MP2.5CP HIROSE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

MF SERIES | : | CO-AXIAL._ CONNECTORS Overview The MP (Micro Push-on) series is a series of ultra-small-size 7592 coaxial connectors which were developed by mobilizing our company’s outstanding technical abilities to meet the requirements of high-density mounting, smaller size and lighter weight, and adoption of unit structures and improved performance characteristics. These requirements have been demanded in various devices recently. The “‘push-on” system has been adopted in the MP series, and size-wise the connectors in this series have an ultraminiaturized design which is believed to be the ultimate for any 75Q. coaxial connectors. The “one-touch solderless” technique is used in the outer conductors, aiming at attaining epoch-making improvements in the wiring connection, which was the biggest problem in high-frequency connectors in the past. The matching cables are 2.5C-XW (Irrax cables) and 2.5C-2W. They can be used in the frequency bands of 140MHz or lower, which are ordinarily called the intermediate- frequency bands, but they are suitable for various types of microwave communications equipment, various types of radio equipment, satellite communications equipment, measuring instruments, etc. ay -_ a i Y @ oa 3a ® ee . oy LC } a Characteristic Compact in size and lightweight Features They are extremely compact in size and lightweight. The plugs have a maximum outside diameter of 8.7 and an overall length of 16.5mm, and the receptacles have a maximum outside diameter of 10¢ and an overall length of 15.4mm. Thus, they are most suitable for high-density mounting. The receptacles are of the bulkhead type, which can be mounted from either the front or the rear of the panel. Good performance characteristics, high reliability The MP series consists of products that were developed from the beginning on the basis of cost effectiveness with low total cost. This includes good performance character- istics, high reliability and good workability. Their electrical and mechanical perform- ance characteristics and their resistance to vibration have been confirmed, and their excellence is guaranteed. In particular, since their opening parts are covered with outer cylinders, they have a reliability against twisting which is several stages superior to that of the small size coaxial connectors of the past. Superior connection of wiring The one-touch solderless system has been adopted for connecting the wiring. In order to deal with the difficulties of handling (following the miniaturization of the in- dividual parts) the units have been organized in blocks as much as possible, and case of handling has been set as a goal. Thanks to this new system, inconsistencies in the work of connecting the wiring from one operator to another are eliminated, and high reliability is ensured. In addition, thanks to the adoption of this connecting system, the connecting time has been greatly reduced to a fraction of that needed in the connectors of the past. 121

MP SERIES R | CO-AXIAL._ CONNECTORS Types The part numbers in the MP series have the following configuration: MP 2.5C P. Lsnatootes the shape of the connector. (Note) Indicates the matching cables. Indicates the name of the type. (Note) P indicates “plug.” R indicates “receptacle.” LP indicates “L-type plug.” LR indicates ‘L-type receptacle.” RP indicates “‘receptacle-type plug.” PA-JJ indicates a panel adapter with an opening part with jacks on both ends. P75 indicates a plug-type 75Q dummy load (terminator). ( Main materials used Main performance characteristics a Tetrafluoride resin ere 100M. or less at 500V DC [we | Nl i Cable connectors A large number of cables are conceivable as the matching cables for the connectors, but connectors which can be used with 2.5C-XW (Irrax cables) and 2.5C-2W are manu- factured as the standard products, taking into consideration the double braiding of their outer conductors, which results in little high-frequency leakage. Outer Outer | Outer i Type of diameter | diameter | diameter | “XIU | Insulation | Characteristié cable of center of ofouter | onter | material impedance conductor | insulation | conductor Irrax 2.5C-XW 40.01 3.56 a 0.409 4.56 (Irradiated 752 (Irrax cable) (Double) polyethylene) ( Baca | oaog-2! [a | (oat Poweuviene Use cables having the dimensions in the table above. 122

«[cizes-coora | wa.scr [ae winn.2.scaw| Pla | y i it MP2.5CP Le + [izas-00055 [ura sori | 2 Se-nwti 2 6¢-2W [0.5~Inwn] Poet 5 8 .1--: ‘ ear hs. st MP2.5CPJ LIC i AS ee «[i3250009-6 | wea scuF | 6c-aw'es 2.56307 [ype ah MP2.5CLP Receptacles es aa iT at olen S\\" soft IIMHUT Tf $ MP2.5CR A TEE tei : POLLS *Standard product | 123

A> ee et Depth s ke 2 [sie 15 EEEI--+ Hesr@] bese ble [ babes | Receptacle plug a MP2.5CRP . \\ Adapter \\ N . ra Me i a a1.5 alien 7 i i T S iodo, UL Accessories SO — oe MP2.5CP7 essssal Jit 124 “Standard product

MP SERIES | v/ CO-AXIAL CONNECTORS Connecting Methods Circuit diagrams of MP2.5CP, MP2.5CPJ | Circuit diagrams of MP2.5CLP nes ing cables as shown in Fig. 1. ["ea.4 1) Process the ends of the match- | msl Note 1) Be sure not to disentangle poof eS ing cables as shown in Fig, 1. ee the outer conductor. —_ Note 1) Be sure not to disentangle eee {oS the outer conductor. outer/ Outer Center 2. Connecting the wiring of 4 covering conductor/ Conductor the center conductor. . . Fig.2 | Gufer Outer Center 2 Connecting the wiring of the through the cable, in that order. Insulation 1) Pass the tubing and solderless 2) Insert the cable into the end- sleeve through the cable, in that cord pipe block. order. Fig. 2 3) Insert the sleeve until it strikes 2) Insert the cable into the shell against the end-cord pipe block, proper. Soldering as shown in Fig. 2. Fig. 2 3) Insert the solderless sleeve until 4) Solder the center conductor to wpet-e it strikes against the shell pro- the end as shown in Fig. 2. Caulking here must per, as shown in Fig, 2. Note 1) Pull the cable slightly be no gap . a _ S% : 4) Perform hexagonal caulking on Tubing End-cord pipe (about 50g) in order ‘to Be the solderless sleeve with the Sleeve block check the connections of | era dedicated fixture (MP-T-2), as the wiring, TSS shown in Fig. 2. 3. Connecting the wiring of the Tubing? / [| | There must the shell block as far as the 1) Solder the center conductor to be no gap yet prescribed position. the contact. ; —) hei 2) Perform hexagonal crimping on 2) Screw the screw cover into the | ae the connector shell with the shell proper. , =e dedicated fixture (MP-T-2), as section 1) Pass the tubing through the iT 2) Rane peneam in Fg 8. connector, as shown’ in Fig. 4, cr eA ply heat by means of a hair 2) Apply heat by means of a hair a dryer or the like in order to 1 25) he tubing to shrink Fig. 4 dryer or the like in order to = cause t z = cause the tubing to shrink. [|| TT | Note 1) In the case of MP2.5CPU, or a bring the tubing into con- Vel J tact with the collar and Tubing apply heat. Drawings of holes drilled to mount on panel Crimp Tool MP2.5CR-MP2.5CPJ-MP2.5CRP-MP2,5CPA-JJ Se 1st3? MP-T-3 aL : bo (for outer conductor) qat New type with ratchet mechanism a «leo Q if i MP2.5CLR gto. gi iE 4.5 4.5. Fo. V1 po t0.1 125