Présente / Presents:
Mounting (Bottom view) 38.1 22.78 16.4 7.62 22.2 1 2 3 4 5 6 7 8 9 38.138.1 22.78 16.4 7.62 22.2 1 2 3 4 5 6 7 8 9 9- 2.7 2- 1.8 N375 73.7 54.1 35.6 heavy reverse power 30A/300VAC 28VDC Optional mounting ways. Firm structure, strong anti-shock & anti vibration. Suitable for automatic control, household electrical appliances and machinery electrical facilities.
Features
Ordering Information
1 Part number N375 4 Coil rated voltage DC:6,12,24,48,110
2 Contact arrangement 3A:3A 3B:3B 3C:3C AC: 6,12,24,48,120,208,240
3 Terminal a: inserting type b: PCB type 5 Cover F:F mode; P:P mode; TM:TM model
3A (3PSTNO) 3B (3PSTNC) 3C (3PDT (B-M))Contact Arrangement Contact Material AgCdO AgSnO 2 Contact Rating (Resistive) Max. Switching Power Max. Switching V oltage Max. Resistance or Voltage drop 50m Item 3.12 of IEC255-7 Mechanical 1 10 Item 3.31 of IEC255-7 3A,3B,3C:30A/300VAC,28VDC; 2HP 240V AC , 1HP 120VAC 900W 9000V A 150VDC 380V AC Max. Switching Current:30A Pick up voltage V(max) 85%of rated voltage Release voltage V(min) 20%of rated voltage COIL POWER Operate Time ms Release Time msRated Max. AC Coil Parameter 006AC 012AC 024AC 048AC 120AC 208AC 240AC 006-2600 012-2600 024-2600 048-2600 110-2600 120 208 240 110 6.6 13.2 26.4 52.8 132 229 264 6.6 13.2 26.4 52.8 121 2.4 9.5 150 570 3075 3800 230 900 4900 Operation life al DC 75%o f rated voltage 10%o f rated voltage 5.1 10.2 20.4 40.8 102.0 176.8 204.0 4.5 9.0 18.0 36.0 82.5 4.5VA 1.2 2.4 4.8 9.6 24.0 41.6 48.0 0.6 1.2 2.4 4.8 11.0 2.6W 15 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Dash numbers Rated voltage V Coil resistance 10% N375 Insulation Resistance 100M min (at 500VDC) Item 7 of IEC255-5 Dielectric Strength Between contacts Between contact and coil Shock resistance 100m/s 11ms Vibration resistance 10~55Hz double amplitude 1.5mm IEC68-2-6 Test Fc Terminals strength 8N I EC68-2-21 T est U a2 Solderability 235 2 3 0.5s I EC68-2-20 T est T a m ethod 1 Ambient Temperature -25~60 Relative Humidity 85% (at 40 ) I EC68-2-3Test C a Mass 99g Item 8 of IEC255-5 Operation condition 50Hz 2200V 50Hz 3750V Item 6 of IEC255-5 IEC68-2-27 Test Ea Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions Dimensions Wiring diagram (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only . 4 5 6 7 8 9 1 2 3 7 8 9 1 2 3 4 5 6 7 8 9 3A 3B 3C mm /inch 0.098 0.071 0.055 0.032 0.625 0.874 0.874 0.071 0.071 1.500 1.500 0.897 0.646 0.300 0.897 0.646 0.300 2.350 0.156 0.250 0.031 0.059 1.898 2.500 2.900max. 0.079 0.150 0.090 0.032 2.130max. 1.400 max. 2.350max. 0.062 0.170 3.160max. 2.750 Max.Max. Max. Max. Max. E160644C US Safety approvals Safety approval UL&CUR Load 30A/300VAC 2HP240VAC 1HP120VAC Ningb o Huaguan Relay Corporation LTD. NHG RELAYS