MPOF120-20B15 MULTICOMP | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Features
- Universal 85V AC to 264V AC or 120V DC to 370V DC input voltage
- High power density, compact size: 3” × 2” × 1.22”
- Operating ambient temperature range: -40°C to +85°C
- Active PFC
- High I/O isolation test voltage up to 4000V AC
- Operating altitude up to 5000m
- Extremely low leakage current˂0.1mA
- Stand-by power consumption˂0.3W
- The base plate with conformal coating
- Output short circuit, over-current, over-voltage, over-temperature protection
- Efficiency up to 95%
- Installing in system of Safety Class I/II is available
- Safety according to IEC/EN/UL62368-1, IEC/EN60335-1,
- IEC/EN61558-1, GB4943-1, IEC/EN/ES60601-1 These series is one of AC-DC miniaturize open frame power supply. It features universal AC input and at the same time accepts DC input voltage, cost-effective, high efficiency, high reliability and double or reinforced insulation. These converters offer excellent EMC and safety performance, which meet IEC/EN/UL62368, GB4943, IEC/EN60335, IEC/EN61558, IEC/EN/ ES60601 standards and they are widely used in areas of industrial, LED, street light control, electricity, security, telecommunications, smart home, medical, etc. Selection Guide Part Number Nominal Output Power (W) Nominal Output Voltage and Current (Vo/Io) Transient Output Power*10S (W) Output Voltage Adjustable Range (V) Efficiency at 230VAC (%) Typ. Max. Capacitive Load (μF) MPOF120-20B12 114 12V/9.5A 141.6 11.4-12.6 94 6000 MPOF120-20B15 114 15V/7.6A 142.5 14.3-15.8 94 5000 MPOF120-20B24 120 24V/5A 150 22.8-25.2 95 3200 MPOF120-20B48 120 48V/2.5A 150 45.6-50.4 94.5 1600 Note: *If the total output power exceeds the nominal output power, it can be maintained for a maximum of 10s. The power supply cannot exceed the transient power. When the output voltage is increased, the total output power cannot exceed the nominal output power. Input Specifications Item Operating Conditions Min. Typ. Max. Unit Input Voltage Range AC input 85 -- 264 VAC DC input 120 -- 370 VDC Input Voltage Frequency 47 -- 63 Hz Input Current 115VAC -- -- 2 A 230VAC -- -- 1 Inrush Current 115VAC Cold start -- 40 -- 230VAC -- 75 -- Power Factor 115VAC Full Load 0.98 -- -- 230VAC 0.94 -- -- Leakage Current 240VAC ˂0.1mA; Single fault˂0.5mA Hot Plug Unavailable
Page <2> V1.026/02/21 120W AC to DC Open Frame Power Supply Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Output Specifications Item Operating Conditions Min. Typ. Max. Unit Output Voltage Accuracy* Full load range 12V/15V -- ±2.0 -- Line Regulation Rated load -- ±0.5 -- Load Regulation 0% - 100% load -- ±1.0 -- Ripple & Noise* 20MHz bandwidth (peak-to-peak value) 12V/15V -- 80 120 mV24V/27V -- 100 150 48V -- 120 200 Temperature Coefficient -- ±0.03 -- %/°C Minimum Load 0 -- -- % Hold-up Time 230VAC 15 -- -- ms Stand-by Power Consumption -- -- 0.3 W Short Circuit Protection Recovery time < 3s after the short circuit disappear. Hiccup, continuous, self-recovery Over-current Protection ≥130% Io, hiccup, self-recovery Over-voltage Protection 12V ≤16V (Output voltage turn off, re-power on for recover) 15V ≤25V (Output voltage turn off, re-power on for recover) 24V ≤32V (Output voltage turn off, re-power on for recover) 27V ≤35V (Output voltage turn off, re-power on for recover) 48V ≤60V (Output voltage turn off, re-power on for recover) Over-temperature Protection Output voltage turn off, re-power on to recovery after abnormal removed Note: 1. *Output voltage accuracy: including the setting error, line regulation, load regulation; 2. *The “Tip and barrel method” is used for ripple and noise test, output parallel 10uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to AC-DC Converter Application Notes for specific information; 3. *For all the above test items, please refer to our company standard “AC-DC Black Box Test Specification” for specific test specifications and methods; 4. *Except for special instructions, the above data are measured at the full operating temperature range and humidity <75%.
Page <3> V1.026/02/21 120W AC to DC Open Frame Power Supply Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro General Specifications Item Operating Conditions Min. Typ. Max. Unit Isolation Test Input - Electric strength test for 1min., leakage current <5mA 1500 VACInput - output 4000 -- Output - 500 -- Insulation Resistance Input - Ambient temperature: 25 ± 5°C Relative humidity: < 95%RH, no condensation Test voltage: 500V DC 100 -- MΩInput - output 100 -- Output - 100 -- Operating Temperature -40 +85 Storage Temperature -40 +85 Operating Humidity Non-condensing 10 95 %RH Storage Humidity 20 90 Switching Frequency Nominal output power 70 110 kHz Power Derating Operating temperature derating %/°C Input voltage derating 85VAC - 115VAC 1 -- %/VAC Safety Standard Meet IEC/EN/UL62368-1/EN60335-1/IEC/ EN61558-1 /GB4943-1/IEC/EN60601-1/ ES60601-1(3.1 version)/CAN/CSA- C22.2 No.60601-1:14-Edition 3/ EN60601-1-2 Edition 4 Safety Certification IEC/EN/UL62368-1/EN60335/ IEC61558(Pending) Safety Class CLASS I Isolation level Input - output 2 × MOPP Input - 1 × MOPP Output - 1 × MOPP MTBF MIL-HDBK-217F@25°C >300,000 h Warranty Ambient temperature: <50°C 5 years Mechanical Specifications Case Material Open frame Dimensions 76.2mm x 50.8mm x 31mm Weight 125g (Typ.) Cooling Method Free air convection Note: *Cooling method and power derating refer to typical characteristic curves.
Page <4> V1.026/02/21 120W AC to DC Open Frame Power Supply Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Electromagnetic Compatibility (EMC) Product Characteristic Curve Emissions CE CISPR32/EN55032 CLASS B RE CISPR32/EN55032 (Category I, CLASS B, category II, CLASS A) Harmonic current IEC/EN61000-3-2 CLASS A Immunity ESD IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV Perf. Criteria A RS IEC/EN 61000-4-3 10V/m Perf. Criteria A EFT IEC/EN 61000-4-4 ±2KV Perf. Criteria A Surge IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV Perf. Criteria A CS IEC/EN61000-4-6 10 Vr.m.s Perf. Criteria A Voltage dips, short interruptions and voltage variations immunity IEC/EN61000-4-11 0%, 70% perf. Criteria B Note: *The power supply should be considered as a part of the components in the system. All EMC performance are been tested on a metal plate with a thickness of 1mm and a length of 360mm × 360mm. The power supply must be combined with the terminal equipment for electromagnetic compatibility confirmation. MPOF120-20B24 MPOF120-20B48 MPOF120-20B12 MPOF120-20B24 MPOF120-20B48 MPOF120-20B12
Page <5> V1.026/02/21 120W AC to DC Open Frame Power Supply Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019. Notes: 1. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25°C, humidity<75%RH with nominal input voltage and rated output load; 3. All index testing methods in this datasheet are based on our company corporate standards; 4. In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product performance and reliability; 5. We can provide product customization service, please contact our technicians directly for specific information; 6. Products are related to laws and regulations: see “Features” and “EMC”; 7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units. Dimensions and Recommended Layout