Electrical Characteristics: MPU12A SERIES 12W Wall Mount Switching Power Supplies For Medical Equipment Description: Features: Safety Approvals: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz

2 Prong Plug-In Mains Connector

Optional Output Connector (See appendix) Single Output Class II Over Voltage and Over Load protection. Over temperature Detection Energy Star 2.0, Efficiency level V 3 year warranty The MPU12A series of AC/DC switching mode power supplies provide 12 watts of continuous output power. This series is suitable for use in Blood Pressure measurements, Frequency Therapy Device and Dental Curing light applications.All models are designed ndto comply with UL/c-UL(UL60601-1:2 Edition), and new CE requirements. As long as faulty conditions have been removed , the adaptor will automatically power up as usual.○1 S E P Environmental : Toper Operating Temperature Tstg Storage Temperature 0 70 -40 Sym. Parameter Min. Typ. Max. UnitTest Conditions C C Hr Ho Storage Humidity 95 % %Operating Humidity Pd 95 0 Derate linearly from 100% load at 50 C to 50% load at 70 C Hrs MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M Sym. Vin fin Po Vo Io Iil Iih Irl Irh Eff REG-i REG-o OVP OCP Ttr Thold Ts Vp-p Ilk TC Pno Tjsd Safety Approvals Input Voltage Range Operate Voltage Range Input Frequency Output Power Range Vin=90 to 264VAC VAC VAC V A A A A mS mS mA %/°C S A Hz W W See rating chart See rating chart Output Voltage Range Output Current Range Input Current (Low Line) Io=Full load, Vin=115VAC Io=Full Load, Vin=230VAC Io=Full Load Vin=230VAC Io=Full Load, Vin=110VAC Io=Full Load, Vin=100VAC Full Load, Vin=90VAC Io=Full Load, Vin=230VAC All output No load, Vin=230VAC The parameter is not subject to production test-verified by design/characterization of integrated controller. Io=Full load, Vin=230VAC Io=Full load, 25°c, Cool start, Vin=115VAC Io=Full load, 25°c, Cool start, Vin=230VAC Input Current (High Line) Low Line Inrush Current High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Time of Transient Response Io=Full Load to Half Load, Vin=100VAC Hold-Up Time Start Up Time Temperature Coefficient No-Load Power Consumption Thermal Shutdown by Junction Temperature ControllerNo-Load Power Consumption Ripple & Noise(Peak to Peak) Safety Ground Leakage Current Parameter Test Conditions Min. Typ. Max. Unit 100 0.25 0.17 0.35 0.22 73.3 -0.04 -25 0.04 112 110 0.3 12 16 132 130 150 77.7 0.5 0.1 0.3 0.5 100 240 264

12W Wall Mount Switching Power Supplies For Medical Equipment Safety Specifications: Output Voltage And Current Rating Chart ( Single Output ) : Mechanical Specifications:( USA Type) Note: 1. Dimensions are shown in mm. 2. Weight: 130gs approx. 3. Optional output connector: See page Appendix. Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 5656 VDC Sym. Vps Vin=120VAC, 60Hz B CLASSCISPR FCC Meet EMI requirements: CISPR-11 Vin=120VAC, 60Hz B CLASSMeet EMI requirements: CRF 47, Part18 POWERPOWER Model Number Output Voltage Output Current Total ① Regulation Maximum Output Power MPU12A-102 5 ~ 6 VDC 2.00 ~ 1.66 A 5% 10W MPU12A-103 6 ~ 8 VDC 2.00 ~ 1.50 A 5% 12W MPU12A-104 8 ~ 11 VDC 1.50 ~ 1.09 A 5% 12W MPU12A-105 11 ~ 13 VDC 1.09 ~ 0.92 A 5% 12W MPU12A-106 13 ~ 16 VDC 0.92 ~ 0.75 A 5% 12W MPU12A-107 16 ~ 21 VDC 0.75 ~ 0.57 A 3% 12W MPU12A-108 21 ~ 27 VDC 0.57 ~ 0.44 A 3% 12W