MPU200-1012G BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 866 513 2839 © 2015 Bel Power Solutions, Inc. BCD.00604_AA The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry. The Bel Power Solutions dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch. RoHS Compliant Power Factor Correction (PFC) Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad model outputs V1 and V2 Remote sense on quad model outputs V1 and V2 Current share and N+1 redundancy (standard on all models) Overtemperature, overload, and overvoltage protection Available with SAE mountings MDU200 models have 48 VDC input
tech.support@psbel.com 200W/225 W PK with 300 LFM Forced-Air Cooling 1 MODEL7 OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT 2 PEAK OUTPUT CURRENT 2 LINE REGULATION LOAD REGULATION RIPPLE & NOISE % pk-pk 3 INITIAL SETTING ACCURACY
200 W with 300 LFM Forced-Air Cooling 1 - Isolated V3 and V4 can be used as positive or negative outputs
RIPPLE & NOISE % pk-pk 3 INITIAL SETTING ACCURACY MPU200-4530G
200 W with 300 LFM Forced-Air Cooling 1
RIPPLE & NOISE % pk-pk 3 INITIAL SETTING ACCURACY Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed. NOTES: 1 This product is not rated for convection applications. 2 The MPU/MDU200 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be applied from the input side of the power supply blowing towards the output. 3 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4 Total current for V1 and V2 is not to exceed 35A. 5 Total power on V3 and V4 is not to exceed 100W. 6 Derating is required on output voltages above 27VDC. Consult factory. 7 Non-G models use lead solder exemption and are not recommended for new designs. OPTIONS SUFFIXES TO ADD TO PART NUMBER Metric Mounting Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts. Consult factory for availability. Isolation Diode Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for availability. RoHS lead solder exempt No RoHS suffix character required. RoHS compliant for all 6 substances Add “G” as the last character of the part number.
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 200 watts 15 ms Input Current 85 VAC at full rated load. 4.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. Switching frequency of secondary transformer. Switching frequency of Power Factor Correction circuit. 100 120 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 200 watts, over DC input range. 15 ms Input Current 36 VDC at full rated load. 8.35 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Consult factory. Operating Frequency Switching frequency of main output transformer. Switching frequency of secondary transformer. 100 70 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full Rated Load, 110 VAC (MPU) or 48 VDC (MDU). Varies with distribution of loads among outputs. 65 75 % Minimum Load, V1 Minimum load required to maintain regulation on, V2 at maximum load. Minimum load required on single output models. Quad output model V1 Single output models V1 A Minimum Load, V3 Minimum load required to maintain regulation on V4 at maximum load. Quad output model V3 0.3 A Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 5 % Regulation Varies by output. Total regulation includes: line changes over the specified. Input range changes in load starting at 20% load and changing to 100% load. See Model Selection Charts Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 5% max. deviation. 500 μs Turn-on Delay Time required for initial output voltage stabilization. 2 s Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. MPU200 MDU200 50 80 ms
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. MPU200-4530G 3.3 V output MPU200-4530G 5 V output MPU200-4530G 12 V output MDU200/MPU200-1012G V1 MDU200/MPU200-1024G V1 MDU200/MPU200-1048G V1 3.8 6.0 17.0 32.0 58.0 4.2 6.4 20.5 38.0 62.7 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good Signal (Transition from Low to High) TTL compatible signal available for V1. Internal pull-up resistor is 475 Ω. Signal is high when output is above the specified limits. Signal shall remain low for 20 ms following loss of Output Good. 3.3 V 5 V 3.16 4.75 3.25 4.95 V MDU200/MPU200-1012G 12 V MDU200/MPU200-1024G 24 V MDU200/MPU200-1048G 48 V 10.5 21.5 43.0 11.9 23.5 47.0 V Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. 5 ms Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share on V1 and V2 with return via Sense return. 10 % Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with respect to the main output. 500 mV Inhibit Output voltage is inhibited by application of an external high (5 V) signal. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Safety Approvals Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 Dielectric Withstand Voltage Input to output per EN60950. MPU200 MDU200 2600
1414 VDC
Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. B B Class ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Transient Protection Per EN61000-4-5, class 3. MPU200: Line to Line MPU200: Line to Ground MDU200: Line to Line MDU200: Line to Ground 0.5 0.5 kV Insulation Resistance Input to Output. 10 MV Leakage Current Per EN60950. MPU200 Quad Output Model MPU200 Single Output Models MDU200 at 72 VDC (Not required by EN60950) 2.2 1.7 N/A mA
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating. Non-Operating. 10k 40k ASL Ft. Operating Temperature At 100% load Derate linearly above 50°C by 2.5% per °C. At 50% load 0 50 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 GRMS PARAMETER CONDITIONS / DESCRIPTION Metric Mounting Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts. Consult factory for availability. Isolation Diode Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for availability. PARAMETER DESCRIPTION Weight: 2 lb (0.89 kg)
Figure 1. Mechanical Drawing – Single Output
Figure 2. Mechanical Drawing – Quad Output equipment used in hazardous environments, or nuclear control systems. the date manufactured. Specifications are subject to change without notice.