NAC-10-472 POWERBOX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Features
- High-attenuation type of common mode noise from 150kHz to 1MHz. Single Phase 250Vac. Selectable leakage current. Quick and easy push down terminal. Din rail installation type (Option).
Ordering Information
- Model name
2 Rated current
- Line to ground capacitor code 4. Options D: Din rail installation type. CODE CURRENT 06 6A 10 10A 16 16A 20 20A 30 30A CODE LEAKAGE CURRENT(INPUT 125/250V 60HZ) LINE TO GROUND CAPACITOR(NOMINAL VALUE) 681 75.5mA / 150mA max 680pF 102 0.13mA / 0.25mA max 1000pF 222 0.25mA / 0.5mA max 2200pF 332 0.38mA / 0.75mA max 3300pF 472 0.5mA / 1.0mA max 4700pF When the line to ground capacitor code is different, the attenuation characteristic is different. NAC -10 -472 _ (1) (2) (3) (4)