MPU60A MPSIND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Electrical Characteristics: Sym. Parameter Test Conditions Min. Typ. Max. Unit Iil 1.62 Irh Eff REG-i REG-o OVP OCP Ttr Thold 16 Ts 0.3 0.3 0.4 Vrn Ilk Iih 0.72 Irl Pno TC -0.04 0.5 0.04 Vin=90 to 264VAC Io=Full load, Vin=115 VAC Io=Full Load, Vin=230VAC Io=Full Load Vin=230VAC Io=Full Load to Half Load, Vin=100VAC Io=Full Vin=110VAC Load, Vin=100VAC Full Load, Vin=100VAC Io= Full Load, Vin=240VAC Io=Full load, Vin= 230 VAC W V A A A A A No load,Vin=240VAC All output W % / C Input Voltage Input Frequency Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Transient Time of Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Input Current (High Line) No-Load Power Consumption Temperature Coefficient load, 25 , Coolstart,C Vin=115VAC Vin=230VAC mS S mA mS 264 90 See rating chart 26 30 43 47 Low Line Inrush Current VAC Hz Vin fin Po Vo Io load, 25 , Coolstart,C MPU60A SERIES 63W Desk Top Switching Power Supplies For Medical Equipment Io=Full Load, 92 87 132 150 110 112 High Line Inrush Current Io=Full Io=Full See rating chart 0.1 Environmental : Hr Relative Humidity 5 0.1M 95 % Toper Operating Temperature Tstg Storage Temperature MTBF 0 70 50 Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 85 -40 C C Sym. Parameter Test Conditions Min. Typ. Max. Unit Pd Derate linearly from 100% load at 50 C to 50% load at 70 C Features: Description: Wide Input Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single Output Output Voltage Available From 12VDC Thru 36VDC Optional Output Connector (See appendix) Input Surge Current, Over Voltage And Over Load protection Output Voltage Protection(Crowbar Desing) CEC level V and Engergy Star 2.0 Compliance Class I 3 year warranty Operating Voltage The MPU60A series of AC/DC switching mode power supplies provide 63 Watts of continuous output power . All supplies are UL94V-1 min compliant, include IEC-320-C14 input for worldwide applications. They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1) ,TUV/T-mark (EN 60601-1), and new CE requirements. All units are 100% burned in and tested. Hrs Note: The specifics for testing the energy efficiency of MPU60 Series are outlined in a separate document titled "Test Method for Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac PowerSupplies (August 11, 2004)," which is available on the ENERGY STAR Website. Safety Approvals : EN 60601-1EN 60601-1 IEC 60601-1IEC 60601-1 - 17 -

Note: 1. Dimensions are shown in inches or mm. 2. Weight: 330-380gs approx. 3. Optional output connector: See page Appendix. Mechanical Specifications: MPU60A SERIES Model Number Output Voltage Output Current Total Regulation Maximum MPU60A-105 5% 63W MPU60A-106 5% 63W MPU60A-107 5% 63W MPU60A-108 3% 63W MPU60A-109 3% 63W MPU60A-110 3% 63W

12 VDC

15 VDC

18 VDC

24 VDC

30 VDC

36 VDC

5.25 A 4.20 A 3.50 A 2.62 A 2.10 A 1.75 A Output Voltage And Current Rating Chart (Single Output) : Output Power Safety Specifications: Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 5656 VDC Primary to ground 2800 Test Voltage = 2100VDC 50 M Vin=220VAC B CLASS Sym. Vps Vpg Ris CISPR FCC Isolation Resistance EMI requirements for CISPR-11 for FCC PART-18 Vin=110VAC VDC B CLASS Dielectric Withstanding Voltage for Primary to Ground EMI requirements 63W Desk Top Switching Power Supplies For Medical Equipment The total regulation on model 105~107 is required to use AWG#16/2C/4FT output cable. The total regulation on model 108~110 is required to use AWG#18/2C/6FT output cable. The regulation and efficiency will be changed by modified output cable. Mark " " means " PSE approval "* - 18 -