Features

  • Designed for use with NiH battery cells on spacecraft
  • Thermally activated non-dissipative permanent battery bypass
  • Charge/discharge diodes are replaced by a permanent low resistance short to bypass cell after open failure
  • Compact, rugged construction offers weight and cost savings
  • Can modify leads, available in different lengths
  • Radiation tolerant to 300 Mrad total dose
  • Discrete diodes screened and qualified per Microsemi PS11.50
  • Multiple shorting points for redundant short activation PART NUMBER SYMBOL MAX. UNIT Discharge Current ID 200 Amps Charge Current IC 50 Amps Non-Rep Peak Surge Current (discharge) IDSM 1000 Amps Non-Repetitive Peak Surge Current (charge) ICSM 350 Amps Operating and Storage Junction Temperature Range Tj Tstg -55 to +175 °C Thermal resistance, junction to lead, discharge, measured at lead adjacent to cover RΘjLD 0.5 °C/W Thermal resistance, junction to lead, charge, measured at lead adjacent to cover RΘjLC 1.0 °C/W Maximum Ratings @ 25°C (unless otherwise specified) Mechanical Outline Datasheet# MSC0945.PDF 2830 S. Fairview St. Santa Ana, CA 92704 PH: (714) 979-8220 FAX: (714) 966-5256 BATTERY CELL BYPASS/SHORTING MODULE

PRELIMINARYDESCRIPTION SYMBOL CONDITIONS MIN TYP. MAX UNIT Forward Voltage, note 1 VD1 IF= 10 A 780 830 mV Forward Voltage, note 1 VD2 IF= 50 A 845 900 mV Forward Voltage, note 1 VD3 IF= 100 A 875 940 mV Forward Voltage, note 1 VD4 IF= 200 A 905 975 mV Forward Voltage, note 1 VD5 IF= 400 A 1100 mV Forward Voltage, note 1 VD6 IF= 200 A, TA= -55°C 985 1070 mV Forward Voltage, note 1 VD7 IF= 200 A, TA= 125°C 790 865 mV note: see MSARS200S200L data sheet for individual characteristics DESCRIPTION SYMBOL CONDITIONS MIN TYP. MAX UNIT Forward Voltage, note 1 VC1 IF= 10 mA - 1.72 - V Forward Voltage, note 1 VC2 IF= 50 mA - 1.9 - V Forward Voltage, note 1 VC3 IF= 100 mA 1.85 2.0 2.1 V Forward Voltage, note 1 VC4 IF= 500 mA - 2.15 - V Forward Voltage, note 1 VC5 IF= 5 A 2.43 2.52 V Forward Voltage, note 1 VC6 IF= 10 A 2.5 2.65 V Forward Voltage, note 1 VC7 IF= 25 A 2.6 2.8 V Forward Voltage, note 1 VC8 IF= 50 A 2.75 2.95 V Forward Voltage, note 1 VC9 IF= 25 A, TA= -55°C 2.9 - V Forward Voltage, note 1 VC10 IF= 25 A, TA= 125°C 2.3 V note: see MSARS50S20Y data sheet for individual characteristics DESCRIPTION SYMBOL CONDITIONS MIN TYP. MAX UNIT Shorted Current Ishort t=dc 400 A Shorted Current (pulse) IPshort t=300ms 1000 A Resistance Rshort End to end of leads 250 300 uΩ Shorted Cycling Cshort Discharge=250A Charge=50A t=2 hrs min 50,000 cycles Shorting Time tshort at full load TBD secs Electrical Parameters, DISCHARGE circuit @ 25°C (unless otherwise specified) Notes (1) Pulse test, t £ 300 ms, duty cycle d £ 2% MM158MSC0945.PDF Electrical Parameters, CHARGE circuit @ 25°C (unless otherwise specified) Electrical Parameters, after cell fails open @ full temperature range