Medical Grade 150 Watt Enclosed Switching Power Supplies m m k 1 5 0 s s e r i e s 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181WWW.AsTRODYNE.COm Universal 88-264VAC Auto Range Input Compact Footprint High Efficiency Regulated Outputs 4000V Isolation Built in EMI Filter model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ MMK150S-5 5 VDC 30 100mv MMK150S-12 12 VDC 12.5 100mv MMK150S-15 15 VDC 10 100mv MMK150S-24 24 VDC 6 100mv 3.5”W x 6”L x 1.75”H Order On-Line! astrodyne.com
Medical Grade 150 Watt Enclosed Switching Power Supplies m m k 1 5 0 s s e r i e s 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181WWW.AsTRODYNE.COm INPUT sPECIFICATIONs Input Voltage Range 88-132/176-264 VAC Auto Voltage Select Frequency Range 47-63 Hz Inrush Current, typ: 20A @ 100VAC * 40A @ 200VAC * OUTPUT sPECIFICATIONs Voltage and Current See Selection Chart Line/Load Regulation (10%-FL) ± 0.5%, typ Voltage Tolerance ± 1%, typ DC Voltage Adjust (typ) ± 6%, typ Temperature Coefficient ± 0.03%/°C Ripple/Noise 100mV, typ Over Voltage Protection 130%, Latching, Re-power * Short Circuit Protection 160%, Indefinite Hold Up Time 20mS, typ (Nom I/P, FL) Turn On Time ≤ 1.0 sec, typ Rise Time ≤ 20 msec, typ Over/Under Shoot < 10% of FS Leakage Current ≤ 0.3 mA @ 240VAC, 50 Hz GENERAL sPECIFICATIONs Isolation I/P-O/P: 4000VAC I/P-Ground: 1500VAC O/P-Ground: 500 VAC Efficiency 78%, typ Switching Frequency 100Khz, (fixed, typical) Safety UL60601-1, EN60601-1, IEC60601-1 ENVIRONmENTAL sPECIFICATIONs Oper. Temperature 0 to +60°C (See Derate Curve) Storage Temperature -25 to +85°C * Relative Humidity 10% to 90%, non-cond * EMI (Designed to Meet) EN55011, Class B MTBF 100,000 Hrs Mil Std 217, 25°C PHYsICAL sPECIFICATIONs Size 6” x 3.5” x 1.75” Construction Enclosed Weight 1.37 lb, (630g) * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
Medical Grade 150 Watt Enclosed Switching Power Supplies m m k 1 5 0 s s e r i e s 300 myles standish Blvd., Taunton, mA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181WWW.AsTRODYNE.COm OUTPUT DERATING CURVE mECHANICAL DImENsIONs Pin # Outputs
1 ACN
2 ACL
3 GND
Load, % Ambient Temp, C 0 5 10 15 20 25 30 35 40 45 50 55 60 100 120 22CFM Forced Air - All Outputs (Recommended) 12/15/24VDC Outputs, Convection Cooled 5VDC Output, Convection Cooled (Forced air cooling direction: Straight down from top of unit) PLEASE NOTE: To improve specifications and safety isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit