MS2000 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Features
- Pure Sine Wave – Power your TVs, computers, and other sensitive electronics without worry. The MS Series provides clean, reliable inverter power with low total harmonic distortion (THD) of less than 5%.
- Accessible Design – The extra large AC access cover with terminal screw block and 360° DC connection terminals with covers make this inverter accessible.
- Choices – The MS Series comes in 12, 24, and 48 volt configurations, allowing you to choose the model that is right for you.
- Versatile Mounting – Mount the MS Inverter/Charger on a shelf, bulkhead, or even upside down.
- Lightweight – The lightweight aluminum base and cover also provides noise reduction and corrosion resistance.
- Multiple Ports – The MS Series provides multiple ports, including an RS485 communication port for network expansion, and a remote port.
- Convenient Switches – The MS Series comes with an on/off inverter-mounted switch with an easy-to-read LED indicator.
- Expanded Transfer Relay – 60 Amp transfer service is available on all models except MS2000, which is 30 Amp only. Introduction The MS Series Inverter/Charger is a pure sine wave inverter designed specifically for the most demanding mobile, backup, and off-grid applications. The MS Series Inverter/Charger is powerful, easy-to-use, and best of all, cost effective. Power Factor Corrected (PFC) Charger: Our PFC charger is built into all of our inverter/chargers. It uses less energy from a generator than a standard charger – 25-30% less AC current than standard chargers. Easy-to-install: Install the MS Series in four easy steps: simply connect the inverter’s output to your distribution circuits or electrical panel, connect your utility power cable to the inverter’s easy-to-reach terminal block, connect the batteries, and switch on the power. Model Numbers
- MS2000
- MS2000-15B
- MS2000-20B
- MS2012
- MS2012-15B
- MS2012-20B
- MS2024
- MS2812
- MS4024 (series stackable)
- MS4048
- MS4048-20B Available For
- Backup Systems
- Marine Systems
- Off-Grid Systems
- RV Systems
- Trucks Available Accessories
- AGS
- Battery Monitor Kit
- Conduit Box
- DC Load Disconnect
- Remote Switch Adapter
- Fuse Blocks
- MagWeb
- Remote - ME-ARC
- Remote - ME-RC
- Smart Battery Combiner New features available using the ME-ARC (with v5.4 or higher firmware).
Copyright © 2019 Sensata Technologies, Inc. www.sensata.com SPECIFICATIONS MS2000/12 MS2012 (-15/-20B) MS2812 MS2024 MS4024 MS4048 MS4048-20B INVERTER SPECIFICATIONS AC output voltage accuracy 120 VAC ± 5% 120 VAC ± 5% 120 VAC ± 5% 120 VAC ± 5% 120 VAC ± 5% Total Harmonic Distortion (THD) < 5% < 5% < 5% < 5% < 5% 1 msec surge current (amps AC) 50 70 75 120 120 100 msec surge current (amps AC) 33 40 37 82 72 5 sec surge power (real watts) 3300 3900 2850 5800 8500 30 sec surge power (real watts) 3100 3800 2750 5400 5750 5 min surge power (real watts) 2800 3200 2700 4900 5250 30 min surge power (real watts) 2200 3000 2200 4500 4750 Maximum continuous input current 267 ADC 373 ADC 133 ADC 267 ADC 133 ADC Inverter efficiency (peak) 90.6% 90% 86% 93.7% 94% AC Relay Transfer time (minimum) 16 msecs 16 msecs 16 msecs 16 msecs 16 msecs Power Consumption - searching <8 watts <8 watts <8 watts <8 watts <8 watts Power Consumption - inverting (no load) 25 watts 30 watts 25 watts 25 watts 25 watts Output Waveform Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave CHARGER SPECIFICATIONS Continuous output at 25° C 100 ADC 125 ADC 60 ADC 105 ADC 60 ADC Charger efficiency 85% 85% 85% 85% 85% Input current for continuous rated output 15 AAC 18 AAC 7.9 A AC 29 AAC 30 AAC Pure Sine Wave 12, 24, 2000-
4000 W Battery Voltage Options Continuous Output Options
InverterInfo@sensata.com Power Conversion www.magnum-dimensions.com Page 3 Rev: 07/20/19 Part#64-0200 vK Copyright © 2019 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com GENERAL FEATURES AND CAPABILITIES Transfer relay capability 30 ACC max. each input (30AC total on MS2000 models, 60ACC total on all other models)* Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™ Battery temperature compensation Standard with available temp sensor connected (battery temp 0-50° C) Internal cooling 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans Overcurrent protection Yes, with two overlapping circuits Overtemperature protection Yes on transformer, MOSFETS, and battery Corrosion protection Yes, PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners Branch-rated output circuit breakers Optional on the MS2000 (15 or 20 amp breakers), MS2012 (15 or 20 amp breakers) or MS4048 (20amp breakers) Warranty Three years parts and labor PHYSICAL SPECIFICATIONS Mounting Shelf or wall (vents not allowed to face downward unless ME-CB or MMP/MP is installed Max operating altitude 15,000’ (4570 m) 15,000’ (4570 m) 15,000’ (4570 m) 15,000’ (4570 m) 15,000’ (4570 m) Temperature (Operating/Non-operating) -20° C to +60° C (-4° F to 140° F) to -40° C to +70° C (-40° F to 158° F) Operating humidity 0 to 95% RH non-condensing AGENCY APPROVALS & CERTIFICATIONS
- ETL Listed to UL/cUL 458, UL 1741, CSA C22.2 #107.1-01, meets KKK-A-1822E standard**
- The MS2000, MS2012, MS2812, MS4024 and MS4048 are ETL Listed to the stringent requirements of UL/cUL 458 for mobile use.
- The MS2012, MS2812, MS4024 and MS4048 are ETL Listed UL 1741 and CSA C22.2 #107.1-01 for renewable energy installations.
- All models also meet KKK-A-1822E standards for emergency vehicle use.** *The pass-thru capability on each leg of the -15B and -20B models is limited by the output breaker size on each output. **MS2000: ETL Listed to UL/cUL 458, CSA C22.2 #107.1-01, meets KKK-A-1822E standard Testing for specifications at 25° C. Specifications subject to change without notice. GENERAL NOTES