Features

  • High current capability, easy to parallel to further boost up performance
  • Compact and rugged construction offering weight and space savings
  • Available with PC board solderable pins (see mechanical outline below) or threaded terminals (add “T” suffix to part number, see option below)
  • HPM (Hermetic Power Module)
  • Isolation voltage capability (in reference to the base) in excess of 3kV
  • Very low thermal resistance
  • Thermally matched construction provides excellent temperature and power cycling capability
  • Additional voltage ratings or terminations available upon request
  • MIL-PRF-19500 screening available upon request PART NUMBER SYMBOL MAX. UNIT Discharge Current ID 100 Amps Charge Current IC 20 Amps Non-Repetitive Peak Surge Current (discharge) IDSM 500 Amps Non-Repetitive Peak Surge Current (charge) ICSM 200 Amps Operating and Storage Junction Temperature Range Tj Tstg -55 to +175 °C Thermal resistance, junction to base, discharge RΘjbD 0.7 (typ. 0.5) °C/W Thermal resistance, junction to base , charge RΘjbC 0.9 (typ. 0.75) °C/W Maximum Ratings per leg @ 25°C (unless otherwise specified) Mechanical Outline Datasheet# MSC0322A 2830 S. Fairview St. Santa Ana, CA 92704 PH: (714) 979-8220 FAX: (714) 966-5256 BATTERY BYPASS CIRCUIT

DESCRIPTION SYMBOL CONDITIONS MIN TYP. MAX UNIT Forward Voltage, note 1 VD1 IF= 10 A, 350 340 mV Forward Voltage, note 1 VD2 IF= 20 A, 400 470 mV Forward Voltage, note 1 VD3 IF= 40 A, 490 600 mV Forward Voltage, note 1 VD4 IF= 80 A, 530 800 mV Forward Voltage, note 1 VD5 IF= 100 A, 750 - mV Forward Voltage, note 1 VD6 IF= 20 A, TA= -55°C 490 590 mV Forward Voltage, note 1 VD7 IF= 20 A, TA= 125°C 320 - mV note: see 1N6790 data sheet for full electrical characteristics of the discharge schottky diode DESCRIPTION SYMBOL CONDITIONS MIN TYP. MAX UNIT Forward Voltage, note 1 VC1 IF= 50 mA 2 2.1 - V Forward Voltage, note 1 VC2 IF= 100 mA - 2.2 - V Forward Voltage, note 1 VC3 IF= 5 A, 2.6 2.7 V Forward Voltage, note 1 VC4 IF= 10 A, 2.7 3.0 V Forward Voltage, note 1 VC5 IF= 20 A, 2.85 3.3 V Forward Voltage, note 1 VC4 IF= 10 A, TA= 125°C 2.35 2.7 V Electrical Parameters, DISCHARGE circuit @ 25°C (unless otherwise specified) Notes (1) Pulse test, t £ 300 ms, duty cycle d £ 2% MM054 Electrical Parameters, CHARGE circuit @ 25°C (unless otherwise specified)