NHB6-0 PATLITE | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
Drawing No. Rev. Page NHB6-3-W18 F SPECIFICATIONS Product Name : Network Signal Tower
[Tolerance ±10%] Withstand Voltage Environmental Condition Storage Ambient Temperature 2 tiers 1 tier 0 tiers Model Operating Ambient Temperature Mounting Location LR6-E-RZ, RY, RG, RB, C LR4-E-RZ, RY, RG, RB, C Wall Mounting Bracket NH-001 LR6-E-R, Y, G, B, MZ 1500VAC applied for 1min (10mA or less) between live part and non-current carrying metallic part without breaking insulration Ethernet (Conforms to the IEEE 802.3) 10BASE-T / 100BASE-TX / 1000BASE-T (Auto MDI / MDI-X) Wireless Data Acquisition System Transmitter WDT-6LR-Z2 Wireless Data Acquisition System Transmitter Optional Parts Partition Mounting Bracket NH-002 AC Adaptor ADP-001 WDT-4LR-Z2 NHB4 Compatible Unit (Optional) LR4-E-R, Y, G, B LED Unit Accessories AC Adaptor*1 , Adhesive sheet NHB6 IPv4 / IPv6 dual stack Interface USB2.0/1.1 Type-A 1ch Outer Dimensions Refer to the Outer Dimension Drawing IP Network 635g + (35g) x Signal Tower Tiers (AC Adaptor not included)NHB4 Communication Method 1. General Specifications Front direction from the center, at 1m, Maximum volume setting 645g + (60g) x Signal Tower Tiers (AC Adaptor not included)NHB6 Insulation Resistance More than 10Mohm at 500VDC between live part and non-current carrying metallic part Sound Pressure Level Main Unit*2 LED Unit 80dB or more (at 25 ℃) Indoor Only Mounting Direction Upright Protection Rating IP 20 21.6 - 26.4VDC 90 - 264VAC -10 - 60℃ (No Dew or Condensation) Storage Ambient Humidity 20%RH - 80%RH (No Dew or Condensation) 1.0W (per Unit, with AC Adaptor, 100VAC input) 0 - 40℃ (No Dew or Condensation) Operating Ambient Humidity 20%RH - 80%RH (No Dew or Condensation) Rated Power Consumption Standby: 110mA Maximum: 155mA (24VDC input) 40mA (per Unit) DC Jack AC Adaptor*1 Standby: 3.2W Maximum: 4.4W (with AC Adaptor, 100VAC input) Rated Current Consumption Main Unit*2 LED Unit Operating Voltage Range DC Jack NHB □-5□ NHB □-4□ NHB □-3□ NHB □-2□ 5 tiers Input: 100 - 240VAC (50/60Hz) Output: 24VDC NHB □-0□ 24VDC 4 tiers 3 tiers LED Unit Rated Voltage Drawing No. Rev. Page NHB6-3-W18 F NHB □-1□ AC Adaptor*1
2.1. Model Number Configuration EN 55032(Class A), EN 55035, EN IEC 63000 ・Conforms to the CE Requirements ・Conforms to the UKCA Requirements (KS C 9610p6p4, KS C 9610p6p2) *3 Remark *1 N type excluded *2 This value excludes USB current consumption. *3 Only N type ・UL/cUL Listed NHB4p0 2. Model UL 62368p1, CSA C22.2 No.62368p1 2.2. Model Number List FCC Part 15 Subpart B(Class A), ICESp003(Class A) Drawing No. Rev. Page NHB6-3-W18 F Conformity Standards NHB4p2pRY NHB6p2pRY NHB6p0N NHB4p4pRYGB NHB6p1pR NHB6p4pRYGB NHB6p1pY NHB6p1pG NHB4p3pRYG NHB4p1pG NHB6p0 NHB6p3pRYG NHB4p0N NHB4p3NpRYG NHB6p5pRYGBC NHB6p3NpRYG NHB4p1pR NHB4p2pRG NHB6p2pRG NHB4p1pY NHB4p5pRYGBC Signal Tower Type Signal Tower Tiers AC Adaptor LED Unit Color From top to bottom LR6(φ60) 0 0 tiers Blank AC Adaptor included N H B □ p Red
4 LR4(φ40) 1 1 tier N AC Adaptor not included Y
R Blue 4 4 tiers C White Amber 2 2 tiers G Green
PLC Information Write Command Protocol SLMP (The same format as the QnA compatible 3E and 4E frame of MC protocol) FINS TCP / UDP "Clear"Button Clear operation is possible with "Clear" Button of the main unit Socket Communication Controllable with PNS Command and PHN Command SNMP Command Controllable with SNMP "set" Command Version v1 / v2c / v3 RSH Command Controllable with RSH Command SSH Command Controllable with SSH Command HTTP Command Controllable with HTTP Command Protocol HTTP, HTTPS Authentication protocol Basic Access Authentication, Digest Access Authentication, none 4. Function Specification 4.1. Main Unit Control Function Method GET When ”Clear operation" occurs, PLC Write Command can be executed. Number of notifications Version v1 / v2c / v3 HTTP Notification When an event occurs, HTTP command is executed. Number of notifications 8 Authentication protocol SMTP certification(Password, OAuth2), POP authentication Security SSL/TLS, STARTTLS, none When an event occurs, Trap or Inform is executed. Number of notifications 8 3.2. Information (Network) When an event occurs, an e-mail message is transmitted Number of notifications 8 Buzzer pattern 3 ON(200ms), OFF(50ms), ON(200ms), OFF(550ms) (repetition) Buzzer pattern 4 ON(continuity) Buzzer pattern 5 ON(1000ms), OFF(1000ms) (repetition) Flashing pattern 4 ON(1000ms), OFF(1000ms) (repetition) 5 kinds of buzzer sounds Buzzer pattern 1 ON(250ms), OFF(250ms) (repetition) Buzzer pattern 2 ON(500ms), OFF(500ms) (repetition) 3. Action Specification 3.1. Information (Main Unit) Lighting, Flashing pattern, and off lighting can be controlled for each LED. Flashing pattern 1 ON(500ms), OFF(500ms) (repetition) Flashing pattern 2 ON(80ms), OFF(170ms), ON(80ms), OFF(670ms) (repetition) Flashing pattern 3 ON(250ms), OFF(250ms) (repetition) Drawing No. Rev. Page NHB6-3-W18 F 4/10
*1 It can be used when e-mail or SNMP is set to "Active" in the RSH/SSH Command Configuration. *2 Signal Tower "Red", "Amber" and "Green", and Flashing pattern 1 *3 Buzzer pattern1 and Buzzer pattern2 *4 It is possible to stop only the buzzer while maintaining the state of Signal Tower. ✓ ✓ ✓ PLC Information Write Command Executable action at detection Signal Tower ✓ ✓ ✓ ✓ Buzzer e-mail SNMP ✓ ✓ MQTT PLC Information Read Command Number of Monitoring 16 Transmission Interval 10ms / 50ms / 100ms Protocol SLMP (The same format as the QnA compatible 3E and 4E frame of MC protocol) FINS TCP / UDP SNMP Supported ✓ ✓ ✓ SNMP Trap Reception Ping Monitoring Monitoring INTEGER, OCTET STRING (String data, Binary data) Detection that the acquired value has changed INTEGER Detectable Type Change Detection Detectable Type PLC Information Read Command Detects the state change of the device information of the PLC HTTP Monitoring Cycle 1 - 60 seconds Detection method Condition Agreement Detection : 20 Change Detection : 5 Dtection that the acquired value meets the conditionCondition Agreement Detectable Type INTEGER, OCTET STRING (String data, Binary data) SNMP Supported Equipment For SNMP Supported equipment, with SNMP command, Version v1 / v2c / v3 their status can be acquisitioned periodically and monitored.Monitor Function SNMP Trap Reception Function Trap Reception detection Version v1 / v2c / v3 Number of Reception 64 variable-bindings 2 OID per 1 Trap Reception Monitoring Cycle 1 - 600 seconds Sending Count The number of times to detect can be set from 1 to 30. Number of Sending The number of sending Ping by one monitoring can be set from 1 to 3. 4.2. External Monitoring Function Ping Monitoring Function Network abnormality detection by sending Ping network devices Number of Monitoring 24 Number of Group 3 SNMP Command ✓ ✓ - - - PHN △*2 △*3 - - -Socket PNS ✓ ✓ - - HTTP Command ✓ ✓ - - - e-mail SNMP HTTP Controllable Action Command Signal Tower Drawing No. Rev. Page NHB6-3-W18 F Buzzer
4.3. Main Unit Status Acquisition Function *1 Signal Tower "Red", "Amber" and "Green", and Flashing pattern 1 *2 Buzzer pattern 1 and Buzzer pattern 2 *1 Light reduction is not possible when using LR4/6-E-MZ or WDT-4/6LR-Z2. *2 Google Chrome is a trademark or registered trademark of Google LLC. *3 Microsoft Edge is registered trademark of Microsoft Corporation in the United States and other countries. Drawing No. Rev. Page NHB6-3-W18 F RSH Command The state of the main body can be acquired by the status acquisition command. SSH Command The state of the main body can be acquired by the status acquisition command. Socket Communication Status acquisition available with PNS Command and PHN Command SNMP Command Status acquisition available with SNMP "get" Command Version v1 / v2c / v3 HTTP Communication The state of the main body can be acquired in XML/JSON data format. Acquisition data Command Signal Tower Buzzer RSH Command ✓ ✓ SSH Command ✓ ✓ Socket PNS ✓ ✓ PHN ✓*1 ✓*2 Automatic Network Setting SNMP Command ✓ ✓ XML/JSON format file ✓ ✓ Self test of Signal Tower and buzzer is possibleSelf-test Function
4.4 Main Unit Setting Function
The internal clock in this product can communicate with an NTP server to automatically set. Buzzer Volume Setting Master Volume of Buzzer can be set to automatically correct the time.Time Correction Function Network setting in this product can communicate with an DHCP server USB Flash Drive Function USB flash drive can be used to read and written configuration files, update firmware, and download Event logs. Flash Control Setting The brightness of the LED unit can be reduced.*1 Standard Action Setting The color of Signal Tower that lights up after the clear operation is executed can be set. with test button of the main body and RSH/SSH command. Config Setting Various settings of the main body can be read and written as setting file. Languages supported on the setting screen Japanese, English, Traditional Chinese, Sinplified Chinese, Korean, Thai German, French, Italian, Spanish, Mexican Event Log Event logs can be downloaded via web browser and USB flash drive. Main Unit Setting Various settings of the main body can be done with a web browser. Supported browsers Google Chrome *2 Microsoft Edge *3
*1 Microsoft Azure is registered trademark of Microsoft Corporation in the United States and other countries. *2 Amazon Web Services, the "Powered by AWS"logo, and any other AWS trademarks used in such materials are trademarks of Amazon.com, Inc. or its affiliates in the United States and other countries. Built-in features Connection Settings Built-in features Main Unit Control Signal Tower, Buzzer Main Unit Status Acquisition Signal Tower, Buzzer Main Unit Status Transmission Built-in features, "Clear" button Cloud-to-device Message AWS IoT Core Device Shadow, MQTT client Azure AWS Connection Settings Device Twin, Direct Method, Device-to-cloud Message, 4.5. Cloud Function Supported Cloud Platform Microsoft Azure *1 Amazon Web Services (AWS) *2 Azure IoT Central/DPS, Azure IoT Hub (IoT Plug and Play) Drawing No. Rev. Page NHB6-3-W18 F 7/10
NHB6 (Unit: mm) Drawing No. Rev. Page NHB6-3-W18 F No. Parts name Material Color Number of LED L
1 Head Cover PC Off-white 0 tiers 150
2 LED Unit PC Clear 1 tier 190
3 Main Body ABS Off-white/Medium Gray 2 tiers 230
NHB4 (Unit: mm) Drawing No. Rev. Page NHB6-3-W18 F No. Parts name Material Color Number of LED L
(Unit: mm) Drawing No. Rev. Page NHB6-3-W18 F