The MPB80 combines high density power and other standard features usually found in premium power systems. The low-profile package neatly fits 1U height constraints in an industry-standard 3" X 5" footprint. This Power Factor Corrected (PFC), multiple output product line features overvoltage and overcurrent protection. In addition to UL, CSA, and TÜV , regulatory agency compliances include the CE Marking and harmonic compliance to EN61000-3-2.
FEATURES
Power Factor Correction (PFC) Meets EN61000-3-2 Low-Profile Height Fits 1U Constraints High 3.3V and 5V Current Capabilities Available CE Marked to Low Voltage Directive Autoranging AC Input, 85-264 VAC Overvoltage Protection on the Main Output DUAL AND TRIPLE OUTPUT MODEL SELECTION CHART – UP TO 63W CONVECTION COOLED, UP TO 80W FORCED AIR COOLED (300 LFM) MODEL OUTPUT ADJUSTMENT CONVECTION FORCED AIR LINE TOTAL RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE COOLED CURRENT CURRENT REGULATION REGULATION mV (NOTE 1) ACCURACY +12V Fixed 0.5A/1A PK 1A 0.5% ±5% 1% 11.5V to 12.5V MPB80-3000 +12V Fixed 2.5A/3A PK 3A 1.5% -7%, +13% 1% 11.5V to 12.5V NOTES: 1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz. 2) MPB80-3300 has overvoltage protection on +3.3V and +5V outputs. SINGLE OUTPUT MODEL SELECTION CHART – UP TO 72W CONVECTION COOLED, UP TO 100W FORCED AIR COOLED (300 LFM) MODEL OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MPB80-1012 12V 11V to 13V 6A 8.4A 0.5% 1% 1% 11.94V to 12.06V MPB80-1024 24V 22V to 26V 3A 4.2A 0.5% 1% 1% 23.88V to 24.12V NOTES: 1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz. NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Po wer-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice. Rev. 10/2000
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 230 VAC. Varies with distribution of loads among outputs. 73 % Minimum Loads Single Output Models 0.0 Minimum load required on V1 for regulation of V2, V3. MPB80-2000 1.5 AmpsAll other Multiple Output Models 0.7 Ripple and Noise Full load, 20 MHz bandwidth See Model Selection Chart Output Power Convection cooled, continuous output power. MPB80-10XX 72 MPB80-2000 61 MPB80-3000 63 Watts MPB80-3300 43 Forced air cooled, 300 LFM, or convection cooled, peak MPB80-10XX 100 output power 10% duty cycle, 30 seconds maximum. MPB80-2000 80 MPB80-3000 80 Watts MPB80-3300 61 Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 2 % Regulation Varies by output. Total regulation includes: line changes from 85-132 VAC or See Model Selection Chart170-264 VAC, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 500 µS 5% max. deviation. Turn-On Delay Time required for initial output voltage stabilization. 2 Sec Turn-On Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS 12V 17.3 20.2 24V 32.2 37.8 48V 55.2 64.8 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload cond ition. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Autoranging AC input automatically adjusts, no manual strapping required. 85 264 VAC Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-Up Time After last AC line peak. Full load @ 120 VAC 16 mSFull load @ 220 VAC 20 Input Current Single Output Models, 120 VAC 1.5 ARMS Single Output Models, 230 VAC 0.75 Dual and Triple Output Models, 120 VAC 1.1 Dual and Triple Output Models, 230 VAC 0.55 Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC (one cycle). 32 A PK Operating Frequency Switching frequency of main transformer. 60 68 kHz
SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS AC Input Harmonic Distortion In compliance per EN61000-3-2. Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to output, 1 second. 2600 VDC Electromagnetic Interference, FCC CFR title 47 Part 15. B ClassConducted EN55022 / CISPR 22 B Input Transient Protection EN61000-4-5 class 3. 2 kV Insulation Resistance Input to output. 10 M Leakage Current Per EN60950, 264 VAC. 1.0 mA ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft.Non-Operating. 30k Cooling See model selection table for individual convection/forced air rating. Operating Temperature At 100% load. 0 50 °CDerate linearly above 50°C by 2% per °C. 0 70 Storage Temperature -40 85 °C Relative Humidity Non-condensing. 95 % Shock Peak acceleration. 20 G PK Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 G RMS MPB80 SERIES
COMPONENT HEIGHT: 1.26" (32.0mm) WEIGHT: 0.8 LBS (0.36 kg) INPUT CONNECTIONS, J1: MOLEX 26-60-4030 OR EQUIVALENT HEADER MATES WITH MOLEX HOUSING 09-50-3031 OR EQUIVALENT AND PINS 08-50-0106 (18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT. OUTPUT CONNECTIONS SIX CONNECTOR J2: MOLEX 26-60-4060 HEADER MATES WITH MOLEX 09-50-3061 OR EQUIVALENT AND PINS 08-50-0106 (18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT. SEVEN CONNECTOR J2: MOLEX 26-60-4070 HEADER MATES WITH MOLEX 09-50-3071 OR EQUIVALENT AND PINS 08-50-0106 (18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT. CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH. Input 2.550" (64.8mm) J3: 0.250 FASTON SAFETY EARTH GROUND L N 4.550" (115.6mm) 3.00" (76.2mm) 0.225" (5.7mm) 0.156" DIA THRU (3.96mm)
4 PLACES
0.225" (5.7mm) Output PIN 1 5.00" (127.0mm) PIN 1 PIN 1 PIN 1 RTN RTN RTN RTN RTN RTN RTN RTN MPB80-2000 MPB80-3000 MPB80-3300 MPB80-10XX PIN 1 RTN RTN RTN NC