MP014100 MULTICOMP | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

  • Meets electrical performance specifications for intrinsically safe (EN60079-11) applications.
  • Fast-acting, high interrupting rating of 4000A at 250V AC/DC.
  • Ceramic tube, silver plated brass end cap construction.

Description

This Series fuse is designed for barrier circuits in intrinsic safety applications relating to Hazardous Locations. Ranging from 40mA to 250mA, the Series provides overcurrent protection solutions to fit many Hazardous Location barrier applications. Specifications Operating Temperature : -55°C to 125°C Storage Conditions : +10°C to +60°C Relative humidity : ≤ 75% yearly average without dew, maximum 30 days at 95% Vibration Resistance : 120 cycles in 1 direction at 1 min. each 10-55Hz, 3 directions (X, Y, Z) in total According to MIL-STD-202 Method 201A Recommended Land Pattern Dimensions : Millimetres Mechanical Specifications Dimensions

Page <2> V1.002/07/24 Cartridge Fuses Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Rated Current 110 % 300% 1000% 40mA~250mA >4h <10s <2ms Electrical Specifications Time vs Current Characteristics Table (measured with constant current power supply)

Electrical characteristics

Electrical Characteristics at 25°C Amp Code Rated Current Max Voltage Breaking Capacity Typical Melting I²t (A²sec) Typical Cold Resistance (mΩ) Color Code MP014098 40mA 250V AC 250V DC 4000A@250V AC 4000A@250V DC 0.00006 14.2 Grey MP014099 50mA 0.00010 9.4 Red MP014100 63mA 0.00012 8.8 Pink MP014101 80mA 0.00018 5.1 Green MP014102 100mA 0.00087 2.87 Yellow MP014103 125mA 0.00134 2.2 Orange MP014104 160mA 0.00166 2.05 Violet MP014105 200mA 0.00237 1.01 Brown MP014106 250mA 0.00530 0.71 Black Notes: (1) DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25°C (2) Typical Pre-arcing I2t are measured at 10In current. Temperature Derating Curve Normal ambient temperature: 23 ±3°C Operating temperature: -55°C to 125°C, with proper correction factor applied

Page <3> V1.002/07/24 Cartridge Fuses Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Average Time Current (I-T) Curves Soldering Parameters 1.Infrared Reflow: Temperature:260°C Time:30sec Max. Recommend reflow profile 2.Wave Soldering Reservoir Temperature:260°C Time in Reservoir:10sec Max. Profile Feature Lead (Pb)free solder Average Ramp-UP Rate (Tsmax to Tp) 3°C/s Max. Preheat and soak Temperature min.(Tsmin) 150°C Temperature max.(Tsmax) 200°C Time (Tsmin to Tsmax)(ts) 60~120s Liquidous temperature(TL) Time at liquidous(tL) 217°C 60~150s Peak package body temperature(Tp) 260°C Time (tP) within 5°C of the specified classification temperature (Tc) 30s Average ramp-down rate (Tp to Tsmax) 6°C/s Max. Time (25°C to Peak Temperature) 8 Minutes Max.

Page <4> V1.002/07/24 Cartridge Fuses Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019. Part Number Table Description Part Number Surface Mount Barrier Network Fuses, 40mA, 250V AC/DC MP014098 Surface Mount Barrier Network Fuses, 50mA, 250V AC/DC MP014099 Surface Mount Barrier Network Fuses, 63mA, 250V AC/DC MP014100 Surface Mount Barrier Network Fuses, 80mA, 250V AC/DC MP014101 Surface Mount Barrier Network Fuses, 100mA, 250V AC/DC MP014102 Surface Mount Barrier Network Fuses, 125mA, 250V AC/DC MP014103 Surface Mount Barrier Network Fuses, 160mA, 250V AC/DC MP014104 Surface Mount Barrier Network Fuses, 200mA, 250V AC/DC MP014105 Surface Mount Barrier Network Fuses, 250mA, 250V AC/DC MP014106