Technical content
The innovative MPU150 incorporates Power Factor Correction (PFC) with a low profile package designed to meet 1U height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform to support mixed mode, high speed digital circuitry. Power-One’s unique dual converter architecture combines high reliability with exceptional regulation. All models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch. The MDU150 series provides the same benefits as the MPU150 series, with nominal 48 volt DC input.
FEATURES
- Power Factor Correction (PFC) Meets EN61000-3-2
- Low Profile Height Fits 1U Constraints
- Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications
- Single Wire Current Sense on Outputs V1 and V2
- Remote Sense on Outputs V1 and V2
- Overtemperature, Overload, and Overvoltage Protection
- Available with Metric or SAE Mountings
- Greater than 340,000 Hours MTBF
- MDU150 Models have 48VDC Input AC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY DC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING Advanced Product Release ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3) Total current between V1 and V2 is 30A, maximum rating. 4) Total current between V3 and V4 is 5A, maximum rating. Rev. 06/99
MPU150 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 150 watts. MPU150-4350 17.5 mS All other models 20 Input Current 85 VAC at full rated load. 3.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25° C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. 100 120 Switching frequency of secondary transformer. 65 90 kHz Switching frequency of Power Factor Correction circuit. 60 MDU150 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 150 watts, over DC input range. 20 mS Input Current 36 VDC at full rated load. 6.4 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Vin = 72 VDC. 35 APK Operating Frequency Switching frequency of main output transformer. 100 kHz Switching frequency of secondary transformer. 70 OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 65 75 % Minimum Loads Minimum load required to maintain regulation on MPU150-3300, V1 4 AV2 at maximum load. All other models, V1 3 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Charts Output Power With 300 LFM forced air cooling. (NOTE 1) 150 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified. See Model Selection Chartsinput range, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 500 µS5% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise fr om 10% to 90%. 20 mS NOTES: 1) This product is not rated for convection applications. INTERFACE SIGNALS AND INTERNAL PROTECTION MPU/MDU150 SERIES
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. Available on 3.3V output, V1 4.1 4.65 V1, V2, all models, and V3 on all models except 3.3V output, V2 3.8 4.2 MPU150-3300. 5V output, V1, V2 6.0 6.4 V 12V output, V2 (Note 1) 14 16 MPU150-4350. 3.3V output, V1 4.3 4.65 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good TTL compatible signal available for V1. Signal is high when 3.3V 3.16 output is within 5% of nominal. Signal shall r emain low for 20 5V 4.75 V milliseconds following loss of Output Good. Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input 5 mSpower. May be used as independent PSOK signal in r edundant applications. Current Share Accuracy of shared current with up to 6 parallel units. Single wir e current share 10 % on V1 and V2 with return via -Sense return. Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with 250 mVrespect to the main output. Inhibit Output voltage is inhibited by application of an exter nal high (5V) signal. NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 NO. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to output per EN60950. MPU150 2600 VDCMDU150 1544 Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part J - Conducted. B ClassEN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Transient Protection Per EN61000-4-5, class 3. Line to Line 1 kVLine to Ground 2 Insulation Resistance Input to output. 10 MΩ Leakage Current Per EN60950. MPU150 at 264 VAC 1250 µAMDU150 at 72 VDC 100 ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature At 100% load 0 50 ° C Derate linearly above 50° C by 2.5% per ° C. At 50% load 0 70 ° C Storage Temperature -55 85 ° C Temperature Coefficient 0° C to 70° C (after 15 minute warm-up). ±0.02 ±0.05 %/° C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 GRMS OPTIONS DESCRIPTION NOTES SIZE IMPACT Metric Mounting Add “M” as a suffix to the model number to or der chassis with 8.00" x 4.20" x 1.50"
J300 INTERFACE CONNECTIONS PIN 10. +S, V1 9. –S, V1 & –S, V2 8. CURRENT SHARE, V1 7. +S, V2 6. CURRENT SHARE, V2 5. NO CONNECTION 4. OUTPUT GOOD, V1 3. POWER FAIL WARNING 2. INHIBIT 1. SIGNAL GROUND RTN J3 +V3 RTN +V1 +V2 + or L - or N V1,V. ADJ. V2,V. ADJ. INPUT OUTPUTS: 8-32 SCREW CONNECTIONS,
4 PLACES
V3 ADJ. V1 & V2 RTN +V1 +V2 +V3 –V3 +V4 –V4 V1 ADJ. V2 ADJ. V4 ADJ. OUTPUTS: TRIPLE OUTPUT QUAD OUTPUT MPU/MDU150 SERIES 0.75" (19.1mm) 1.50" (38.1mm) 3.750" (95.3mm) 4.20" (106.7mm) 0.23" ±0.03" 8.00" (203.2mm) 7.400" (188.0mm) 0.75" (19.1mm) 0.30" (7.6mm) SUGGESTED AIR FLO W 6-32 FLUSH NUT 8 PLACES (BOTH SIDES TYP.) WITH METRIC MOUNTING OPTION: M4 X 0.7, 8 PLACES. MAXIMUM TORQUE: 3.5 IN/LBS (0.40N/M) CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH CONNECTOR MOLEX HOUSING PIN PINS PINS WIRE SERIES SERIES (LOOSE) (CHAIN) GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWGJ1 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG(ALL MODELS) 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG J2 5051-N 22-01-1022 2759 08-50-0114 08-50-0113 22-30AWG (TRIPLE OUTPUT) 5051-N 22-01-1022 2759 08-65-0805 08-65-0804 22-30AWG 41695 09-50-8021 6838 08-50-0189 08-50-0187 18-20AWGJ3 41695 09-50-8021 2478 08-50-0106 08-50-0105 18-20AWG(TRIPLE OUTPUT) 2139 09-50-3021 2478 08-50-0106 08-50-0105 18-20AWG 41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20AWGJ3 41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20AWG(QUAD OUTPUT) 2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20AWG J300 5264-N 50-37-5103 5263 80-70-1040 80-70-1039 22-28AWG