MPW2000 TOTAL-POWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
89{18702{65{1000{15MPW2047 89{15702{83{1250{12MPW2046 8918702133200015MPW2044 8915702166250012MPW2043 856.861335050005MPW2042 823.9 2510 46140055003.3 ( 18 ~ 75 ) MPW2041 89{181404{65{1000{15MPW2037 89{151404{83{1250{12MPW2036 89181404133200015MPW2034 89151404166250012MPW2033 856.8122535050005MPW2032 823.9 5020 92240055003.3 ( 10 ~ 40 ) MPW2031 % (Typ.)VDCmA (Typ.)mA (Typ.)mA (Typ.)mAmAVDCVDC @Max. Load@No Load@Max. LoadMin.Max. EfficiencyOver Voltage Protection Reflected Ripple Current Input CurrentOutput CurrentOutput Voltage Input Voltage Model Number Model Selection Guide # For each output uF330330100010001000010000Maximum Capacitive Load Unit{15V #{12V #15V12V5V3.3VModels by Vout Capacitive Load 3000mA Slow - Blow Type5000mA Slow - Blow Type 48V Input Models24V Input Models Input Fuse Selection Guide Pi FilterInput Filter All Models Reverse Polarity Input Current 1716.51648V Input Models 9.59.3924V Input ModelsUnder Voltage Shutdown 1817.51748V Input Models VDC 109.79.424V Input ModelsStart Voltage UnitMax.Typ.Min.ModelParameter Input Specifications MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com
]117112107Case Temperature, automatic recoveryOver Temperature Protection KHz360330290Switching Frequency pF15001200---100KHz,1VIsolation Capacitance UnitMax.Typ.Min.ConditionsParameter General Specifications ContinuousOutput Short Circuit %/]{0.02{0.01---Temperature Coefficient %{4{2---Transient Response Deviation uS300150---25% Load Step ChangeTransient Recovery Time %180---120Over Power Protection mV P-P8055---Ripple & Noise (20MHz) %{1.0{0.3---Io=50% to 100%Load Regulation %{0.5{0.2---Vin=Min. to Max.Line Regulation %{2.0{0.5---Dual Output, Balanced LoadsOutput Voltage Balance %{1.0{0.5---Output Voltage Accuracy UnitMax.Typ.Min.ConditionsParameter Output Specifications Referenced to Negative InputControl Common mA52---Device Standby Input Current VDC1----1Supply Off VDC2.5 to 100VDC or Open CircuitSupply On UnitMax.Typ.Min.ConditionsParameter Remote On/Off Control %{11.0{10.0{9.0% of nominal output voltageTrim Up / Down Range UnitMax.Typ.Min.ConditionsParameter Output Voltage Trim Notes1: 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com
+Vo PWM Isolation Ref.Amp LC Filter+Vin -Vin Com. -Vo On/Off Trim OVP OTP OVP Single Output +Vo PWM Isolation Ref.Amp LC Filter+Vin -Vin -Vo On/Off Trim OVP OTP OVP Vin ( VDC ) 10uS 150 140 130 120 110 100 100uS 1mS 10mS 100mS 48VDC Input Models 24VDC Input Models Input Voltage Transient Rating MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com
Derating Curve with HeatsinkDerating Curve without Heatsink ]Ambient Temperature Output Power (%) 100 -40 50 60 80 100 110 9070 400LFM 200LFM 100LFM Natural convection ]Ambient Temperature Output Power (%) 100 -40 50 60 80 100 110 9070 400LFM 200LFM100LFM Natural convection Efficiency vs Output Load ( Dual Output )Efficiency vs Output Load ( Single Output ) 100 Load Current(%) 10 20 6040 80 100 Efficiency (%) Load Current(%) 10 20 60 40 80 100 100 Efficiency (%) Efficiency vs Input Voltage ( Dual Output )Efficiency vs Input Voltage ( Single Output ) 100 NomLow High Input Voltage (V) Efficiency (%) NomLow High Input Voltage (V) 100Efficiency (%) MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com
Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. Peak-to-Peak Output Noise Measurement Test Use a Cout 1.0uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. Design & Feature Considerations Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -1V to 1.0V. A logic high is 2.5V to 100V. The maximum sink current at the on/off terminal (Pin 4) during a logic low is -100 uA. The maximum allowable leakage current of a switch connected to the on/off terminal (Pin 4) at logic hight (2.5V to 100V) is 5uA. Output Voltage Trim Output voltage trim allows the user to increase or decrease the output voltage set point of a module. The output voltage can be adjusted by placing an external resistor (Radj) between the Trim and +Vout or -Vout terminals. By adjusting Radj, the output voltage can be change by {10% of the nominal output voltage. A 10K, 1 or 10 Turn trimpot is usually specified for continuous trimming. Trim pin may be safely left floating if it is not used. Connecting the external resistor (Radj-up) between the Trim and -Vout pins increases the output voltage to set the point as defined in the following equation: Vadj - Vout (33*Vout)- (30*Vadj)Radj-up = Connecting the external resistor (Radj-down) between the Trim and +Vout pins decreases the output voltage set point as defined in the following equation: Vout-Vadj (36.667*Vadj) - (33*Vout)Radj-down = VDC/ K[:Units Adjusted Output Voltage:Vadj Nominal Output Voltage:Vout Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Overvoltage Protection The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data. MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Trim Up Enable Trim Trim Down 10K Trim Up/Down
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 33uF for the 24V input devices and a 10uF for the 48V devices. Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7uF capacitors at the output. Maximum Capacitive Load The MPW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 330uF maximum capacitive load for dual outputs, 1000uF capacitive load for 12V & 15V outputs and 10000uF capacitive load for 3.3V & 5V outputs. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105°C. The derating curves are determined from measurements obtained in an experimental apparatus. MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in
2.To upgrade the operating temperature of DC/DC converters, please refer to Derating Curve. 1.To help heat dissipation and increase the stability and reliability of DC/DC converters at high operating temperature atmosphere. The advantages of adding a heatsink are: 2g:Weight Anodic treatment (black):Finish Aluminum:Heat-sink Material 23.0[0.91] 55.32[2.18] max. 16.3[0.64] max. Heat-Sink Thermal pad Clamp Converter UL94V-0:Flammability 48g:Weight Metal With Non-Conductive Baseplate:Case Material 2.0*1.6*0.37 inches 50.8*40.6*9.3 mm :Case Size Physical CharacteristicsMechanical Dimensions TrimTrim8 -Vout-Vout7 Common+Vout6 +VoutNo Pin5 Remote On/OffRemote On/Off4 -Vin-Vin2 +Vin+Vin1 Dual OutputSingle OutputPin Pin Connections 1. To order the converter with Heatsink, please add a suffix H (e.g. MPW2031H). Notes2: {0.002{0.05Pin diameter X.XXX{0.01X.XX{0.25 X.XX{0.02X.X{0.5 InchesMillimetersTolerance MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com