(Model OVA 5000) www.lunainc.com

3157 State Street | Blacksburg, VA 24060

solutions@lunainc.com Support phone: 1.866.586.2682 With the OVA 5000, development cost, production cost and time to market for DWDM components can be reduced by up to 60%. KEY FEATURES AND PRODUCT HIGHLIGHTS

  • Single measurement, all-parameter analysis of devices up to 150 m in length
  • Full C and L band characterization in under 3 seconds
  • High resolution C and L band or O band capability
  • Complete polarization response
  • Real-time measurements
  • User-friendly interface The Luna OVA 5000 is the fastest, most accurate and economical tool for loss, dispersion and polarization measurements of modern optical networking equipment. It is the ideal device for single-connection, all-parameter characterization of fiber components from couplers to specialty fiber and everything in between (Fiber Bragg Gratings, arrayed waveguide gratings, free-space filters, tunable devices, amplifiers, etc.), all with a single sweep of a tunable laser. Luna’s patented characterization technique allows direct measurement of a passive device’s linear transfer function allowing the OVA instant access to:
  • Insertion Loss (IL)
  • Polarization Dependent Loss (PDL)
  • Polarization Mode Dispersion (PMD) and Second Order PMD
  • Chromatic Dispersion (CD)
  • Group Delay (GD)
  • Optical Time Domain Response
  • Jones Matrix Elements
  • Optical Phase Response

Optical Vector AnalyzerTM is a trademark of Luna Innovations Incorporated. ©Luna Innovations Incorporated, Roanoke, VA All rights reserved. OVA 5000 LT0VA5000 REV. 005 02/13/2014 PARAMETER FAST MODE* AVERAGING MODE* UNITS Wavelength Range: 1270-1340 or 1525-1610 nm Wavelength: Standard Resolution 1.6 1.6 pm Accuracy1 ±1.5 ±1.5 pm Repeatability ±0.1 ±0.1 pm Optical Phase Error: ±0.05 ±0.0075 radians Loss Characteristics: Dynamic range2 60 80 dB Ripple ±0.05 ±0.01 dB Resolution ±0.05 ±0.002 dB Insertion loss accuracy ±0.1 ±0.05 dB Return loss accuracy ±0.2 ±0.1 dB Chromatic Dispersion: Accuracy ±10 ±5 ps/nm Group Delay: Range3 6 6 ns Accuracy ±0.2 ±0.1 ps Loss range2 45 60 dB PMD: Range3 6 6 ns Accuracy – First Order ±0.03 (100pm steps) ±0.15 (30pm steps) ±0.08 ps Accuracy – Second Order ±10 ±2 ps2 Loss range2 40 50 dB PDL: Extinction ratio 40 50 dB Accuracy ±0.05 ±0.03 dB Measurement Timing: Laser sweep rate 70 70 nm/s All-parameter measurement rate4 30 30 ms/nm Fully specified measurement time5 12 55 s Real-time mode update rate6 1 NA Hz Maximum Device Length (including leads): Transmission 150 150 meters Reflection 75 75 meters Physical Weight (Processor not Included) 16.24 35.8 kg lbs Case Size (W X D X H) 473 X 420 X 206 18.62 X 16.54 X 8.08 mm inches 1 Accuracy maintained by an internal NIST-traceable HCN gas cell. 2 80, 60 and 50 dB dynamic ranges in ‘Averaging Mode’ for IL, GD and PMD are with the “High Dynamic Range Averaging” option installed and enabled. 3 Specifies the total device impulse-response duration that may be captured. 4 Rate calculated from combined laser sweep and analysis time per scan.

5 Measurement with full specification (see note 2) over Fast Mode: 40 nm range, and

Averaging Mode: 2.5 nm range. Excludes calibration time. 6 For 2.5 nm scan range. Fast Mode: no averaged calibration scans, 4 averaged measurement scans, 30 pm resolution bandwidth, 8 m device length (accuracies verified using NIST certified artifacts except for IL). High dynamic range option enabled. Averaging Mode: 4 averaged calibration scans, 64 averaged measurement scans, 30 pm resolution bandwidth, 8 m device length (accuracies verified using NIST certified artifacts except for IL). High dynamic range option enabled. *results are typical CLASS 1 LASER PRODUCT