MP EMERSON-NETWORKPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Technical Support: (888) 41ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662136 Special Features
- Current share on all outputs with ratings of 10 A or greater
- Remote sense on all outputs with ratings greater than 2 A
- Overload protection on all outputs
- Voltage adjustment on all outputs
- Margining on all single output modules
- Input OK signal and status indicator LED
- Global DC OK signal and status indicator LED
- Global and individual module inhibits/enable
- 2 year warranty
- Forced air cooling, field replaceable fan
- Isolated 5 V bias voltage
- Power factor correction
- EN61000-3-2 harmonic distortion compliance
- CISPR 22, EN55022 Curve B conducted / radiated EMI
- European CE Mark requirements
- Optional VME timing and system DC OK module
- Customer-provided air option
- Additional 200 W output @ high line (180-264 VAC)
- Low leakage option for medical applications
- EN61000 immunity standards
- Standard modification flexibility (consult factory) Low noise fan Fan fail signal Module enable Outputs down to 0.5V MP Series Operating temperature: -20°C to 50°C (start @ 0°C) (derate each output linearly to 50% at 70°C) (-20°C to 40°C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E Humidity: 95% non-condensing Storage temperature: -40°C to +85°C Temperature coefficient: 0.02% per °C Cooling: Internal DC fan or customer provided air (option) UL UL1950 CSA CSA22.2 No. 234 Level 5 IEC IEC950, Class 1 VDE EN60950, BABT Compliance to EN 60950, BS 7002 CB Certificate and report CE Mark Environmental Safety MP4 MP6 MP8 Rev 2.17.06 MP1 400-1200 Watts
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 137www.astecpower.com Electrical Specs Input Input voltage 85-264 VAC 120-350 VDC Frequency 47-440 Hz Inrush current 40 A peak max. (soft start) Efficiency 70-80% typ. @ full case load Power factor 0.99 typ. meets EN61000-3-2 Turn-on time AC on 1.5 sec typ., Inhibit / Enable 150 ms typ. EMI filter standard CISPR 22 EN55022 Level “B” EMI filter (low leakage option) CISPR 22 EN55022 Level “A” Leakage current standard 2.0 mA max. @ 240 VAC Leakage current (low leakage option). 300 μA max. @ 240 VAC Radiated EMI CISPR 22 EN55022 Level “B” Holdover storage 20 ms minimum (independent of input VAC) AC OK >5 ms early warning min. before outputs loose regulation Full cycle ride thru (50 Hz) Harmonic distortion Meets EN61000-3-2 Isolation Meets EN60950 Global Inhibit/Enable TTL, Logic “1” and Logic “0” Input fuse (internal) MP4: 10 A MP6: 15 A MP8: 20 A MP1: 20 A Warranty 2 years Output Adjustment range ±10% min. all outputs Margining ±4-6% nom. Overall reg 0.4% or 20 mV max. (36 W modules 4% max.) Ripple RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz Dynamic response <2% or 100 mV, with 25% load step. Recovery time To within 1% in <300 μsec. Overcurrent protection Single, main of dual output module 105-120% of rated output current. Aux output of dual output module 105-140% of rated output current. Triple output module internally protected Short circuit protection Protected for continuous short circuit Recovery is automatic upon removal of short. Overvoltage protection (measured at sense connection) Single output modules 2-5.5 V 122-134% 6-60 V 110-120% Dual output module 2-6 V 122-134% 8-28 V 110-120% Triple output module. No overvoltage protection provided. Recycle the AC input voltage to reset OVP circuit Reverse voltage protection 100% of rated output current Thermal protection All outputs disabled when internal temp exceeds safe operating range. >5 ms warning (AC OK signal) before shutdown Remote sense Up to 0.5 V total drop (not available on triple output module) Single wire parallel Current share to within 2% of total rated current DC OK -2% to -8% of nominal for any monitored output Minimum load Not required on single or triple output modules. 10% required on main of dual output modules Housekeeping bias voltage 5 VDC @1.0A mA max. present whenever AC input is applied Module inhibit TTL, isolated, singles and dual (both outputs) only Switching frequency 250 kHz Output/Output isolation >1 Megohm VME signal option board POR signal & quad external DC OK Hold-up module (HUP) 1-slot module providing an additional 34mSec (60mSec total) hold-up @ 600W loading. Power Derating Curve Rated Total Case Load Normal Air Flow 100 35 40 45 50 55 60 65 70 TA – Ambient Temperature – °C Notes: 1. Single output modules only. 2. Single and main of dual output modules only. 3. Contact factory for optional preload if required. MP Series
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662138 Common Examples and Specifications Voltage Voltage Single Output Dual Triple Code Module Code Output Output V1 V2 V1 V2 V3
2 V A 35A 60 A 120 A — 10 A — — 2 A
2.2 V B 35 A 60 A 120 A — 10 A — — 2 A
3 V C 35A 60 A 120 A — 10 A — — 2 A
3.3 V D 35 A 60 A 120 A — 10 A — — 2 A
5 V E 35A 60 A 120 A 10 A 10 A — — 2 A
5.2 V F 35 A 60 A 115 A — 10 A — — 2 A
5.5 V G 34 A 58 A 109 A — 10 A — — 2 A
6.0 V H 23 A 42 A 78 A — 10 A — — 2 A
8.0 V I 20 A 36 A 68 A — — 1 A 1 A 1 A
10 V J 18 A 32 A 60 A — — 1 A 1 A 1 A
11 V K 17 A 31 A 54.5 A — — 1 A 1 A 1 A 12V L 17A 30 A 50 A 10 A 4 A 1 A 1 A 1 A 14 V M 14 A 21 A 40.5 A 9 A 4 A 1 A 1 A 1 A
15 V N 14 A 20 A 39 A 8 A 4 A 1 A 1 A 1 A
18 V O 11 A 19 A 33.3 A — — — 0.5 A 0.5 A 20 V P 10.5 A 18 A 30 A — — — 0.5 A 0.5 A 24 V Q 8.5 A 15 A 23.5 A 4 A 2 A — 0.5 A 0.5 A 30 V S 6.5 A 12 A 20 A — — — — — 33 V T 6.2 A 10.9 A 18.2 A — — — — — 36 V U 5.8 A 10 A 16.6 A — — — — — 42 V V 4.2 A 7.5 A 12.5 A — — — — — 48 V W 4.0 A 7.5 A 12.5 A — — — — — 54 V X 3.7 A 6.0 A 11 A — — — — — 60 V Y 3.5 A 6.0 A 10 A — — — — — Non-std Z 2.4V-2.7V 35 60 120 — 10 — — 2 3.6V-4.5V 35 60 120 — 10 — — 2 6.6V-9.2V 20 36 68 10 4 — — 1 8.8V-9.0V 18 32 60 10 4 — — 1 Notes: 1 Takes up one slot. 2 T akes up two slots. 3 T akes up three slots. Modules Single Output Example Dual Output Example Triple Output Example Outputs Max output power Max output current Volts Standard voltage increments Remote sense on outputs Remote margin/V-Program Module inhibit (isolated) Single wire active current share Over voltage / Over current protection Minimum load required Slots occupied in any MP case SSiinnggllee DDuuaall TTrriippllee 11 2 3
210 W 360 W 600 W 144 W 36 W
35 A 60 A 120 A 10 A 2 A
2-60 V 2-60 V 2-60 V 2-28 V 2-28 V 25 25 25 19 18 Yes Yes Yes Yes, both No Yes Yes Yes No No Yes Yes Yes --- --- Yes Yes Yes Yes, main only --- Yes Yes Yes Yes Over current No No No Yes (10%), main only No 12 3 1 1 Modules Module Code Voltage Code
5 V @ 60A
12 V @ 10 A
5 V @ 10 A
12 V @ 1 A
20 V @ 0.5 A
5 V @ 2 A
Notes: 1. Total load not to exceed 144 W. 2. No module code required. 3. Total load not to exceed 36 W. Rev 6.28.05
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 MP Series EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 139www.astecpower.com MULTIPLE OUTPUTS Total Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Size Model Number Power (Volts/Amps) (inches) 400 W 5 / 60 3.3 / 35 12 / 1 12 / 1 12 / 1 — 2.5 x 5 x 10 MP4-2E-1D-LLL-00 400 W 24 / 15 12 / 17 5 / 35 — — — 2.5 x 5 x 10 MP4-2Q-1L-1E-00 400 W 5 / 60 12 / 17 12 / 10 5 / 10 — — 2.5 x 5 x 10 MP4-2E-1L-4LE-00 400 W 5 / 35 12 / 10 3.3 / 10 12 / 1 12 / 1 5 / 2 2.5 x 5 x 10 MP4-1E-4LD-LLE-00 600 W 3 / 60 5 / 60 12 / 10 12 / 4 — — 2.5 x 5 x 11 MP6-2C -2E-4LL-00 600 W 5 / 120 12 / 17 12 / 10 5 / 10 — — 2.5 x 5 x 11 MP6-3E-1L-4LE-00 600 W 12 / 30 5 / 35 — — — — 2.5 x 5 x 11 MP6-2L-1E-00 800 W 36 / 16.6 24 / 4 5 / 10 12 / 10 12 / 4 — 2.5 x 7 x 10 MP8-3U-4QE-4LL-00 800 W 5 / 120 3.3 / 35 12 / 17 12 / 10 12 / 4 — 2.5 x 7 x 10 MP8-3E-1D-1L-4LL-00 800 W 15 / 20 5 / 35 15 / 14 24 / 8.5 15 / 8 5 / 10 2.5 x 7 x 10 MP8-2N-1E-1N-1Q-4NE-00 800 W 2 / 180 5 / 60 — — — — 2.5 x 7 x 10 MP8-3A-2A-2E-30 1000 W 3.3 / 120 5 / 120 — — — — 2.5 x 8 x 11 MP1-3D-3E-00 SINGLE OUTPUTS Total Output Size Model Number Power (Volts/Amps) (inches) 360 W 2 / 180 2.5 x 5 x 10 MP4-3A-2A-30 400 W 5 / 80 2.5 x 5 x 10 MP4-3E-00 - 429 600 W 2 / 275 2.5 x 8 x 11 MP6-3A-3A-1A-90 600 W 5 / 120 2.5 x 5 x 11 MP6-3E-00 600 W 48 / 12.5 2.5 x 5 x 11 MP6-3W-00 800 W 5 / 160 2.5 x 7 x 10 MP8-3E-2E-30 - 415 800 W 48 / 16.6 2.5 x 7 x 10 MP8-3W-1W-30 1000 W 5 / 200 2.5 x 8 x 11 MP1-3E-3E-30 - 404
Ordering Information
Parallel Codes* 7 6 5 4 3 2 1 0 = no parallel 1 = 1 & 2 2 = 2 & 3 3 = 3 & 4 4 = 4 & 5 5 = 3 & 4 & 5 6 = 5 & 6 7 = 4, 5 & 6 8 = 6 & 7 9 = 3 & 4, 6 & 7 MP4 & MP6 available slots MP8 available slots *For custom parallel configurations contact Astec Power Technical Support. Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 1 Slot 2 Slot 3 Slot 4 Slot 6 Slot 7 Slot 5 MP1 available slots Parallel Code: Slot #1 Slot #2 Slot #3 Slot #4 Use Only for Modified Standard Slot #5 2 or 3 digit code See previous page. (MP8 & MP1 Only) Slot #6 Use “— ” for Standard Remote Sense U s e“/” After any module using Remote Sense with or-ing diode (redundancy) (MP1 Only) Slot #7 IINN PPUUTT CCaassee SSiizzee ((iinncchheess)) SSlloottss 8855--226644 VVAACC 118800--226644 VVAACC 44 = 2.5 x 5 x 10 5 available slots 400 W max. 600 W max. 66 = 2.5 x 5 x 11 5 available slots 600 W max. 800 W max. 88 = 2.5 x 7 x 10 6 available slots 800 W max. 1000 W max. 11 = 2.5 x 8 x 11 7 available slots 1000 W max.* 1200 W max. **11220000 WW mmooddiiffiiccaattiioonn aavvaaiillaabbllee aatt hhiigghh lliinnee ooppeerraattiioonn Option Code: 0 = no options 1 = rear air exhaust 3 = global enable 5 = option package (options 1 & 3) M =l o w l e a k a g e N = low leakage plus option 1 P = low leakage plus option 3 R = low leakage plus option 5 Notes: 1. Omit digits that do not apply. 2. Specify modules from lowest number of outputs to highest. (Single/Dual/Triple) 3. If number of outputs are equal, specify modules from highest to lowest power increments. If power increments are equal, specify in descending alphabetical order (1A, B, C . . .). 4. Always start with Slot 1. 5. All MP model configurations created using this selection guide are standard MP products with standard availability and lead times. 6. Optional VME/DCOK module must always be located in the last slot. Module designator is “VME”. Slot 3 Output 2:12 V @ 17 A Slots 1 & 2 Output 1:5.2 V @ 60 A 2.5” x 7” x 10” (6 slots available) No Paralleling Low Leakage Slot 4 Output 3:12 V @ 10 Output 4: 5 V @ 10 A Slot 5 Output 5: 12 V @ 1 A Output 6:12 V @ 1 A Output 7: 5 V @ 2 A MP8- 2 F / 1 L - 4 L E - L L E -VME -0M-XXX EXAMPLE VME Card Factory assisted code for modifications -HUP Hold-up Module
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662140 Drawings DC-DC Converter Output Modules Control Signal Information, J1 Control Connector Pin No. Function 1 + Remote Sense single or dual o/p main 2 Remote Margin / V. Program single o/p
3 Margin High single o/p
4 - Remote Sense / Margin Low single or dual o/p main
5 Spare
6 Module, Isolated Inhibit single or dual o/p
7 Module Inhibit return single or dual o/p
8 Current Share (SWP) single or dual o/p main
9 + Remote Sense V2 dual o/p, single is spare 10 - Remote Sense V2 dual o/p, single is spare V2 ADJ V1 ADJ PIN 1 V3 ADJ DC OUTPUT CONNECTION .48 (12.1) V1+ V1- V2+ V2- V3+ V3- .84 (21.3) PIN 1 M4X8 SCREWS (4X) V ADJ .32 (8.1) .44 (11.3) (2X) (2X) .33 (8.5) .63 (16.0) M4X8 SCREWS (4X) PIN 1 V ADJ .44 (11.3) .32 (8.1) 1.24 (31.6) (2X) .61 (15.6) (2X) .63 (16.0).59 (15.0) PIN 1 .32 (8.1) .44 (11.2 ) (2X) M4X8 SCREWS (2X) V ADJ .48 (12.1) .44 (11.3) 1.38 (35.1) PIN 1 V2 ADJ .32 (8.1) .42 (10.7) V1 + V1 - V2 - V2 + M3X8 SCREWS (4X) .46 (11.7) (4X) .30 (7.5)(3X) V1 ADJ 1.17 (29.7) Single 210 Watt Dual 144 Watt Triple 36 Watt Single 360 Watt Single 600 Watt MP MODULES
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 MP Series EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 141www.astecpower.com 19.05 .750 171.45 6.750 29.05 1.144 171.45 6.750 A A A B B BB M4 MTG HOLES 4 PL MARKED "B" #8-32 MTG HOLES 4 PL MARKED "A" 101.60 4.000 12.70 .500 Standard Airflow +-+- +.0 -.5254.0 +.00 -.0210.00 3.7 .15TYP 19.05 .750 +.0 -.563.5 +.00 -.02 2.50 3.5 .14 (TYP) M4 MTG HOLES 4 PL MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES 17.3 1.0 .68 .04 171.45 6.750 38.10 1.500 12.70 .500MP4 +.0-.5279.4 +.00 -.0211.00 MP6 +.0 -.5127.0 +.00 -.02 5.00 19.0 .75 49.2 1.94 -A-(4 PL) NON-CUMULATIVE 4.3 .8 .17 .03 23.9 .5 .94 .02 S L O T S L O T S L O T S L O T S L O T 5 4 32 1 Notes 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2 110 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pin s, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045” square pins on .156” centers. Mates with Molex 09-50-8063 or equivalent. MP Series MP4 (400/600 Watts Max) MP6 (600/800 Watts Max) 55--IInncchh CCaassee SSiizzee:: MP4: 2.5” x 5” x 10” (63.5mm x 127mm x 254mm) 55--IInncchh CCaassee SSiizzee:: MP6: 2.5” x 5” x 11” (63.5mm x 127mm x 279.4mm) 144 W Dual: 0.6 lb. PFC Input Information J1 Control ConnectorStandard for all cases Pin No. Function J1-1 Input AC OK - “Emitter” J1-2 Input AC OK - “Collector” J1-3 Global DC OK - “Emitter” J1-4 Global DC OK - “Collector” J1-5 Spare J1-6 Global Inhibit/Optional Enable Logic “0” J1-7 Global Inhibit/Optional Enable Logic “1” J1-8 Global Inhibit/Optional Enable Return J1-9 SELV 5V Housekeeping J1-10 SELV 5V Housekeeping Return
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662142 Drawings 59.5 2.34 60.5 2.38 D OUTPUT MODULE AREA M4 MOUNTING HOLES (4X) 171.45 6.75 19.05 0.7 14.0 0.55 14.7 0.58 38.10 1.5 AC INPUT S L O T S L O T S L O T S L O T S L O T S L O T 31.8 1.25 35.0 1.38 19.05 0.75 171.45 6.75 29.05 1.1 171.45 6.75 12.70 0.5 M4 MOUNTING HOLES #8-32 MOUNTING HOLES MARKED "A" (4X) "A" "A" "A" "A" "B" "B" MARKED "B" (4X) "B" "B" 152.40 6.0 12.70 0.5 254 10.0 177.8 7.0 63.5 2.5 63.5 2.5 177.8 7.0 254 10.0 Standard Airflow MP Series MP8 (800/1000 Watts Max) 77--IInncchh CCaassee SSiizzee:: MP8: 2.5” x 7” x 10” (63.5mm x 177.8mm x 254mm) Notes 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-21 10 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins , Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045” square pins on .156 centers. Mates with Molex 09-50-8063 or equivalent.
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 MP Series EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 143www.astecpower.com 88--IInncchh CCaassee SSiizzee:: MP1: 2.5” x 8” x 11” (63.5mm x 203.2mm x 279.4mm) W Single: 1.0 lb. • 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb. Notes 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-21 10 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating (conductive. 4. All dimensions are in millimeters and inches, and are typical. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045” square pins on .156 centers. Mates with Molex 09-50-8063 or equivalent. MP Series MP1 (1000/1200 Watts Max)