Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 1 of 6 www.murata-ps.com For full details go to www.murata-ps.com/rohs Ḥ www.murata-ps.com SELECTION GUIDE Order Code1 Nominal Input Voltage Output Voltage Output Current Load Regulation (Typ.) Load Regulation (Max) Ripple & Noise (Typ.)3 Ripple & Noise (Max.)3 Input Current at Full Load Effi ciency (Min.) Effi ciency (Typ.) Isolation Capacitance MTTF2 VV m A % mVp-p mA % % pF kHrs MTU1S0505MC 5 5 200 7.3 9 35 60 241 80 83 19 5664 MTU1S0509MC 5 9 111 6.1 7.5 15 25 233 83 86 20 5488 MTU1S0512MC 5 12 83 5.6 7.5 15 25 230 84 87 21 5186 MTU1S0515MC 5 15 67 5.3 6.5 15 25 230 84 87 22 4773 MTU1S1205MC 12 5 200 5.6 8 20 40 99 80 84 22 5641 MTU1S1209MC 12 9 111 3.9 6 15 25 96 82 87 31 5467 MTU1S1212MC 12 12 83 3.5 6 10 25 95 83 88 40 5165 MTU1S1215MC 12 15 67 3.2 5 10 25 95 84 88 35 4753 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Refl ected ripple current 5V input types 6 mA p-p12V input types 5 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation voltage Flash tested for 1 second 1000 VDC Resistance Viso= 1000VDC 10 GΩ GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency 5V input types 82 kHz12 input types 90 ABSOLUTE MAXIMUM RATINGS Input voltage VIN, MTU1S05 types 7V Input voltage VIN, MTU1S12 types 15V OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated power T A=-40°C to 85°C 1.0 W Voltage set point accuracy See tolerance envelope Line regulation High V IN to low VIN 1.0 1.1 %/% TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specifi cation All output types -40 85 °CStorage -55 125 Case temperature rise above ambient4 All types 12 Cooling Free air convection 1. If components are required in tape and reel format suffi x order code with -R, e.g. MTU10505MC-R. 2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load. 3. See ripple & noise characterisation method. 4. Measured after 1 hour continuous operation at nominal V IN full load at the center of each PCB. All specifi cations typical at T A=25°C, nominal input voltage and rated output current unless otherwise specifi ed.
FEATURES
Patent Pending Footprint over pins 0.69cm2 Single isolated output 1kVDC Isolation Effi ciency up to 88% (Typ.) MSL Level 1 Power density 1.71W/cm3 Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 94V-0 Package material 5V & 12V Input 5V, 9V, 12V & 15V output Toroidal magnetics Custom solutions available Multi-layer ceramic capacitors PRODUCT OVERVIEW The MTU1 series is a new range of miniature surface mount, high performance 1W DC/DC converters. With a footprint reduction of over 50% from the previous generation of 1W SMD DC/DC, the MTU1 series offers 1W of available output power over the full industrial temperature range of -40ºC to 85ºC. The MTU1 series is more effi cient and offers improved regulation performance for applications where a wide output voltage variation can not be tolerated. The devices are suitable for all applications where high volume production is envisaged.
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 2 of 6 www.murata-ps.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MTU1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specifi c agency approvals, such as the MTU1 series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The MTU1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. 1. Measured on centre of input side PCB. TEMPERATURE DERATING GRAPH 150100500-40 0.5 1.0 1.5 Safe Operating Area 85°C Ambient Temperature (°C) Output Power (W) RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak refl ow solder temperature of 245ºC as per J-STD-020D. The pin termination fi nish on this product series is Matte Tin over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1. Samples of the product series were tested in accordance with the conditioning described for MSL level 1 in IPS/JEDEC STD-020D. The product series passed electrical tests and visual inspection criteria. For further information, please visit: www.murata-ps.com/rohs TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. Output Load Current (%) egatloV tuptuO VNOM -4% 100755025 10 Output Load Current (%) egatloV tuptuO VNOM 5.5% -4% 1.5% 100755025 10 5V output types All other types
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 3 of 6 www.murata-ps.com APPLICATION NOTES Minimum load The minimum load to meet datasheet specifi cation is 10% of the full rated load across the specifi ed input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specifi ed output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test confi guration. C1 1μF X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon fi lm, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specifi ed values. Differential Mode Noise Test Schematic OSCILLOSCOPE Y INPUT SUPPLY C1 C2 C3 R1 T1 R2 Input Output DC/DC Converter R LOAD + + - - Typical Start-Up Wave FormStart-up time ms MTU1S0505MC 0.9 MTU1S0509MC 2.7 MTU1S0512MC 4.3 MTU1S0515MC 7.5 MTU1S1205MC 0.9 MTU1S1209MC 1.9 MTU1S1212MC 3.3 MTU1S1215MC 4.7
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 4 of 6 www.murata-ps.com APPLICATION NOTES (continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. EFFICIENCY VS LOAD MTU1S05xxMC MTUS12xxMC DC DC L C LoadPower Source Inductor Capacitor L, μH SMD Through Hole C, μF MTU1S0505MC TBD MTU1S0509MC MTU1S0512MC MTU1S0515MC MTU1S1205MC MTU1S1209MC MTU1S1212MC MTU1S1215MC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Efficiency (%) 12V 15V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Efficiency (%) 12V 15V
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 5 of 6 www.murata-ps.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS - Patent Pending PIN CONNECTIONS Pin Function 1+ V IN 3- V IN 4+ V OUT 5O V 6N C RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS Unless otherwise stated all dimensions in mm±0.25mm (inches). Tube length: 520mm ±2.00 Tube Quantity: 60 S 1.80±0.2 (0.071) x5 PINS 0.25±0.1 (0.01) c 0.10 (0.004) S 0.35 (0.014) (Typ.) 2.54 (0.100) 8.20 (0.323) 5.08 (0.200) 0.60±0.1 (0.024) 1.56 (0.061) 8.50 +0.00 -0.008 ) 1.80±0.2 (0.071) SEATING PLANE 12.25 (0.482) MAX 12.25 (0.482) MAX 6.50 (0.256) 2.54 (0.100) 2.54 (0.100)
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 MTU1 Series Isolated 1W Single Output SM DC/DC Converters 2011-02-01 KDC_MTU.A03 Page 6 of 6 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2011 Murata Power Solutions, Inc. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED www.murata-ps.com/locations TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS TAPE OUTLINE DIMENSIONS REEL PACKAGING DETAILS Product Orientation Pin 1, located nearest to carrier drive sprocket. Reel Quantity: 300 pcs. DIRECTION OF UNREELING 16.00±0.10 (0.630) 11.50±0.1 (0.453) 1.75±0.1 (0.069) 2.00±0.1 (0.079) 4.00±0.1 (0.157) 9.00±0.1 8.50±0.1 (0.335) 8.70±0.1 (0.343) 0.50±0.05 (0.020) TRAILER SECTION 160 (6.30) MIN LEADER SECTION 400 (15.75) MIN CARRIER TAPE START 100 (3.94) MINGOODS ENCLOSURE SECTION XWWYY XWWYY XWWYY MTU1S 0509 MTU1S 0509 MTU1S 0509 330 (12.99) MAX 100 (3.94) MIN 13.00±0.25 (0.51±0.009) 30.40 (1.20) MAX (AT HUB SECTION) Ø Ø -0.00 (0.00)