Features

  • 123pin Pmod compatible connector
  • I 2C interface
  • Secondary 123pin connector allows daisy chain
  • FPGA fabric available for download
  • µC C code available for download
  • Selectable resolution for pressure
  • Selectable resolution for humidity and temperature
  • Electronic ID code stored on chip

Digital Pressure and Humidity Sensor SENSOR SOLUTIONS /// MS8607 PERIPHERAL MODULE Page 2 Performance

  • Pressure range: 300 to 1200 mbar
  • 0% to 100% relative humidity range
  • 340°C to 125°C temperature range
  • Operates from 1.5V to 3.6V
  • Absolute Pressure accuracy ±2mBar (25°C)
  • Absolute Humidity accuracy ±3%RH (25°C, 20380%RH)
  • Absolute Temperature accuracy ±1°C (320Oelipsis+85°C) Schematic

Digital Pressure and Humidity Sensor SENSOR SOLUTIONS /// MS8607 PERIPHERAL MODULE Page 3 Connector Pin Assignments (1 2C Communications) System Plug (Table 1) Expansion Socket (Table 2) Dimensions(mm) Connector J1 Pin No. Signal Description

1 N/C Not Connected

2 N/C Not Connected

3 SCL I 2C Serial Clock

4 SDA I

5 GND Ground

6 Vdd Power Supply

7 N/C Not Connected

8 N/C Not Connected

9 SCL I 2C Serial Clock

10 SDA I

11 GND Ground

12 Vdd Power Supply

Pin No. Signal Description

9 N/C Not Connected

10 N/C Not Connected

11 N/C Not Connected

12 N/C Not Connected

Digital Pressure and Humidity Sensor SENSOR SOLUTIONS /// MS8607 PERIPHERAL MODULE Page 4 Detailed Description I C Interface The peripheral module can interface to the host in one of two ways. It can plug directly into a Pmod3compatible port (configured for I through connector J1, or in this case, other I 2C boards can attach to the same I 2C bus through connector J2. I 2C Interface (Daisy Chaining Modules) Alternatively, the peripheral module can connect to other I 2C3based Pmod modules through the expansion J2 connector. Connector J1 provides connection of the module to the Pmod host. The pin assignments and functions adhere to the Pmod standard as shown in Table 1. The J2 connector allows the module to be connected through a daisy3chain from another I 2C module and/or provide I 2C and power connections to other I 2C modules on the same bus. See Table 2. External Control Signals The IC operates as an I 2C slave using the standard 2 wire I 2C connection scheme. The IC is controlled either by the host (through the Pmod connector). In cases where one or more of the SCL and SDA signals are driven from an external source, resistors R1, R2 provide pull3up. However, this also increases the apparent load to the external driving source. If the external source is i ncapable of driving these loads, they should be removed. Reference Material

  • Refer to the MS8607 data sheet for detailed information regarding operation of the IC : http://www.meas3 spec.com/downloads/xxxxxxxxx.pdf
  • The complete software sensor evaluation kit for ZEDBOARD is available at http://www.meas3spec.com/TBD/xxxxx.zip (MS8607 ZedBoard Driver)
  • The complete software sensor evaluation kit for MICROZED BOARD is available at http://www.meas3spec.com/TBD/xxxxx.zip (MS8607 MicroZed Board Driver)
  • The Boot.bin file of MicroZed Touch Screen Demo Kit for Digital Component Sensors at http://www.meas3spec.com/TBD/xxxxx.zip (MicroZed Touch Screen Demo)

Ordering Information

MS8607 PERIPHERAL MODULE DPP901Z000 te.com/en/products/sensors.html TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2015 TE Connectivity Ltd. family of companies All Rights Reserved. 000000XX 03/15 Original PRODUCT SHEET Contact us: Measurement Specialties Inc – MEAS France Impasse Jeanne Benozzi CS 83 163