©2022 Advanced Energy Industries, Inc. ARTESYN NPS60-M SERIES 60 W Total Power: 60 W Input Voltage: 90 to 264 VAC 127 to 300 VDC # of Outputs: Single AT A GLANCE SPECIAL FEATURES  Medical and ITE safety approvals  Universal input  Less than 1U high  2" x 4" footprint  Remote sense  Overload and short circuit protection  Adjustable output voltage  High efficiency  High MTBF  Built-in EMI filter (CISPR 22 Class B)  International Efficiency Level V, Energy Star 2.0 (except NPS62-M)  Less than 300 mW no-load power consumption (less than 500 mW for NPS62-M)  0 °C to +80 °C operation  Input power < 74 W  Complies with EN61000-3-2  UL Class I approved  Class II approved (with Class A EMI)  LPX100 enclosure kit available  Dual AC fuses  RoHS compliant SAFETY  TUV 62368-1, 60601-1  UL 62368-1, 60601-1  CSA 62368-1, 60601-1  NEMKO 62368-1, 60601-1  CB Certificate and report  CE Mark (LVD)  CCC Mark  UKCA Mark Advanced Energy's Artesyn NPS60-M series of open-frame AC-DC power supplies comprises four single output models, offering voltages of 5 V, 12 V, 15 V or 24 V. All four models feature ITE and medical safety approvals and are equipped with dual AC fuses. The power supplies have a a typical full load efficiency of 87% and a no-load power consumption of less than 300 mW. The series is primarily designed for use in information technology equipment (ITE) and light industrial systems, as well as for equipment intended for non-patient contact and non-patient critical use in low power medical, dental and laboratory applications.

2 advancedenergy.com NPS60-M ELECTRICAL SPECIFICATIONS Input Input ra nge 90 to 264 VAC or 127 to 300 VDC Frequency 47 to 63 or 440 Hz, safety rating 50/60 Hz Inrush current < 50 A peak @ 230 VAC, cold start @ 25° C Input power < 74 W Efficiency 87% average, as per Energy Star 2.0 standard. (NPS62-M, 80%) EMI/RFI FCC Class B conducted, CISPR 22 Class B conducted, EN55022 Class B conducted, VDE0878PT3 Class B conducted Safety ground leakage current 275 µA @ 50/60 Hz, 264 VAC input Output Maximum power 60 W for convection Adjustment range ± 20% minimum Hold-up time 13/75 ms, 115/230 VAC input line Overload protection Short circuit protection on all outputs. Case overload protected @ 110 to 160% of normal rating Overvoltage protection 130 to 150% of nominal output Remote sense Compensated for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 80 °C, -20 °C start up Storage temperature -45 °C to +85 °C Electromagnetic susceptibility Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating, non-condensing 10% to 90% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated > 550,000 hours at full load and 25 °C ambient conditions

advancedenergy.com 3 NPS60-M MECHANICAL DRAWING BARCODE SERIAL LABEL GND TAB (CN1) PIN 1 PIN 3 SK1 MODEL LABEL ROHS LABEL 0.16” (4.0) MOUNTING HOLE (4 PLACES) 4.00" (101.6) 3.73" (94.6) PIN 1 PIN 6 SK2 1.72" (43.8) 2.00" (50.8) 0.87" (22) NPS62-M 1.14” (29) M2 6 PIN OUTPUT CONNECTOR (SK2) 1.01" (26) INPUT CONNECTOR (SK1) VR1 OUTPUT VOLTAGE ADJUST POT 0.197” (5.0) MINIMUM STANDOFF HEIGHT

4 advancedenergy.com NPS60-M PIN ASSIGNMENTS Connector NPS62-M NPS63-M NPS64-M NPS65-M SK1-1 Line Line Line Line SK1-3 Neutral Neutral Neutral Neutral CN1 Ground Ground Ground Ground SK2-1 +5 V +12 V +15V +24 V SK2-2 +5 V +12 V +15V +24 V SK2-3 Common Common Common Common SK2-4 Common Common Common Common SK2-5 -Sense -Sense -Sense -Sense SK2-6 +Sense +Sense +Sense +Sense MATING CONNECTORS AC Input Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Artesyn Embedded Power Connector Kit #70-841-006 includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5 mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. For DC input an external DC safety rated fuse must be used 7. Warranty: 2 year 8. Weight: 0.26 lbs/0.118 kg

ORDERING INFORMATION

Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Peak Load Regulation

2 Ripple

P/P (PARD) NPS62-M 5 V 0 A 11 A 13 A ± 2% 50 mV NPS63-M 12 V 0 A 5 A 5.5 A ± 2% 120 mV NPS63-M-006 4 12 V 0 A 5 A 5.5 A ± 2% 120 mV NPS64-M 15 V 0 A 4 A 4.4 A ± 2% 150 mV NPS65-M 24 V 0 A 2.5 A 2.75 A ± 2% 240 mV 1. Peak current lasting <15 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. Compliant to Level VI efficiency. 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users.

ENG-NPS60-M-235-01 4.20 For international contact information, visit advancedenergy .com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. Specifications are subject to change without notice. Not responsible for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc.