DC/DC CONVERTER 30W, Single & Dual Output E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/03/19 REV:7 Page 1 of 6

FEATURES

►2”x 1.6”x 0.4” Metal Package ►Ultra-wide 4:1 Input Range ►Operating Temp. Range –40°C to +80°C ►Short Circuit Protection ►I/O-isolation 1500 VDC ►Input Filter meets EN 55022,class A and FCC, level A ►3 Years Product Warranty PRODUCT OVERVIEW The MINMAX MPW2000 series is a range of isolated 30W DC/DC converter modules featuring fully regulated output voltages and ultra-wide 4:1 input voltage ranges.The product comes in a 2”x 1.6”x 0.4” metal package with industry standard pinout. An excellent efficiency allows an operating temperature range of –40° to +80°C (with derating). Typical applications for these converters are battery operated equipment and instrumentation, distributed power systems, data communication and general industrial electronics. Model Selection Guide Output Current Input Current Efficiency (typ.) Input Voltage (Range) Output Voltage Max. Min. @Max. Load @No Load Reflected Ripple Current Over Voltage Protection Max. capacitive Load @Max. Load Model Number VDC VDC mA mA mA(typ.) mA(typ.) mA (typ.) VDC μF % MPW2031 3.3 5500 400 922 3.9 10000 82 MPW2032 5 5000 350 1225 6.8 10000 85 MPW2033 12 2500 166 1404 15 1000 89 MPW2034 15 2000 133 1404 18 1000 89 MPW2036 ±12 ±1250 ±83 1404 ±15 330# 89 MPW2037 (10 ~ 40) ±15 ±1000 ±65 1404 20 50 ±18 330# 89 MPW2041 3.3 5500 400 461 3.9 10000 82 MPW2042 5 5000 350 613 6.8 10000 85 MPW2043 12 2500 166 702 15 1000 89 MPW2044 15 2000 133 702 18 1000 89 MPW2046 ±12 ±1250 ±83 702 ±15 330# 89 MPW2047 (18 ~ 75) ±15 ±1000 ±65 702 10 25 ±18 330# 89 # For each output Input Specifications Parameter Model Min. Typ. Max. Unit 24V Input Models -0.7 --- 50 Input Surge Voltage (1 sec. max.) 48V Input Models -0.7 --- 100 24V Input Models 9.4 9.7 10 Start-Up Threshold Voltage 48V Input Models 17 17.5 18 24V Input Models 9 9.3 9.5 Under Voltage Shutdown 48V Input Models 16 16.5 17 VDC Reverse Polarity Input Current --- --- 2 A Short Circuit Input Power --- --- 4500 mW Internal Power Dissipation --- --- 5500 mW Conducted EMI All Models Compliance to EN 55022,class A and FCC part 15,class A

DC/DC CONVERTER 30W, Single & Dual Output E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/03/19 REV:7 Page 2 of 6 Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy At 50% Load and Nominal Vin --- --- ±1.0 %Vom. Output Voltage Balance Dual Out put, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. --- ±0.2 ±0.5 % Load Regulation Io=50% to 100% --- ±0.3 ±1.0 % Ripple & Noise (20MHz) --- 55 80 mV P-P Transient Recovery Time --- 150 300 μsec Transient Response Deviation 25% Load Step Change --- ±2 ±4 % Temperature Coefficient --- ±0.01 ±0.02 %/ ℃ Over Temperature Protection Case Temper ature, automatic recovery 107 112 117 ℃ Over Load Protection 120 --- 180 % Output Short Circuit Continuous General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage Rated 60 Seconds 1500 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- M Ω I/O Isolation Capacitance 100KHz, 1V --- 1200 1500 pF Switching Frequency 290 330 360 KHz MTBF (calculated) MIL-HDBK-217F@25 ℃, Ground Benign 450,000 --- --- Hours Safety Approvals UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-scheme) Input Fuse 24V Input Models 48V Input Models 5000mA Slow-Blow Type 3000mA Slow-Blow Type Remote On/Off Control Parameter Conditions Min. Typ. Max. Unit Converter On 2.5V ~ 100V or Open Circuit Converter Off -1V ~ 1V or Short Circuit Control Input Current (on) Vctrl = 5.0V --- --- 5 μA Control Input Current (off) Vctrl = 0V --- --- -100 μA Control Common Referenced to Negative Input Standby Input Current Nominal Vin --- 2 5 mA Output Voltage Trim Parameter Conditions Min. Typ. Max. Unit Trim Up / Down Range % of nominal output voltage ±9.0 ±10.0 ±11.0 % Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +80 ℃ Case Temperature Range --- +105 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection RFI Six-Sided Shielded, Metal Case Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃

DC/DC CONVERTER 30W, Single & Dual Output E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/03/19 REV:7 Page 3 of 6 Power Derating Curve Output Power (%) Ambient Temperature 100 -40 0 20 60 100 1108040 400LFM 200LFM 100LFM Natural convection C Derating Curve without Heatsink Derating Curve with Heatsink Notes 1 Specifications typical at Ta=+25 ℃, resistive load, nominal input voltage, rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 Ripple & Noise measurement bandwidth is 0-20 MHz. 4 These power converters require a minimum out put loading to maintain specified regulation. 5 Operation under no-load c onditions will not damage these modules; however, they may not meet all specifications listed. 6 All DC/DC converters should be externally fused at the front end for protection. 7 Other input and output voltage may be av ailable, please contact factory. 8 To order the converter with heatsink, please add a suffix H. (e.g. MPW2031H). 9 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 10 Specifications subject to change without notice.

DC/DC CONVERTER 30W, Single & Dual Output E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/03/19 REV:7 Page 4 of 6 Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin

4 Remote On/Off Remote On/Off

5 No Pin +Vout

8 Trim Trim

►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pin pitch tolerance: ±0.25 (0.01) Physical Characteristics Case Material : Metal With Non-Conductive Baseplate Base Material : FR4 PCB (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Go ld Plate Over Nickel Underplate Weight : 48g Heat-sink Physical Characteristics Heatsink Material : Aluminum Finish : Anodic treatment (black) Weight : 15g ►The advantages of adding a heatsink are: 1. To help heat dissipation and increase the stability and reliability of DC/DC converters at high operating temperature atmosphere. 2. To upgrade the operating temperature of DC/DC converters, please refer to Derating Curve. 10.16 [0.40] 10.16 [0.40] 10.16 [0.40] [0.20] 5.08 45.72 [1.80] 50.8 [2.00] Bottom View 12 4 567 8 6.0 [0.24] 10.2 [0.40] 1.0 [ 0.04] 7.6 [0.40] 10.165.08 [0.20] 3.6 [0.14] [0.30] 1.1 [0.04] 40.6 [1.60] 23.0[0.91] 55.32[2.18]Max 17.2[0.68]Max Heat-sink Thermal pad Clamp Converter

DC/DC CONVERTER 30W, Single & Dual Output E-mail:sales@minmax.com.tw Tel:886-6-2923150 2012/03/19 REV:7 Page 5 of 6 Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a 1μF ceramic capacitor and a 10μF tantalum capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Technical Notes Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. 4) during a logic low is -100 μA. The maximum allowable leakage current of a switch connected to the on/off terminal (Pin 4) at logic hight (2.5V to 100V) is 5μA. Output Voltage Trim Output voltage trim allows the user to increase or decrease the output voltage set point of a module. The output voltage can b e adjusted by placing an external resistor (Radj) between the Trim and +Vout or -Vout terminals. By adjusting Radj, the output voltage can be change by ±10% of the nominal output voltage. A 10K, 1 or 10 Turn trimpot is usually specified for continuous trimming. Trim pin may be safely left floating if it is not used. Connecting the external resistor (Radj-up) between the Trim and -Vout pins increases the output voltage to set the point as defined in the following equation: () ( ) Vout-Vadj Vadj×30-Vout×33=up-Radj Connecting the external resistor (Radj-down) between the Trim and +Vout pins decreases the output voltage set point as defined in the following equation: ( ) () Vadj-Vout Vout×33-Vadj×667.36=down-Radj Vout: Nominal Output Voltage Vadj: Adjusted Output Voltage Units: VDC/KΩ Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Overvoltage Protection The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data. +Out -Out +V in -Vin Trim Up Enable Trim Trim Down 10K Trim Up/Down

DC/DC CONVERTER 30W, Single & Dual Output 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw 2012/03/19 REV:7 Page 6 of 6 Minmax Technology Co., Ltd. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 33μF for the 24V input devices and a 10μF for the 48V devices. +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7μF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Maximum Capacitive Load The MPW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from measurements obtained in a test setup. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in