Digits 3 digit + [4 + 4] digit Display No f Keys. o 5 keys (4 user configurable) Input Specifications Digital Input Input Type PNP Input Voltage Range 11 - 28V DC (abs. max.: 30V DC) Response Time Programmable upto 1 to 255ms from Front End (Default 10ms; Also depends on ladder execution time) Isolation 4kV Analog Input No. of Inputs / Type TC / RTD / 0-20mA / 0-10V [User selectable] Sensors J, K, T, R, S, C, E, B, N, L, U, W, PLTNL, RTD, mV (0-60mV), VOLTAGE (0-10V), CURRENT (0-20mA) Resolution 16 bits o Accuracy ForTC inputs: 0.25% of full scale ±1 o For R & S inputs: 0.5% of full scale ±2 (20 min of warm up time for TC inputs) o For RTD inputs: 0.1% of full scale ±1 For V/I Inputs: ± 0.5% of full scale / ± 5 counts whichever greater Conversion time 100 msec Linearity 0.1% Output Specifications Digital Output - Relay Contact Rating NO type : 3A resistive @ 240V AC [For MM1010-24V] 5A resistive @ 240V AC Isolation 4kV Analog Output Output Type Current - 0-20mA Voltage - 0-10V Resolution 14.5 bits Conversion time 20 msec Linearity error 0.1% Programmable Logic ControllerMM101X Features: ! Configurable LED display. ! Windows based software program for configuration. Compact PLC with built-in HMI. Size: 48mm x 96mm Functional Specifications: Programming Method Windows based software for ladder programming and HMI configuration. Memory Data memory: 16 kbytes Code memory: 223 kbytes Max. no. of Objects 5000 (As per memory) Minimum Scan Time 200 µsec Typical Scan Time 1 ms Communication: Communication Ports RS485 port [slave] Communication Protocol MODBUS RTU Relay Outputs Analog Outputs Analog Inputs Digital Inputs Selpro Model Selection IO Configuration Table 5 6 MM1013 MM1013 MM1012 1(0-20mA) MM1012 1(0-10V) MM1012 MM1012-1 MM1012-2 MM1012 MM1010-4 MM1010-1AI (T/R)-DR03 1(V/I) MM1010-V/I MM1010-2 MM1010-T/R MM1010-1 1(TC/RTD) 1(RTD) 2(T/R/V/I) 2(T/R/V/I) 2(T/R/V/I) MM1015 MM1015 1www.selec.com
Programmable Logic ControllerMM101X Environmental Specifications Temperature Humidity (non-condensing) Weight 258gms O Operating : 0 to 50 C O Storage : -20 to 60 C 95% RH Supply Voltage Supply Voltage [As per product selection] Dimensions (in mm) Panel Cutout 97.5 50 46 Terminal Connections MM1010-T/R-24V TC+ /RTD1 TC- /RTD2 I6 I7I3 I4I2 I5 1 2 3 4 5 6 7 8 9 41 1511 12 31 61 71 18 RS485 + RS485 - I0 I1 RTD3 NTC SENSOR For TC/RTD NO4NO1 NO2NO0 NO3 +24VGND COM COMNO1 NO2NO0 1 2 3 4 5 6 7 8 9 14 51 11 21 13 16 17 81 21 32 19 20 TC /RTD1+ RS485 + RS485 - +24V GND NTC SENSOR L(+) N(-) RTD3 TC /RTD2 NO4NO3 For TC/RTD I3I4 I2I5 I1 MM1010-T/R-230V MM1010-V/I-24V I6 I7I3 I4I2 I5I0 I1 1 2 3 4 5 6 7 8 9 41 1511 12 31 61 71 18 RS485 + RS485 - GND NO4NO1 NO2NO0 NO3 ANA IP - ANA IP + +24V COM MM1010-V/I-230V COMNO1 NO2NO0 1 2 3 4 5 6 7 8 9 14 15 11 12 31 61 17 18 21 32 91 20 RS485 + RS485 - +24V GND L(+) N(-) NO4NO3 I3I4 I2I5 I1 ANA IP ANA IP - Terminal Connections MM1010-1AI(T/R)-DR03-230V COMNO1 NO2NO0 1 2 3 4 5 6 7 8 9 41 15 11 12 13 61 71 18 12 32 91 20 RS485 + RS485 - L(+) N(-) RTD1 RTD3 RTD2 +24V GNDCOMNO1 NO2NO0 NO3 I1I2 I0 1 2 3 4 5 6 7 8 9 14 51 11 21 31 61 17 81 21 32 19 20 ANA IP TC /RTD1+ NTC SENSOR RTD3 TC /RTD2 ANA IP - CH2 ANA IP TC /RTD1+ RTD3 TC /RTD2 ANA IP - CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH2 MM1012-24V COMNO1 NO2NO0 NO3 I1I2 I0 1 2 3 4 5 6 7 8 9 14 15 11 12 31 61 17 81 21 23 19 20 ANA IP TC /RTD1+ +24V GND NTC SENSOR L(+) N(-) RTD3 TC /RTD2 ANA IP - CH2 ANA IP TC /RTD1+ RTD3 TC /RTD2 ANA IP - CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH2 MM1012-230V Functional Features Timer Operational Modes On Delay, Off Delay, Pulse, Special [Up/Down] Timer Timer Resolution 1 ms (Accurate only for 1 msec Timer block) Timer Display Format Sec, Min, Hr, Day, Min.Sec, Hr.Min, Day.Hr. Counter Up Counter, Down Counter, Up/Down Counter, Special Up Down Counter Other Blocks PID Control with Autotune, Analog input, Rampsoak, FTC, Analog Output, Hysterisis, Scaling. Memory Retention (4k memory)10 years RTC No 2www.selec.com
Programmable Logic ControllerMM101X Accessories (To be ordered separately) Communication cable ACH-001 (D-Type 9 Pin Cable) PS-CF-24V-1.1A AC-RS485-RS232-01 ( Non Isolated ) AC-RS485-RS232-ISO ( Isolated ) ACD-003 Power Supply Module RS485 to RS232 Windows-based software for ladder programming Converters
Ordering Information
MM1010-1AI(T/R)-DR03-230V MM1012-24V MM1012-230V MM1012-1-24V MM1012-1-230V MM1012-2-24V MM1012-2-230V MM1013-24V MM1013-230V MM1015-230V Order CodeProduct NO4NO1 NO2NO0 NO3 +24V GND NO5 I6I7 I3I4 I2I5 I0I1I8I9 COM 1 2 3 4 5 6 7 8 9 41 15 11 12 31 61 71 18 12 23 91 02 RS485 + RS485 - L(+) N(-) MM1015-230V NO4 COMNO1 NO2NO0 NO3 1 2 3 4 5 6 7 8 9 14 51 11 21 13 16 17 81 21 23 19 20 RS485 + RS485 - +24V GND L(+) N(-) I3I4 I2I5 I0I1 MM1013-230V NO4 COMNO1 NO2NO0 NO3 1 2 3 4 5 6 7 8 9 41 1511 12 13 16 71 18 RS485 + RS485 - +24V I3I4 I2I5 I0I1 GND MM1013-24V +24V GNDCOMNO1 NO2NO0 NO3 I1I2 I0 1 2 3 4 5 6 7 8 9 14 15 11 12 31 61 17 18 21 32 91 20 ANA IP TC /RTD1+ AO + AO - NTC SENSOR RTD3 TC /RTD2 ANA IP - CH2 ANA IP TC /RTD1+ RTD3 TC /RTD2 ANA IP - CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH2 MM1012-1/2-24V Terminal Connections AC-USB-RS485-02 USB to RS485 (with wire) ANA IP TC /RTD1+ NTC SENSOR TC /RTD2 ANA IP - CH2 ANA IP TC /RTD1+ -TC /RTD2 ANA IP - CH1 RTD3 RTD3 COMNO1 NO2NO0 NO3 I1I2 I0 1 2 3 4 5 6 7 8 9 41 15 11 21 13 16 71 18 21 23 91 20 AO + AO - +24V GND L(+) N(-) J1 J2 J3 J4 J5Internal jumper for sensor selection CH1 J1 J2 J3 J4 J5Internal jumper for sensor selection CH2 MM1012-1/2-230V +RS485 RS485 for downloading and networking Reference for analog input type selection For TC/RTD Short J4 & J5 For Volt Short J3 & J4 For Current Short J1 & J2 RS485 on side terminal From Front 3www.selec.com