MP5000S MPS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 13

Technical content

12V, 5A Programmable Current Limit Switch MP5000S Rev. 1.0 www.MonolithicPower.com 1 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved.

DESCRIPTION

The MP5000S is a protection device designed to protect circuitry on the output ( source) from transients on input (VCC). It also protects VCC from undesired shorts and t ransients coming from the source. At start up, inrush current is limited by limiting the slew rate at the source. The slew rate is controlled by a small capacitor at the dv/dt pin. The dv/dt pin has an internal circuit that allows the customer to float this pin (no connect) and still receive 0.9ms ramp time at the source. The maximum load at the output (source) is current limited. This is accomplished by utilizing a sense FET topology. The magnitude of the current limit is controlled by an external resistor from the I-Limit pin to the Source pin. An internal charge pump drives the gate of the power device, allowing a very low on -resistance DMOS power FET of just 40mΩ. The source is protected from the V CC input being too low or too high. Under Voltage Lockout (UVLO) assures that V CC is above the minimum operating threshold, before the power device is turned on. If V CC goes above the high output threshold, the source voltage will be limited.

FEATURES

 Integrated 40mΩ Power FET  Enable/Fault Pin  Adjustable Slew Rate for Output Voltage  Adjustable Current Limit: 1-5A  Thermal Protection  Over Voltage Limit

APPLICATIONS

 Hot Swap  PC Cards  Laptops TYPICAL APPLICATION All MPS parts are lead-free and adhere to the RoHS directive. For MPS green status, please visit MPS website under Products, Quality Assurance page. “MPS” and “The Future of Analog IC Technology” are registered trademarks of Monolithic Power Systems, Inc.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 2 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved.

ORDERING INFORMATION

Part Number* Package Top Marking MP5000SDQ QFN10 (3 x3mm) ADT * For Tape & Reel, add suffix –Z (e.g. MP5000SDQ–Z); For RoHS Compliant Packaging, add suffix –LF (e.g. MP5000SDQ–LF–Z) PACKAGE REFERENCE ABSOLUTE MAXIMUM RATINGS (1) Continuous Power Dissipation (TA = +25°C) (2) Operating Junction Temperature . -40C to 150C Recommended Operating Conditions (3) Input Voltage Operating Range…….10V to 18V Continuous Current Operating Junction Temp. (TJ). -40°C to +125°C Thermal Resistance (4) θJA θJC Notes: 1) Exceeding these ratings may damage the device. 2) The maximum allowable power dissipation is a function of the maximum junction temperature T J(MAX), the junction -to- ambient thermal resistance θ JA, and the ambient temperature TA. The maximum allowable continuous power dissipation at any ambient temperature is calculated by PD(MAX)=(TJ(MAX)- TA)/ θJA. Exceeding the maximum allowable power dissipation will cause excessive die temperature, and the regulator will go into thermal sh utdown. Internal thermal shutdown circuitry protects the device from permanent damage. 3) The device is not guaranteed to function outside of its operating conditions. 4) Measured on JESD51-7, 4-layer PCB.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 3 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved.

ELECTRICAL CHARACTERISTICS

VCC = 12V, RLIMIT=22Ω, Capacitive Load = 100μF, TA=25°C, unless otherwise noted. Parameters Symbol Condition Min Typ Max Units Power FET Delay Time tDLY Enabling of chip to ID=100mA with a 1A resistive load 0.1 ms ON Resistance (5) RDSon TJ=25°C 40 55 mΩ TJ=85°C 52 Off State Output Voltage VOFF VCC=18Vdc, V ENABLE=0Vdc, RL= 500Ω 120 mV Thermal Latch Shutdown Temperature(5) TSD 175 °C Under/Over Voltage Protection Output Clamping Voltage VCLAMP Overvoltage Protection VCC=17V 13.8 15 16.2 V Under Voltage Lockout VUVLO Turn on, Voltage going high 7.7 8.5 9.3 V Under Voltage Lockout (UVLO) Hysteresis VHYST 0.80 V Current Limit Hold Current (6) ILIM-SS RLIM=22Ω 2.4 3.7 5.0 A Trip Current ILIM-OL RLIM=22Ω 5.0 A dv/dt Circuit Rise Time Tr Float dv/dt pin, Enable to VOUT=12V 0.5 0.9 2.1 ms Enable/Fault Low Level Input Voltage VIL Output Disabled 0.5 V Intermediate Level Input Voltage VI (INT) Thermal Fault, Output Disabled 0.82 1.4 1.95 V High Level Input Voltage VIH Output Enabled 2.5 V High State Maximum Voltage VI (MAX) 5 V Low Level Input Current (Sink) IIL VENABLE=0V -28 -50 μA Maximum Fanout for Fault Signal Total number of chips that can be connected for simultaneous shutdown

3 Units

Maximum Voltage on Enable /Fault Pin(7) VMAX VCC V Total Device Bias Current IBIAS Device Operational 1 1.2 mA Thermal Shutdown 0.4 Minimum Operating Voltage for UVLO VMIN Enable<0.5V 5 V Notes: 5) Guaranteed by design. 6) Guaranteed by characterization Test. 7) Maximum Input Voltage on Enable pin to be ≤ 6.0V if Vcc ≥ 6.0V, Maximum Input Voltage on Enable pin to be Vcc if Vcc ≤ 6.0V.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 4 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. PIN FUNCTIONS Pin # Name Description 1 GND Negative Input Voltage to the Device. This is used as the internal reference for the IC. 2 dv/dt The internal dv/dt circuit controls the slew rate of the output voltage at turn on. It has an internal capaci tor that allows it to ramp up over the period of 0.9ms. An external capacitor can be added to this pin to increase the ramp time. If an additional time delay is not required, this pin should be left open.

3 Enable/Fault

The Enable/Fault pin is a tri -state, bi-directional interface. It can be used to enable the output of the device by floating the pin, or disable the chip by pulling it to ground (using an open drain or open collector device ). If a thermal fault occurs, the voltage on this pin will go to an intermediate state to signal a monitoring circuit that the device is in thermal shutdown. See text: “ENABLE/FAULT PIN”.

4 I-Limit A resistor between this pin and the Source pin sets the overload and short circuit

current limit levels. 5 N/C DO NOT CONNECT. Pin must be left floating. 6-10 SOURCE This pin is the source of the internal power FET and the output terminal of the IC.

11 VCC

(Exposed Pad) Positive input voltage to the device (exposed pad).

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 5 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. TYPICAL PERFORMANCE CHARACTERISTICS VIN = 12V, VEN=3.3V, RLIMIT=22Ω, COUT=10uF, Cdv/dt=1nF, TA=25°C, unless otherwise noted.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 6 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. TYPICAL PERFORMANCE CHARACTERISTICS (continued) VIN = 12V, VEN=3.3V, RLIMIT=22Ω, COUT=10uF, Cdv/dt=1nF, TA=25°C, unless otherwise noted.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 7 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. TYPICAL PERFORMANCE CHARACTERISTICS (continued) VIN = 12V, VEN=3.3V, RLIMIT=22Ω, COUT=10uF, Cdv/dt=1nF, TA=25°C, unless otherwise noted.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 8 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. BLOCK DIAGRAM Figure 1—Function Block Diagram

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 9 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. OPERATION The MP5000S is designed to limit the in -rush current to the load. It offers an integrated solution to monitor t he input voltage, output voltage, output current and die temperature. Under Voltage Lock Out Operation If the supply (input) is below the UVLO threshold, the output is disabled, and the fault line is driven low. When the supply goes above the UVLO threshold, the output is enabled and the fault line is released. When the fault line is released it will be pulled high by a 2 8uA current source. No external pull up resistor is required. In addition, the pull up voltage is limited to 5 volts. Output Over Voltage Protection If the input voltage is higher than the OVP threshold, the output will be clamped at 15V (typical). Current Limit When the part is active, if load reaches trip current (minimum threshold current triggering over current protection) or a short is present, the part switches into to a constant -current (hold current) mode. Part will be shutdown only if the over current condition stays long enough to trigger thermal protection. However, when the part is powered up by V CC or EN, the load current should be smaller than hold current. Otherwise, the part can’t be fully turned on. In a typical application using a current limit resistor of 22Ω, the trip current will be 5A and the hold current will be 3.7A. If the device is in its normal operating state and p assing 2.0A it will need to dissipate only 1 60mw with the very low on resistance of 4 0mΩ. For the package dissipation of 50°C/Watt, the temperature rise will only be + 8°C. Combined with a 25°C ambient, this is only 33°C total package temperature. During a short circuit condition, the device now has 12V across it and the hold current clamps at 3.7A and therefore must dissipate 44W. At 50°C/watt, if uncontrolled, the temperature would rise above the MP5000S thermal protection (+175°C) and shutdown the devi ce to cause the temperature to drop below a hysteresis level. Proper heat sink must be used if the device is intended to supply the hold current and not shutdown. Without a heat sink, hold current should be maintained below 250mA at + 25°C and below 150mA at +85°C to prevent the device from activating the thermal shutdown feature. Thermal protection When thermal protection is triggered, the output is disabled and the fault line is driven to the middle level. The thermal fault condition is latched, and the p art will remain latch off state until restart the power or reset the enable pin. Enable / Fault Pin The Enable /Fault Pin is a Bi-Directional three levels I/O with a weak pull up current (28uA typical). The three levels are low, mid and high. It functions to enable/disable the part and to relay Fault information. Enable/Fault pin as an input: 1. Low and mid disable the part. 2. Low, in addition to disabling the part, clears the fault flag. 3. High enables the part (if the fault flag is clear). Enable/Fault pin as an output: 1. The pull up current may (if not over ridden) allow a “wired nor” pull up to enable the part. 2. An under voltage will cause a low on the Enable/Fault pin, and will clear the fault flag. 3. A thermal fault will cause a mid level on the Enable/Fault pin, and will set the fault flag. The Enable/Fault line must be above the mid level for the output to be turned on. The fault flag is an internal flip-flop that can be set or reset under various conditions: 1. Thermal Shutdown: set fault flag 2. Under Voltage: reset fault flag

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000S Rev. 1.0 www.MonolithicPower.com 10 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. 3. low voltage on Enable/Fault pin: reset fault flag 4. mid voltage on Enable/Fault pin: no effect Under a fault, the Enable/Fault pin is driven to the mid level. There are 4 types of faults, and each fault has a direct and indirect effect on the Enable/Fault pin and the internal fault flag. In a typical application there are one or more of the MP5000S chips in a system. The Enable/Fault lines will typically be connected together. Table 1—Fault Function Influence in Application Fault description Internal action Effect on Fault Pin Effect on Flag Effect on secondary Part Short/over current Limit current none none none Under Voltage Output is turned off Internally drives Enable/Fault pin to Logic low Flag is reset Secondary part output is disabled, and fault flag is reset. Over Voltage Limit output voltage None None None Thermal Shutdown Shutdown part The part is latched off until a UVLO or externally driven to ground. Internally drives Enable/Fault pin to mid level Flag is set Secondary part output is disabled.

MP5000S – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH NOTICE: The information in this document is subject to change without notice. Users should wa rrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS products into any application. MPS will not assume any legal responsibility for any said applications. MP5000S Rev1.0 www.MonolithicPower.com 13 4/29/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved.

PACKAGE INFORMATION

QFN10 (3 x 3mm)