‧No load power consumption<0.075W ‧Extremely low leakage current ‧EMI class B for class configuration Ⅱ File Name:MPM-05-SPEC 2017-08-08 M PM -05 seri es5W High Reliable Green Medical Encapsulated Type
OPERATING ALTITUDE Note.8 5000 meters MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE Note.2 RATED POWER OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.6 FREQUENCY RANGE EFFICIENCY (Typ.)INPUT INRUSH CURRENT (Typ.) WITHSTAND VOLTAGE ISOLATION RESISTANCE WORKING HUMIDITY WORKING TEMP. OVER TEMPERATURE STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE AC CURRENT (Typ.) 1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load 40ms/230VAC 12ms/115VAC at full load 80 ~ 264VAC 47 ~ 440Hz 0.2A/115VAC 0.1A/230VAC COLD START 25A/115VAC 45A/230VAC 110% ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 20 ~ 90% RH non-condensing -40 ~ +85℃ (Refer to "Derating Curve") ±0.03%/℃ (0 ~ 60℃) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes 1799.5Khrs min. MIL-HDBK-217F (25℃) SAFETY STANDARDS RIPPLE & NOISE (max.) Note.4 VOLTAGE TOLERANCE Note.5 ENVIRONMENT SAFETY & EMC (Note 9) PROTECTION Protection type : Shut off o/p voltage, clamping by zener diode Protection type : Shut down o/p voltage, recovers automatically after temperature goes down I/P-O/P:4KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH rd IEC60601-1, EN60601-1, UL ANSI/AAMI ES60601-1(3.1 version), CAN/CSA-C22 3 Edition approved ; Design refer to EN60335-1 LEAKAGE CURRENT (max.) Note.7 Touch current <80 A/264VACμ ISOLATION LEVEL Primary-Secondary: 2xMOPP Parameter Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions Conducted Radiated Harmonic Current Voltage Flicker Standard Standard EN55011 (CISPR11) EN55011 (CISPR11) EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Test Level / Note Test Level / Note Class B Class B Class A ----- EMC IMMUNITY EMC EMISSION EN55024 , EN60601-1-2, EN61204-3 Level 3, 8KV air ; Level 4, 8KV contact Level 3 Level 3 Level 2, 1KV/Line-Line Level 3 Level 4 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MPM-05-3.3 MPM-05-5 MPM-05-12 MPM-05-15 MPM-05-24 ±0.3% ±0.5% ±0.3% ±0.5% ±0.3% ±0.5% ±0.3% ±0.5% ±0.3% ±0.5% 100mVp-p100mVp-p 150mVp-p 150mVp-p 180mVp-p 5V3.3V 12V 15V 24V 1A1.25A 0.42A 0.33A 0.23A 0 ~ 1A0 ~ 1.25A 0 ~ 0.42A 0 ~ 0.33A 0 ~ 0.23A 5W4.1W 5W 5W 5.5W SOLDERING TEMPERATURE 260℃±5℃/10sec.max. M PM -05 seri es 0.035Kg; 270pcs/10.5Kg/0.97CUFT -40 ~ +100℃, 10 ~ 95% RH non-condensing μ μ File Name:MPM-05-SPEC 2017-08-08 5W High Reliable Green Medical Encapsulated Type
Output Derating VS Input Voltage INPUT VOLTAGE (VAC) 60Hz 80 10095 120115 160140 200180 240220 264 LOAD (%) 100 Derating Curve fosc : 100KHz M PM -05 seri es AMBIENT TEMPERATURE (℃) LOAD (%) (HORIZONTAL)-30 -20 -10 0 10 20 30 40 50 60 100 File Name:MPM-05-SPEC 2017-08-08 80 85 -40 FILTER I/P EMI FILTER RECTIFIERS RECTIFIERS CONTROL PWM DETECTION CIRCUIT FILTER -VSWITCHING POWER O.L.P. 5W High Reliable Green Medical Encapsulated Type
Please refer to : http://www.meanwell.com/manual.html M PM -05 seri es Mechanical Specification Case No.222A Unit:(mm) 3.5±1mm 21.5 3.6 38.5 45.7 3.4510.75 AC/L AC/N 1.04 3.45 25.4 SIDE VIEWBOTTOM VIEW File Name:MPM-05-SPEC 2017-08-08 5W High Reliable Green Medical Encapsulated Type