Isolated 10W Single Output DC-DC Converters www.cdpoweronline.com SELECTION GUIDE

FEATURES

■ High Efficiency to 86% ■ Power Density up to 1.5kW/L (24W/in3 ) ■ 1.5kV Input to Output Isolation ■ Industry Standard Pinout ■ Surge Rating to 12W ■ Non Latching Current Limit ■ Fixed Frequency ■ Versatile Control Options ■ Continuous Rating to 10W at 72°C Without Heatsink ■ Operation to Zero Load ■ Protected Against Load Faults ■ Internal Over Temperature Protection ■ Uses No Electrolytic Capacitors ■ UL 94V-0 Package Materials

DESCRIPTION

The NPH10S series of DC-DC Converters combines ease of application with versatility. The pin pattern is based on the popular industry standard, but two additional pins may optionally be fitted to provide a variety of features not commonly found on units of this type. High efficiency enables full rating to be achieved in a small package without heatsinking. Thermally protected against sustained overload. The copper case achieves efficient heat transfer and screening. The product range has been recognised by Underwriters Laboratory (UL) to UL 1950 for operational insulation, file number E179522 applies. Nominal Output Output Current Max Load Input Voltage Voltage Current Limit 2 (Typ) Efficiency Capacitance Order Code1 (V) (V) (A) (A) (%) (µF) NPH10S2403i 24 3.4 2.94 4.5 79 470 NPH10S2405i 24 5.1 1.96 3.0 83 470 NPH10S2412i 24 12.1 0.83 1.2 86 100 NPH10S2415i 24 15.1 0.67 1.1 86 47 NPH10S4803i 48 3.4 2.94 4.1 80 470 NPH10S4805i 48 5.1 1.96 2.8 83 470 NPH10S4812i 48 12.1 0.83 1.2 86 56 NPH10S4815i 48 15.1 0.67 1.0 87 22 Parameter Conditions MIN NOM MAX Units Voltage Range Continuous operation, 24V input types 18 24 36 V Continuous operation, 48V input types 36 48 75 V Parameter Conditions MIN TYP MAX Units Voltage Set 50% load after 30 mins at nominal 0.5 %Point Error supply voltage Overall Case temperature –40°C to 110°C Voltage Error Load 0% - 100% 1 2.5 % Input specified range Temperature Coefficient Over any 10°C span within theof Output Voltage specified temperature range 50 250 ppm°C (slope) Deviation of Output Voltage Specified over temperature MIN-MAX 0.5 1 % Line Regulation Operating voltage range, 50% load 0.05 0.1 % Load Regulation 0% - 100% rated load 4 0.5 % Ripple rms 70 mV Input voltage, 24V input types –0.5V to 40V 6 Input voltage, 48V input types –0.5V to 80V 6 Output Voltage –0.3V to controlled output voltage (operating or non-operating) Output trim control –1V to +30V Synchronisation/shutdown control ±15V relative to input return INPUT CHARACTERISTICS OUTPUT CHARACTERISTICS Parameter Conditions MIN TYP MAX Units Voltage Trimming At rated load, ±10 %Range Trim control at either output Remote Switch Input5 Not operating -15 0 1.5 V(voltage relative to input negative) Operating, open circuit voltage 9 10 11 Start Delay Time from application of valid input voltage to output being in specification 25 mS Synchronisation5 Specified drive signal 320 440 kHz Switching Frequency 330 350 395 kHz CONTROL CHARACTERISTICS ABSOLUTE MAXIMUM RATINGS ISOLATION CHARACTERISTICS Parameter Conditions MIN TYP MAX Units Isolation Voltage Flash tested for 1 second 1500 VDC Resistance Viso=500VDC 1 G Ω Capacitance 3.3V and 5V output 50 pF 12V and 15V output 90 1 If optional pins ADJ and SS are required (as indicated in the pin connections diagram) prefix the ending “i” with an E when ordering, e.g. NPH10S4803Ei. 2C urrent is quoted when output is 95% of regulated voltage. 3 For applications requiring UL1950 recognition, input voltage must not exceed 60VDC. 4A minimum load of 10% of rating is recommended for typical applications ; see application notes. 5 Optional - Where fitted. 6 Absolute maximum value for 30 seconds. Prolonged operation may damage the product. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.

Isolated 10W Single Output DC-DC Converters C&D Technologies (NCL) Ltd Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545 email: info@cdtechno-ncl.com www.cdpoweronline.com C&D Technologies Inc.

3400 E Britannia Drive, Tucson,

Arizona 85706, USA Tel: +1 (800) 547-2537 Fax: +1 (520) 741-4598 email: sales@cdtechno.com C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use. For information and instructions on use, please consult the NPH SERIES APPLICATION NOTES. © C&D Technologies (NCL) Limited 2003 NDC NPH10S.6 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited. Instructions for use are available from www.cdpoweronline.com ENVIRONMENTAL Parameter Conditions MIN TYP MAX Units Case Temperature Full load –40 110 °C Storage Absolute MAX internal temperature –40 125 °C Relative Humidity Non condensing 85°C 85 % Thermal Protection Operates at case temperature 110 °C Weight: 22g All dimensions in Inches (mm) ± 0.01 (0.25) All pins on a 0.10 (2.54) pitch and within ± 0.01 (0.25) of true position * Optional pins Case connected internally to 0V pin 0.8 20.32 0.98 25.00 0.80 (20.32) 0.15 (3.70) 0.39 (9.96) 0.23 (5.84) 0.2 (5.08) THERMAL CHARACTERISTICS THERMAL PERFORMANCE MAX power rating with case temperature maintained by external means (eg forced air cooling) Case Temperature Part Number 100°C 105°C 110°C Units NPH10S2403 10 7.0 2.3 NPH10S2405 10 8.2 3 NPH10S2412 10 9.5 4 W NPH10S2415 12 9.5 4 NPH10S4803 10 7.0 1 NPH10S4805 10 4.7 1 NPH10S4812 12 8.0 0 W NPH10S4815 12 7.5 0 MECHANICAL DIMENSIONS -40 -20 0 20 40 60 80 100 120 Ambient Temperature (°C) 2412 2415 2405 2403 Output Power (W) -40 -20 0 20 40 60 80 100 120 Ambient Temperature (°C) Output Power (W) 4815 4812 4805 4803 SS +VIN -VIN +VOUT ADJ 0.2 (5.08) BOTTOM VIEW 0.09 (2.34) 0.2 (5.08) Ø 0.04 (1.04) 0.04 (0.90) 1.26 (32.00)