SENSOR SOLUTIONS ///MSP340 Page 1 09/2015 Shown with Packard Connector Shown with Packard Connector MSP340 Pressure Transducer SPECIFICATIONS Low Cost OEM 100% Leak Proof No O-Rings No Silicon Oil No Welds The MSP340 pressure transducer from the Microfused™ line of MEAS is great for high volume, commercial and industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The transducer pressure cavity is machined from a solid piece of 17-4 PH stainless steel. The standard version includes a 1/4 NPT pipe thread allowing a leak-proof, all metal sealed system. There are no O-rings, welds or organics exposed to the pressure media. The durability is excellent. MEAS’ proprietary Microfused™ technology, derived from demanding aerospace applications, employs micromachined silicon piezoresistive strain gages fused with high temperature glass to a stainless steel diaphragm. This approach achieves media compatibility simply and elegantly while providing an exceptionally stable sensor without the p-n junctions of conventional micromachined sensors. This product is geared to the OEM customer who uses medium to high volumes. The standard version is suitable for many applications, but the dedicated design team at our Transducer Engineering Center stands ready to provide a semi-custom design where the volume and application warrants.
SENSOR SOLUTIONS ///MSP340 09/2015 Page 2
FEATURES
One-Piece Stainless Steel Construction Ranges up to 10kpsi or 700Bar mV or Amplified Outputs Ultra Compact Construction Hermetically Isolated Sensor Technology
APPLICATIONS
Pumps and Compressors Hydraulic/Pneumatic Systems After Market Automotive Tank Pressure in Breathing Apparatuses Agriculture – Sprayers and Dusters Refrigeration – Freon and Ammonia Based STANDARD RANGES Range psig Range Barg 0 to 50 0 to 3 0 to 100 0 to 7 0 to 300 0 to 20 0 to 500 0 to 35 0 to 1k 0 to 70 0 to 3k 0 to 200 0 to 5k 0 to 350 0 to 10k 0 to 700
SENSOR SOLUTIONS ///MSP340 09/2015 Page 3 PERFORMANCE SPECIFICATIONS Supply Voltage: 5.0V, Ambient Temperature: 25°C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Zero Offset Tolerance -2.0 2.0 %F.S. 1 Span Tolerance -2.0 2.0 %F.S. 1 Accuracy (combined non linearity, hysteresis, and repeatability) -1.0 1.0 %F.S. 2 Long Term Stability (1 year) -0.25 0.25 %F.S. Isolation, Body to Any Lead (@250Vdc) 50 MΩ Temperature Error – Zero -2.0 2.0 %F.S. Temperature Error – Span -2.0 2.0 %F.S. Compensated Temperature 0 55 °C Operating Temperature -20 +85 °C Storage Temperature -40 +85 °C Pressure Cycles (Zero to Full Scale) 10 Million Proof Pressure 2X Rated Burst Pressure 5X Rated Load Resistance (RL, mV Output) RL > 1 MΩ Load Resistance (RL, V Output) RL > 5 KΩ Bandwidth DC to 1KHz (typical) Shock 50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A Vibration ±20g, MIL-STD-810C, Procedure 514.2-2, Curve L For custom configurations, consult factory. Notes 1. Over compensated temperature range. 2. Best fit straight line.
SENSOR SOLUTIONS ///MSP340 09/2015 Page 4 DIMENSIONS
SENSOR SOLUTIONS ///MSP340 09/2015 Page 5 CODE CONNECTION
1 CABLE,4 WIRE
BELDEN#8444, 2 FEET DIM A 1.62[41.15]
2 CABLE,4 WIRE
BELDEN#8444, 4 FEET DIM A 1.62[41.15] DIM A 1.68[42.67] DIM B 2.43[61.72] PACKARD Metri-Pack CONNECTOR DIMENSIONS OUTPUT OPTIONS Supply(V) Code Output MIN TYP MAX 2 0 – 20mV/V (ratiometric) 2.5 5 12 3 0.5 – 4.5V (ratiometric) 4.75 5 5.25 4 1 – 5V 10 30 Packard connector not available with mV output. Wiring Code Code Output +Supply -Supply +Out -Out 2 0 – 20mV/V (ratiometric) Red Black Green White 3 0.5 – 4.5 V (ratiometric) Pin A Pin B [Common] Pin C N/A 4 1 – 5 V Pin A Pin B [Common] Pin C N/A
SENSOR SOLUTIONS ///MSP340 09/2015 Page 6
ORDERING INFORMATION
Pressure Port (See Pressure Port Table) Specials (nnnnn = Custom Drawing) Output (See Output Options Table) Electrical Connection (1 = 2ft Cable, 2 = 4ft Cable, 4 = Packard Metri-Pack) Type (G = Gage) Pressure Range (See Standard Ranges Table) Model Units (P = psi, B = Bar) TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believe d to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligation s shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2015 TE Connectivity Ltd. family of companies All Rights Reserved. NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company
45738 Northport Loop West
Fremont, CA 94538 Tel: 1-800-767-1888 Fax: 1-510-498-1578 Sales: pfg.cs.amer@meas-spec.com EUROPE Measurement Specialties (Europe), Ltd., a TE Connectivity Company
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00 Fax: +33 (0) 134 81 03 59 Sales: pfg.cs.emea@meas-spec.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518057 China Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 Sales: pfg.cs.asia@meas-spec.com