellow or shaded are not recommended for new designs. Unsigned output voltages are isolated and can be used as either + or - polarities. * May require jumpering or potentiometer adjustment.
SEP 26, 2006 revised to MAR 06, 2007 Page 4 of 9 www.power-one.com Linear Power Supplies Data Sheet (See Additional Features Column) A Overvoltage protection, set at 6.2 V ±0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. Case Dimensions Type (Inches) AA 6.50 x 4.00 x 2.10 B 4.87 x 4.00 x 2.10 BAA 10.25 x 4.00 x 2.95 BB 7.00 x 4.87 x 2.95 C 5.62 x 4.87 x 2.95 CBB 11.00 x 4.87 x 3.28 CC 9.38 x 4.87 x 3.28 CP131 11.00 x 4.87 x 3.28 CP510-A 8.25 x 4.87 x 3.28 D 9.00 x 4.87 x 3.28 DBB 14.25 x 4.87 x 3.38 DCC 15.00 x 4.88 x 4.55 E 14.00 x 4.87 x 3.53 F 16.75 x 4.88 x 5.00 N 7.00 x 4.87 x 3.28 Case Dimensions Type (Millimeters) AA 165.10 x 101.60 x 53.34 B 123.70 x 101.60 x 53.34 BAA 260.35 x 101.60 x 74.93 BB 177.80 x 123.70 x 74.93 C 142.75 x 123.70 x 74.93 CBB 279.40 x 123.70 x 83.31 CC 238.25 x 123.70 x 83.31 CP131 279.40 x 123.70 x 83.31 CP510-A 209.55 x 123.70 x 83.31 D 228.60 x 123.70 x 83.31 DBB 361.95 x 123.70 x 85.85 DCC 381.00 x 123.95 x 115.57 E 355.60 x 123.70 x 89.66 F 425.50 x 123.95 x 127.00 N 177.80 x 123.70 x 83.31 Model numbers highlighted in yellow or shaded are not recommended for new designs. Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Max Model Input Case Additional Vout* Amps 100 to 264 VAC Type Features & Notes Triple Output Models, 5V to 24Vout 5, +12, –5* 3, 1, 0.4 HBAA-40W-A BAA A, C +5, +12, –5 6, 5, 0.25 CP498-A CP131 A, C, F 5, +12, –5* 6, 1.7, 0.7 HCBB-75W-A CBB C 5, +12, –12 3, 1, 1 HBAA-40W-A BAA A, C 5, +12, –12 6, 1.7, 1.7 HCBB-75W-A CBB C +5, +12, –12 6, 5, 0.5 CP498-A CP131 A, C, F 5, +12, –12 8, 1.7, 1.7 CP131-A CP131 A, C 5, +12, –12 12, 1.7, 1.7 HDBB-105W-A DBB C 5, +12, –12 12, 3.4, 3.4 HDCC-150W-A DCC A, C 5, +12, –15* 3, 1, 0.8 HBAA-40W-A BAA A, C 5, +12, –15 6, 1.7, 1.5 HCBB-75W-A CBB C 5, +12, –15 8, 1.7, 1.5 CP131-A CP131 A, C 5, +12, –15 12, 3.4, 3 HDCC-150W-A DCC A, C 5, -12, 24 6, 1.2, 3.5 CP379-A CP131 A, C, F, G 5, +15, –5* 3, 0.8, 0.4 HBAA-40W-A BAA A, C 5, +15, –5* 6, 1.5, 0.7 HCBB-75W-A CBB C 5, +15, –12* 3, 0.8, 1 HBAA-40W-A BAA A, C 5, +15, –12 6, 1.5, 1.7 HCBB-75W-A CBB C 5, +15, –12 8, 1.5, 1.7 CP131-A CP131 A, C 5, +15, –12 12, 3, 3.4 HDCC-150W-A DCC A, C 5, +15, –15* 3, 0.8, 0.8 HBAA-40W-A BAA A, C 5, +15, –15 6, 1.5, 1.5 HCBB-75W-A CBB C 5, +15, –15 8, 1.5, 1.5 CP131-A CP131 A, C 5, +15, –15 12, 3, 3 HDCC-150W-A DCC A, C Quad Output Models, 5V to 24Vout 5, +12, –12, +24 6, 1, 1, 2.4 CP503-A CP131 A, H * May require jumpering or potentiometer adjustment.
Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 5 of 9 www.power-one.com Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Jumper selectable, shipped factory configured for 100 VAC Tap 87 100 110 (Note 1, 2) 120VAC operation. All models must be externally 120 VAC Tap 104 120 132 VACfused for proper operation. Fuse ratings are marked 220 VAC Tap 191 220 242 on each unit. Consult factory for each unit’s fuse 240 VAC Tap 209 240 264 requirements. Input Frequency AC input. 47 63 Hz Line Regulation Output voltage charge for a 10% line change: F case models. -0.01 +0.01 All other models. -0.05 +0.05 NOTES: 1) Derate output current 10% for 50Hz operation. 2) Input voltage tolerance for 230VAC operation is +15%, -10%. Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Output Adjustment Minimum output adjustment range (Note 1). -5 +5 % Efficiency 5 volt outputs. 45 12 volt and 15 volt outputs. 55 % 24 volt and higher outputs. 60 F case models. 3.0 mV PK-PK Ripple and Noise 5 volt, 12 volt, and 15 volt models. 5.0 mV PK-PK (Note 2) All three terminal regulator outputs. 0.2 % PK-PK 24 volt through 250 volt models. 3.0mV PK-PK plus 0.02% of output voltage, max Load Regulation Output change for a 50% load change: F case models. -0.02 +0.02 HAD12, HAD15. -1 +1 %Outputs with adjustable three terminal regulators. -0.5 +0.5 All other models. -0.05 +0.05 Transient Response Recovery time, to within 1% of initial set point due to a 50% load change. 50 μs NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of nominal voltage. Locate the “Vadj” potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3-terminal regulator outputs are not adjustable . 2) Full load, 20MHz bandwidth. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL60950 3rd Edition. CSA 60950 3rd Edition. Approved EN60950 3rd Edition. IEC60950 3rd Edition Dielectric Withstand Input to output. 3750 VRMS Voltage Input to ground. 3750 Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted. Interference EN55022 / CISPR 22 conducted. Compatible with system compliance to Level B. EN55022 / CISPR 22 radiated. Leakage Current Per EN60950 (264VAC) 23 50 μA Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on 5 volt output units where indicated. 5.8 6.6 V Other outputs may use optional overvoltage protectors OVP-12 and OVP-24. Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV Provided on models where indicated. Overcurrent/Short Circuit Automatic current limit/foldback. Rated as a percentage of output power. 115 120 140 %Protection Master/Slave Operation For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factor y for application notes. Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exemption No RoHS suffix character required. RoHS compliant for all six substances Add “G” as the last character of the part number.
SEP 26, 2006 revised to MAR 06, 2007 Page 6 of 9 www.power-one.com Linear Power Supplies Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Operating Temperature Derate output power linearly above 50°C by 3% per °C. At 100% load 0 50 °C At 40% load 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 50°C (after 15 minute warm-up). 0.1 0.3 %/°C 24 hours after warm-up. -0.3 +0.3 % Shock Operating. 20 G PK Vibration Random vibration from 10 Hz to 2 kHz, 3 axis. 6.15 G RMS Relative Humidity Non-Condensing. 5 95 %RH
Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 7 of 9 www.power-one.com
SEP 26, 2006 revised to MAR 06, 2007 Page 8 of 9 www.power-one.com Linear Power Supplies Data Sheet
Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 9 of 9 www.power-one.com NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.