+Vo PWM Isolation Ref.Amp LC Filter+Vin -Vin Com. -Vo On/Off OVP Single Output +Vo PWM Isolation Ref.Amp LC Filter+Vin -Vin -Vo On/Off OVP Block Diagram Wide Range 2:1 EN55022 EMI I/O Isolation 1500 VDC More Power High Power Density Remote on/offProtection OVP Minmax's MKW3000 series, comprising 18 different models, has been conceived as an application specific range of DC/DC converters, specially addressing data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. Packing up to 20W of power into a 2x1x0.4 inch package, with efficiency as high as 89%, the MKW3000 has wide input ranges of 9-18VDC, 18-36VDC and 36-75VDC and is available in output voltages of 3.3V, 5V, 12V, 15V, {12V and {15VDC. Other feathers include continuous short circuit protection, overvoltage protection, remote on/off, six-sided shielded case, and EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering. y Over Voltage Protection y Soft Start y Remote On/Off Control y Six-Sided Shielding y Complies with EN55022 Class A y CSA1950 Safety Approval y 2:1 Wide Input Range y MTBF > 800,000 Hours y 1500VDC Isolation y Efficiency up to 89% Key Features 20W, Wide Input Range, Single & Dual Output DC/DC Converters MKW3000 Series REV:0 2005/04MINMAX1
89{18471{40{670{15MKW3047 89{15469{50{835{12MKW3046 891847180134015MKW3044 8915469100167012MKW3043 856.849024040005MKW3042 823.9 2010 33524040003.3 ( 36 ~ 75 ) MKW3041 89{18941{40{670{15MKW3037 89{15938{50{835{12MKW3036 891894180134015MKW3034 8915938100167012MKW3033 856.898024040005MKW3032 823.9 3017 67124040003.3 ( 18 ~ 36 ) MKW3031 88{181903{40{670{15MKW3027 88{151898{50{835{12MKW3026 8818190380134015MKW3024 88151898100167012MKW3023 846.8198424040005MKW3022 813.9 5030 135824040003.3 ( 9 ~ 18 ) MKW3021 % (Typ.)VDCmA (Typ.)mA (Typ.)mA (Typ.)mAmAVDCVDC @Max. Load@No Load@Max. LoadMin.Max. EfficiencyOver Voltage Protection Reflected Ripple Current Input CurrentOutput CurrentOutput Voltage Input Voltage Model Number Model Selection Guide EN55022 Class AConducted EMI Six-Sided Shielded, Metal CaseRFI Free-Air ConvectionCooling %95---Humidity ]+125-50Storage Temperature ]+105-40CaseOperating Temperature ]+50-40AmbientOperating Temperature UnitMax.Min.ConditionsParameter Environmental Specifications Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. mW4,500---Internal Power Dissipation ]260---Lead Temperature (1.5mm from case for 10 Sec.) VDC100-0.748VDC Input Models VDC50-0.724VDC Input Models VDC25-0.712VDC Input Models Input Surge Voltage ( 1000 mS ) UnitMax.Min.Parameter Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. 9. To order the converter without Remote On/Off function, please add a suffix -N (e.g.MKW3021-N). Absolute Maximum Ratings MKW3000 Series 2MINMAXREV:0 2005/04
Reverse Polarity Input Current 34333248V Input Models 1716.51624V Input Models 8.58.38.112V Input ModelsUnder Voltage Shutdown 36353448V Input Models 1817.51724V Input Models VDC 98.88.612V Input ModelsStart Voltage UnitMax.Typ.Min.ModelParameter Input Specifications ContinuousOutput Short Circuit %/]{0.02{0.01---Temperature Coefficient %{4{2---Transient Response Deviation uS300150---25% Load Step ChangeTransient Recovery Time %160---110Over Power Protection mV P-P8055---Ripple & Noise (20MHz) %{0.5{0.1---Io=10% to 100%Load Regulation %{0.3{0.1---Vin=Min. to Max.Line Regulation %{2.0{0.5---Dual Output, Balanced LoadsOutput Voltage Balance %{1.0{0.5---Output Voltage Accuracy UnitMax.Typ.Min.ConditionsParameter Output Specifications KHz360330290Switching Frequency pF15001200---100KHz,1VIsolation Capacitance UnitMax.Typ.Min.ConditionsParameter General Specifications Referenced to Negative InputControl Common mA52---Standby Input Current VDC1---0Supply Off 2.5 to 100VDC or Open CircuitSupply On UnitMax.Typ.Min.ConditionsParameter Remote On/Off Control MKW3000 Series REV:0 2005/04MINMAX3
# For each output uF27027068068068006800Maximum Capacitive Load Unit{15V #{12V #15V12V5V3.3VModels by Vout Capacitive Load 1000mA Slow - Blow Type2000mA Slow - Blow Type4000mA Slow - Blow Type 48V Input Models24V Input Models12V Input Models Input Fuse Selection Guide Vin ( VDC ) 10uS 150 140 130 120 110 100 100uS 1mS 10mS 100mS 48VDC Input Models 24VDC Input Models 12VDC Input Models Input Voltage Transient Rating MKW3000 Series 4MINMAXREV:0 2005/04
]Ambient Temperature Output Power (%) 100 -40 50 60 80 100 110 9070 400LFM 200LFM100LFM Natural convection Efficiency vs Output Load ( Dual Output )Efficiency vs Output Load ( Single Output ) Load Current (%) Efficiency (%) 10060402010 8020 Load Current (%) Efficiency (%) 10060402010 80 Efficiency vs Input Voltage ( Dual Output )Efficiency vs Input Voltage ( Single Output ) 100Efficiency (%) Input Voltage (V) NomLow High50 100Efficiency (%) Input Voltage (V) NomLow High MKW3000 Series REV:0 2005/04MINMAX5
Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance . Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. Peak-to-Peak Output Noise Measurement Test Use a Cout 1.0uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. Design & Feature Considerations Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -0V to 1.0V. A logic high is 2.5V to 100V. The maximum sink current at on/off terminal during a logic low is -100 uA. The maximum allowable leakage current of the switch at on/off terminal (2.5 to 100V) is 5uA. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Overvoltage Protection The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 22uF for the 12V input devices and a 6.8uF for the 24V and 48V devices. MKW3000 Series 6MINMAXREV:0 2005/04 +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7uF capacitors at the output. Maximum Capacitive Load The MKW3000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 270uF maximum capacitive load for dual outputs, 680uF capacitive load for 12V & 15V outputs and 6800uF capacitive load for 3.3V & 5V outputs. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105°C. The derating curves are determined from measurements obtained in an experimental apparatus. MKW3000 Series REV:0 2005/04MINMAX7 +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in
The MKW3000 converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. UL94V-0:Flammability Remote On/OffRemote On/Off6 30g:Weight -Vout-Vout5 CommonNo Pin4 Metal With Non-Conductive Baseplate:Case Material +Vout+Vout3 -Vin-Vin2 2.0*1.0*0.4 inches+Vin+Vin1 50.8*25.4*10.2 mm:Case Size Dual OutputSingle OutputPin Physical CharacteristicsPin Connections {0.002{0.05Pin X.XXX{0.005X.XX{0.13 X.XX{0.01X.X{0.25 InchesMillimetersTolerance Dual Output Single Output 50.8 [2.00] 15.2 [0.60] 10.2 [0.40] Bottom Side 345 5.08 [0.200] 20.30 [0.800] 1.00[ 0.039] Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) Mechanical Dimensions MKW3000 Series 8MINMAXREV:0 2005/04