Features
Full-featured AHRS on 12.1 x 12.1 mm module Roll/pitch accuracy (dynamic) 1.0 deg Heading accuracy 2.0 deg Minimal requirements on host processor Uniform interface over product lifetime o No hardware/software interface changes o No EOL Always best-in-class inertial sensors incorporated Industry-leading signal processing pipeline (AttitudeEngineTM) with vibration-rejection Robust and accurate orientation algorithm (XKF3TM) API-compatible with all Xsens’ Motion Trackers o Drivers and examples on ARM® mbedTM Low power (45 mW @ 3.0V)
Applications
Miniature aerial vehicles Heavy machinery/agriculture Robotics, pedestrian dead-reckoning Industrial grade VR/AR, HMD’s and handheld devices Related Resources www.xsens.com/MTi-1-series MTi 1-series DK User Manual (MT0513P) MT Low Level Communication Protocol Documentation (MT0101P) MTi White Paper: Next generation Xsens Motion Trackers for Industrial applications
Description
The MTi 1-series is a module outputting 3D orientation, 3D rate of turn, 3D accelerations, and 3D magnetic field, depending on the product configuration . It is available as an Inertial Measurement Unit (IMU), Vertical Reference Unit (VRU) or Attitude and Heading Reference System (AHRS). This full y-functional self-contained module is easy to design in with limited hardware components to be added. The fully d ocumented, industry -standard communication protocol allows for customization of the data message in terms of data, frequency and output format. Signals are fully processed onboard, requiring very little resources from the host and is very well suited for applications in simple MCU-operated environments. The host can read-out the data over SPI, I2C or UART. With a roll/pitch accuracy of 1. 0º RMS and yaw accuracy of 2º RMS under dynamic conditions, the output is excellent for control and stabilization of any object and navigation of e.g. unmanned vehicles. Figure 1: MTi 1-series Product Output MTi-1 IMU MTi-2 VRU MTi-3 AHRS Motion data ● ● ● Magnetic field ● ● ● Roll/pitch ● ● Heading tracking ● ● Referenced yaw ● 3D AHRS/VRU/IMU module Data sheet MTi 1 -series
www.xsens.com 2 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series Table of Contents
www.xsens.com 3 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
1 General information
1.1 Ordering Information
Part Number Output Package Packing Method MTi-1-8A7G6 IMU; inertial data PCB, JEDEC-PLCC-28 compatible Tray, MOQ: 20 MTi-2-8A7G6-TR20 VRU; inertial data, roll/pitch (referenced), yaw (unreferenced) PCB, JEDEC-PLCC-28 compatible Tray, MOQ: 20 MTi-3-8A7G6-TR20 AHRS; inertial data, roll/pitch/yaw PCB, JEDEC-PLCC-28 compatible Tray, MOQ: 20 MTi-3-8A7G6-DK Development kit for MTi 1-series, including MTi-3-8A7G6 Single unit Other packaging methods available on request (>1k units). Contact Xsens for more information.
1.2 Block Diagram
Figure 2: MTi 1-series module block diagram
www.xsens.com 4 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
1.3 Typical Application
1.4 Pin Configuration
Figure 4: Pin assignment Figure 3: Typical application
www.xsens.com 5 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
1.5 Pin map
The pin map depends on the peripheral selection. See section 1.7 on how to set the peripherals. PSEL: I2C PSEL: SPI PSEL: UART half duplex PSEL: UART full duplex
1 DNC DNC DNC DNC
2 DNC DNC DNC DNC
3 DNC DNC DNC DNC
4 GND GND GND GND
5 VDD VDD VDD VDD
7 VDDIO VDDIO VDDIO VDDIO
8 GND GND GND GND
9 DNC SPI_DNCS DNC DNC
10 ADD21 SPI_MOSI DNC DNC
11 ADD1 SPI_MISO DNC DNC
12 ADD0 SPI_SCK DNC DNC
13 GND GND GND GND
14 PSEL0 PSEL0 PSEL0 PSEL0
15 PSEL1 PSEL1 PSEL1 PSEL1
16 SYNC_IN SYNC_IN SYNC_IN SYNC_IN
18 DNC DNC DNC DNC
19 DNC DNC DNC DNC
20 DNC DNC DNC DNC
21 DNC DNC DE RTS
22 DRDY DNC nRE CTS2
23 I2C_SDA DNC UART_RX UART_RX
24 I2C_SCL DNC UART_TX UART_TX
25 GND GND GND GND
26 DNC DNC DNC DNC
27 DNC DNC DNC DNC
28 DNC DNC DNC DNC
1 I2C addresses, see Table 2: List of I2C addresses
2 CTS cannot be left unconnected if the interface is set to UART full duplex. If HW flow control is not used, connect to GND.
1.6 Pin Descriptions
1.7 Peripheral interface selection
value of 1, connecting PSEL to a GND results in a value of 0. Table 1. Peripheral interface selection
1.7.1 I2C
Further specifications TBC, available from November 2015. Table 2. List of I2C addresses
1.7.2 SPI
1.7.3 UART half duplex
shared medium on the RX signal. and nRE and DE lines control the buffers inside the transceiver. When the MTi is transmitting data on its TX pin it will raise both the nRE and DE lines, else it will pull these lines low. Note that in this mode the UART of the MTi 1-series itself is still operating full duplex.
www.xsens.com 8 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
1.7.4 UART full duplex with RTS/CTS flow control
The MTi 1-series module can be configured to communicate over UART in full duplex mode with RTS/CTS flow control. The UART frame configuration is 8 data bits, no parity and 1 stop bit (8N1). In addition to the RX and TX signals for data communication the RTS and CTS signals are used for hardware flow control. The CTS signal is an input for the MTi. The MTi checks the state of the CTS line at the start of every byte it transmits. If CTS is low the byte will be transmitted. Otherwise transmission is postponed until CTS is lowered. When during the transmission of a byte the CTS signal is raised then the transmission of that byte is completed before postponing further output. This byte will not be retransmitted. This behaviour is shown in the following image: Figure 6 Data transmit behaviour under CTS The RTS signal is an output for the MTi. If the RTS line is high, the MTi is busy and unable to receive new data. Otherwise the MTi1’s UART is idle and ready to receive. After receiving a byte the DMA controller of the MTi will transfer the byte to its receive FIFO. The RTS signal will be asserted during this transfer. So with every byte received the RTS line is raised shortly like shown in the following image: Figure 7 RTS behaviour under data reception This communication mode can be used without hardware flow control. In this case the CTS line needs to be tied low (GND) to make the MTi transmit.
1.8 Recommended external components
Component Description Typical value Rpu I2C pull-up resistor 2.7 kΩ RPSEL0 / RPSEL1 Interface selection resistors Up to 5kΩ Notes: - Rpu is only needed when the MTi-1 is configured for I2C interface - RPSEL is only required when interface is not I2C. If the interface does not need to be switched, RPSEL0 and RPSEL1 can be connected directly to GND. Figure 8: External components (I2C interface) Figure 9: External components (UART interface)
www.xsens.com 9 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
2 MTi 1-series architecture
This section discusses the MTi 1-series architecture including the various configurations and the signal processing pipeline.
2.1 MTi 1-series configurations
The MTi 1-series is a fully-tested self-contained module that can 3D output orientation data (Euler angles (roll, pitch, yaw), rotation matrix (DCM) and quaternions), orientation and velocity increments (∆q and ∆v) and sensors data (acceleration, rate of turn, magnetic field). The MTi 1-series module is available as an Inertial Measurement Unit (IMU), Vertical Reference Unit (VRU) and Attitude and Heading Reference System (AHRS). Depending on the product, output options may be limited to sensors data and/or unreferenced yaw. All MTi’s feature a 3D accelerometer/gyroscope combo-sensor, a magnetometer, a high-accuracy crystal and a low-power MCU. The MCU coordinates the synchronization and timing of the various sensors, it applies calibration models (e.g. temperature modules) and output settings and runs the sensor fusion algorithm. The MCU also generates output messages according to the proprietary XBus communication protocol. The messages and the data output are fully configurable, so that the MTi 1-series limits the load, and thus power consumption, on the application processor.
2.1.1 MTi-1 IMU
The MTi-1 module is an Inertial Measurement Unit (IMU) that outputs 3D rate of turn, 3D acceleration and 3D magnetic field. The MTi-1 also outputs coning and sculling compensated orientation increments and velocity increments (∆q and ∆v) from its AttitudeEngineTM. Advantages over a gyroscope- accelerometer combo-sensor are the inclusion of synchronized magnetic field data, on-board signal processing and the easy-to-use communication protocol. Moreover, the testing and calibration performed by Xsens result in a robust and reliable sensor module, that can be integrated within a short time frame. The signal processing pipeline and the suite of output options allow access to the highest possible accuracy at any bandwidth, limiting the load on the application processor.
2.1.2 MTi-2 VRU
The MTi-2 is a 3D vertical reference unit (VRU). Its orientation algorithm (XKF3TM) outputs 3D orientation data with respect to a gravity referenced frame: drift- free roll, pitch and unreferenced yaw. In addition, it outputs calibrated sensor data: 3D acceleration, 3D rate of turn and 3D earth-magnetic field data. All modules of the MTi 1-series are also capable of outputting data generated by the strapdown integration algorithm (the AttitudeEngineTM outputting orientation and velocity increments ∆q and ∆v). The 3D acceleration is also available as so-called free acceleration which has gravity subtracted. Although the yaw is unreferenced, though still superior to gyroscope integration. With the feature Active Heading Stabilization (AHS, see section 7.2) the drift in unreferenced yaw can be limited to 1 deg after 60 minutes, even in magnetically disturbed environments.
2.1.3 MTi-3 AHRS
The MTi-3 supports all features of the MTi-1 and MTi- 2, and in addition is a full gyro-enhanced Attitude and Heading Reference System (AHRS). It outputs drift- free roll, pitch and true/magnetic North referenced yaw and sensors data: 3D acceleration, 3D rate of turn, as well as 3D orientation and velocity increments (∆q and ∆v), and 3D earth-magnetic field data. Free acceleration is also available for the MTi-3 AHRS.
www.xsens.com 10 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
2.2 Signal processing pipeline
The MTi 1-series is a self-contained module, so all calculations and processes such as sampling, coning and sculling compensation and the Xsens XKF3TM sensor fusion algorithm run on board.
2.2.1 Strapdown integration
The Xsens optimized strapdown algorithm (AttitudeEngineTM) performs high-speed dead- reckoning calculations at 1 kHz allowing accurate capture of high frequency motions. This approach ensures a high bandwidth. Orientation and velocity increments are calculated with full coning and sculling compensation. At an output data rate of up to 100 Hz, no information is lost, yet the output data rate can be configured low enough for systems with limited communication bandwidth. These orientation and velocity increments are suitable for any 3D motion tracking algorithm. Increments are internally time- synchronized with the magnetometer data.
2.2.2 XKF3TM Sensor Fusion Algorithm
XKF3 is a sensor fusion algorithm, based on Extended Kalman Filter framework that uses 3D inertial sensor data (orientation and velocity increments) and 3D magnetometer, also known as ‘9D’ to optimally estimate 3D orientation with respect to an Earth fixed frame. XKF3 takes the orientation and velocity increments together with the magnetic field updates and fuses this to produce a stable orientation (roll, pitch and yaw) with respect to the earth fixed frame. The XKF3 sensor fusion algorithm can be processed with filter profiles. These filter profiles contain predefined filter parameter settings suitable for different user application scenarios. The following filter profiles are available: General – suitable for most applications. Supported by the MTi-3 module. Dynamic – assumes that the motion is highly dynamic. Supported by the MTi-3 module. High_mag_dep – heading corrections rely on the magnetic field measured. To be used when magnetic field is homogeneous. Supported by the MTi-3 module. Low_mag_dep – heading corrections are less dependent on the magnetic field measured. Heading is still based on magnetic field, but more distortions are expected with less trust being placed on magnetic measurements. Supported by the MTi-3 module. VRU_general – Roll and pitch are the referenced to the vertical (gravity), yaw is determined by stabilized dead-reckoning, referred to as Active Heading Stabilization (AHS) which significantly reduces heading drift, see also section 7.2. Consider using VRU_general in environments that have a heavily disturbed magnetic field. The VRU_general filter profile is the only filter profile available for the MTi-2-VRU, also supported by the MTi-3 module
www.xsens.com 11 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
2.2.3 Frames of reference used in MTi 1-series
The MTi 1-series module uses a right-handed coordinate system as the basis of the sensor of frame. The following data is outputted in corresponding reference coordinate systems: Data Symbol Reference coordinate system Acceleration ax, ay, az Sensor-fixed Rate of turn ωx, ωy, ωz Sensor-fixed Magnetic field mx, my, mz Sensor-fixed Free acceleration ax, ay, az Local Tangent Plane (LTP), default ENU Velocity increment ∆vx, ∆vy, ∆vz Local Tangent Plane (LTP), default ENU Orientation increment ∆q0, ∆q1, ∆q2, ∆q3 Local Tangent Plane (LTP), default ENU Orientation Euler angles, quaternions or rotation matrix Local Tangent Plane (LTP), default ENU Local Tangent Plane (LTP) is a local linearization of the Ellipsoidal Coordinates (Latitude, Longitude, Altitude) in the WGS-84 Ellipsoid. It is straightforward to apply a rotation matrix to the MTi, so that the velocity and orientation increments, free acceleration and the orientation output is output using that coordinate frame. The default reference coordinate system is East-North-Up (ENU) and the MTi 1-series has predefined output options for North-East-Down (NED) and North- West-Up (NWU). Any arbitrary alignment can be entered. These orientation resets have effect on all outputs that are by default outputted with an ENU reference coordinate system. z x y Figure 10: Default sensor fixed coordinate system for the MTi 1-series module
Table 3. Orientation specifications section 7.2 for more information.
3.2 Sensors specifications3
Table 4. Gyroscope specifications Bias repeatability (1 yr) 0.5 deg/s The bias is continuously estimated by XKF3i. Table 5. Accelerometers specifications
3 As Xsens continues to update the sensors on the module, these specifications may change
Table 6. Magnetometer specifications Table 7. Alignment specifications
www.xsens.com 14 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
4 Sensor calibration
Each MTi is individually calibrated and tested over its temperature range. The (simplified) sensor model of the gyroscopes, accelerometers and magnetometers can be represented as following: 𝑠 = 𝐾𝑇 −1(𝑢 −𝑏𝑇) s = sensor data of the gyroscopes, accelerometers and magnetometers in rad/s, m/s2 or a.u. respectively KT-1 = gain and misalignment matrix (temperature compensated) u = sensor value before calibration (unsigned 16-bit integers from the sensor) bT = bias (temperature compensated) Xsens’ calibration procedure calibrates for many parameters, including bias (offset), alignment of the sensors with respect to the module PCB and each other and gain (scale factor). All calibration values are temperature dependent and temperature calibrated. The calibration values are stored in non-volatile memory in the MTi.
5 System and electrical specifications
5.1 Interface specifications
Table 8. Communication interfaces
21 MHz
Table 9. Auxiliary interfaces
5.2 System specifications
Table 10. System specifications
5.3 Electrical specifications
Table 11. Electrical specifications
5.4 Absolute maximum ratings
4 This is a mechanical shock (g) sensitive device. Proper handling is required to prevent damage to the part. 5 This is an ESD-sensitive device. Proper handling is required to prevent damage to the part.
www.xsens.com 17 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
6 MTi 1-series settings and outputs
The MTi 1-series module uses the Xsens-proprietary Xbus protocol, which is compatible with all Xsens Motion Tracker products.
6.1 Message structure
The communication with the MT is done by messages which are built according to a standard structure. The message has two basic structures; one with a standard length and one with extended length. The standard length message has a maximum of 254 data bytes and is used most frequently. In some cases the extended length message needs to be used if the number of data bytes exceeds 254 bytes. An MT message (standard length) contains the following fields: Xbus header Preamble BID MID LEN DATA CHECKSUM An MT message (extended length) contains these fields: Preamble BID MID LENext LEN DATA CHECKSUM Details on the Xbus protocol message structure can be found in the MT Low Level Communication Protocol documentation (LLCP). Field Field width Description Preamble 1 byte Indicator of start of packet 250 (0xFA) BID 1 byte Bus identifier or Address 255 (0xFF) MID 1 byte Message identifier LEN 1 byte For standard length message: Value equals number of bytes in DATA field. Maximum value is 254 (0xFE) For extended length message: Field value is always 255 (0xFF) EXT LEN 2 bytes 16 bit value representing the number of data bytes for extended length messages. Maximum value is 2048 (0x0800) IND ID 1 byte The type of indication received DATA (standard length) 0 – 254 bytes Data bytes (optional) DATA (extended length) 255 – 2048 bytes Data bytes Checksum 1 byte Checksum of message
www.xsens.com 18 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
6.2 Output settings
The section below only describes the most important set of MTData2 data messages. For all messages supported by the MTi 1-series, refer to the MT Low Level Communication Protocol documentation (LLCP). The Output Configuration message sets the output of the device. Each data message has a DataID which consists of a data type and a number format. The table below shows the most important MTData2 Data identifiers. The message SetOutputconfiguration holds the DataID and the output frequency. SetOutputConfiguration MID 192 (0xC0) DATA OutputConfig (N*4 bytes) Set the output configuration of the device. The data is a list of maximum 32 data identifiers combined with a desired output frequency. The response message contains a list with the same format, but with the values actually used by the device. Each entry in the list contains: Offset Value
0 Data Identifier (2 bytes)
2 Output frequency (2 bytes)
Group Name Type Name XDA type name6 Hex Value Timestamp XDI_TimestampGroup Packet Counter XDI_PacketCounter 1020 Sample Time Fine XDI_SampleTimeFine 1060 Orientation Data XDI_OrientationGroup Quaternion XDI_Quaternion 201y Rotation Matrix XDI_RotationMatrix 202y Euler Angles XDI_EulerAngles 203y Acceleration XDI_AccelerationGroup Delta V (dv) XDI_DeltaV 401y Acceleration XDI_Acceleration 402y Free Acceleration XDI_FreeAcceleration 403y Angular Velocity XDI_AngularVelocityGroup Rate of Turn XDI_RateOfTurn 802y Delta Q (dq) XDI_DeltaQ 803y Magnetic XDI_MagneticGroup Magnetic Field XDI_MagneticField C02y Status XDI_StatusGroup Status Word XDI_StatusWord E020 y: The hex value of the Format bits (see table below). The value is formed by doing a bitwise OR of the available fields 6 XDA: Xsens Device API. Communication protocol in C, to be used on external processors.
www.xsens.com 19 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series Field Format Description Short name Precision 0x0 Single precision IEEE 32-bit floating point number Float32 0x1 Fixed point 12.20 32-bit number Fp1220 0x2 Fixed point 16.32 48-bit number Fp1632 0x3 Double precision IEEE 64-bit floating point number Float64 Coordinate system 0x0 East-North-Up coordinate system ENU 0x4 North-East-Down coordinate system NED 0x8 North-West-Up NWU Example: the DataID for quaternions in NED coordinate system with fixed point 16.32 number format is represented as 0x2016.
6.3 MTData2
Data is represented in the MTData2 message. MTData2 MID 54 (0x36) DATA DATA (length variable) The MTData2 message contains output data according the current OutputConfiguration. An MTData2 message consists of one or more packets, each containing a specific output. The layout of an MTData2 message is shown below: XBus header Packet #1 Packet #2 Packet #N CS Xbus Header Pre- amble BID MID LEN DataID Data LEN Packet Data (Data LEN bytes) 0xFA 0xFF 0x36 .. An example data message is depicted below (explanation of the message, divided into parts, in the table): FA FF 36 35 10 20 02 51 BC 10 60 04 00 21 49 AF 40 10 0C 39 B9 D8 00 B7 DD 80 00 3C C9 26 98 80 30 10 3F 80 00 01 B6 ED 60 01 36 94 A0 00 36 1E 60 00 E0 20 04 00 00 00 87 A0 Part of message (0x) Meaning FA FF 36 35 Xbus Header with total length of message (0x35) 10 20 02 51 BC DataID 0x1020 (Packet counter), length 0x02, data (0x51 BC) 10 60 04 00 21 49 AF DataID 0x1060 (Sample Time fine), length 0x04, data 40 10 0C 39 B9 D8 00 B7 DD 80 00 3C C9 26 98 DataID 0x4010 (velocity increment), length 0x0C, data 80 30 10 3F 80 00 01 B6 ED 60 01 36 94 A0 00 36 1E 60 00 DataID 0x8030 (orientation increment), length 0x10, data E0 20 04 00 00 00 87 DataID 0xE020 (StatusWord), length 0x04, data A0 Checksum
www.xsens.com 20 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
6.4 Synchronization and timing
The MTi 1-series modules can easily be synchronized with other sensors or sensor systems. The MTi accepts a pulse and can then transmit the latest available data. This SYNC_IN functionality does not influence the accuracy of the data as internally the MTi 1-series keeps estimating the orientation at its maximum frequency. Acceleration data and rate of turn data is also outputted with the shortest possible latency. The Sync Settings are set with the SetSyncSettings message: SetSyncSettings MID 44 (0x2C) DATA Setting List (N*12 bytes) Set the synchronization settings of the device. Settings Each setting describes either a system event that should trigger a sync in event that should trigger a system action. SYNC_IN setting Offset (bytes) Setting Size (bytes)
0 Function 1 Value 8: Send Latest
1 Line 1 Value 2: SYNC_IN
2 Polarity 1 Which line transition to respond to. One of: Rising Edge (1), Falling Edge (2) or Both (3)
3 Ignored for MTi 1-series
4 Skip First 2 The number of initial events to skip before taking
action.
6 Skip Factor 2 The number of events to skip after taking the
action before taking action again.
8 Ignored for MTi 1-series
10 Delay or Clock
2 Delay after receiving a sync pulse to taking action
(100μs units, range [0..60000])
www.xsens.com 21 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
7 Magnetic interference
Magnetic interference can be a major source of error for the heading accuracy of any Attitude and Heading Reference System (AHRS). As an AHRS uses the magnetic field to reference the dead-reckoned orientation on the horizontal plane with respect to the (magnetic) North, a severe and prolonged distortion in that magnetic field will cause the magnetic reference to be inaccurate. The MTi 1-series module has several ways to cope with these distortions to minimize the effect on the estimated orientation.
7.1 Magnetic Field Mapping
When the distortion is deterministic, i.e. when the distortion moves with the MTi, the MTi can be calibrated for this distortion this type of errors are usually referred to as soft and hard iron distortions. The Magnetic Field Mapping procedure compensates for both hard-iron and soft-iron distortions. In short, the magnetic field mapping (calibration) is performed by moving the MTi together with the object/platform that is causing the distortion. On an external computer (Windows or Linux), the results are processed and the updated magnetic field calibration values are written to the non-volatile memory of the MTi 1-series module. The magnetic field mapping procedure is extensively documented in the Magnetic Field Mapper User Manual (MT0202P), available in the MT Software Suite.
7.2 Active Heading Stabilization (AHS)
It is often not possible or desirable to connect the MTi 1-series module to a high-level processor/host system, so that the Magnetic Field Mapping procedure is not an option. Also, when the distortion is non- deterministic the Magnetic Field Mapping procedure does not yield the desired result. For all these situations, the on-board XKF3 sensor fusion algorithm has integrated an algorithm called Active Heading Stabilization (AHS). The AHS algorithm delivers excellent heading tracking accuracy. Heading tracking drift in the MTi 1-series can be as low as 1 deg per hour, while being fully immune to magnetic distortions. AHS is only available in the VRU_general filter profile. This filter profile is the only filter profile in the MTi-2 VRU and one of the 5 available filter profiles in the MTi-3 AHRS.
www.xsens.com 22 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
8 Package and handling
Note that this is a mechanical shock (g) sensitive device. Proper handling is required to prevent damage to the part. Note that this is an ESD-sensitive device. Proper handling is required to prevent damage to the part.
8.1 Package drawing
The MTi 1-series module is compatible with JEDEC PLCC28 IC-sockets. Figure 11: General tolerances are +/- 0.1 mm Figure 12: Recommended MTi 1-series module footprint
www.xsens.com 23 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
8.2 Packaging
The MTi 1-series module is shipped in trays. Trays are available with a MOQ of 20 modules. A full tray contains 152 modules. Figure 13: A tray containing 20 MTi 1-series modules
8.3 Reflow specification
The moisture sensitivity level of the MTi 1-series modules corresponds to JEDEC MSL Level 3, see also: IPC/JEDEC J-STD-020E “Joint Industry Standard: Moisture/Reflow Sensitivity Classification for non- hermetic Solid State Surface Mount Devices” IPC/JEDEC J-STD-033C “Joint Industry Standard: Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices”. The sensor fulfils the lead-free soldering requirements of the above-mentioned IPC/JEDEC standard, i.e. reflow soldering with a peak temperature up to 260°C. Recommended Preheat Area (ts) is 80-100 sec. The minimum height of the solder after reflow shall be at least 50µm. This is required for good mechanical decoupling between the MTi 1- series module and the printed circuit board (PCB) it is mounted on. Assembled PCB’s may NOT be cleaned with ultrasonic cleaning.
www.xsens.com 24 Document MT0512P.A © Xsens Technologies B.V. Data sheet MTi 1-series
9 Trademarks and revisions
9.1 Trademarks
© 2005-2015, Xsens Technologies B.V. All rights reserved. Information in this document is subject to change without notice. Xsens, MVN, MotionGrid, MTi, MTi-G, MTx, MTw, Awinda and KiC are registered trademarks or trademarks of Xsens Techno logies B.V. and/or its parent, subsidiaries and/or affiliates in The Netherlands, the USA and/or other countries. All other trademarks are the property of their respective owners.
9.2 Revisions
A 8 Jul 2015 MHA Initial release