MKE10-HI MINMAX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

DC/DC CONVERTER 10W, Ultra-high I/O Isolation, 2"×1" Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/08/14 REV:3 Page 1 of 4

FEATURES

► Industrial Standard 2"×1" Package ► Wide 2:1 Input Voltage Range ► Fully Regulated Output Voltage ► Ultra-high I/O Isolation 8000VDC with Reinforced Insulation ► Common Mode Transient Immunity: 15KV/μs ► Qualified for IGBT and High Isolation Applications ► Operating Ambient Temp. Range -40°C to +75°C ► No Min. Load Requirement ► Overload and Short Circuit Protection ► Designed-in Conducted EMI meets EN55022 Class A & FCC Level A ► UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking PRODUCT OVERVIEW The MINMAX MKE10-HI series is a new range of isolated 10W DC/DC converter modules in 2"×1" package which feature a wide input range, fully regulated output and Ultra-high I/O Isolation voltage rated for 8000VDC with reinforced insulation. A very high common mode transient immunity with 15KV/μs qualifies these product for IGBT driver applications. Further features include overload protection, short circuit protection and no min. load requirement as well as EN55022 class A compliant. There are 15 Models available for 12, 24 and 48VDC input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation systems, industrial control equipments and some IGBT driver applications where a very high I/O-isolation is required. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Output Current Input Current Reflected Ripple Current Max. capacitive Load Efficiency (typ.) Max. @Max. Load @No Load @Max. Load VDC VDC mA mA(typ.) mA (typ.) mA(typ.) μF % MKE10-12S05HI (9 ~ 18) 5 1600 889 30 100 1000 75 MKE10-12S051HI 5.1 1600 919 74 MKE10-12S12HI 12 835 1057 470 79 MKE10-12D12HI ±12 ±417 1042 220# 80 MKE10-12D15HI ±15 ±333 1028 81 MKE10-24S05HI (18 ~ 36) 5 2000 548 20 50 1000 76 MKE10-24S051HI 5.1 2000 567 75 MKE10-24S12HI 12 835 522 470 80 MKE10-24D12HI ±12 ±417 516 220# 81 MKE10-24D15HI ±15 ±333 508 82 MKE10-48S05HI (36 ~ 75) 5 2000 274 10 25 1000 76 MKE10-48S051HI 5.1 2000 283 75 MKE10-48S12HI 12 835 261 470 80 MKE10-48D12HI ±12 ±417 258 220# 81 MKE10-48D15HI ±15 ±333 254 82 # For each output Input Specifications Parameter Model Min. Typ. Max. Unit Input Surge Voltage (1 sec. max.) 12V Input Models -0.7 --- 25 VDC 24V Input Models -0.7 --- 50 48V Input Models -0.7 --- 100 Start-Up Threshold Voltage 12V Input Models 7 8 9 24V Input Models 13 15 18 48V Input Models 30 33 36 Under Voltage Shutdown 12V Input Models --- --- 8.5 24V Input Models --- --- 16 48V Input Models --- --- 34 Short Circuit Input Power All Models --- --- 3000 mW Input Filter Internal Pi Type Conducted EMI Compliance to EN 55022,class A and FCC part 15,class A

DC/DC CONVERTER 10W, Ultra-high I/O Isolation, 2"×1" Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/08/14 REV:3 Page 2 of 4 Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy --- --- ±1.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±0.3 ±0.5 % Load Regulation Io=15% to 100% --- ±0.5 ±1.0 % Ripple & Noise 0-20 MHz Bandwidth 5V & 5.1V Output Models --- --- 100 mV P-P Other Output Models --- --- 150 mV P-P Minimum Load No minimum Load Requirement Over Load Protection 120 150 --- % Transient Recovery Time 25% Load Step Change --- 300 600 μsec Transient Response Deviation --- ±3 ±5 % Temperature Coefficient --- ±0.02 ±0.05 %/℃ Short Circuit Protection Continuous, Automatic Recovery Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage Rated for 60 seconds 4000 --- --- VACrms Tested for 1 second 8000 --- --- VDC I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 60 80 pF Common Mode Transient Immunity 15 --- --- KV/μs Safety Approvals UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-report) General Specifications Parameter Conditions Min. Typ. Max. Unit Switching Frequency 120 150 180 KHz MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign 1,000,000 Hours Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +75 ℃ Case Temperature --- +95 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Altitude --- 4000 m Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ Power Derating Curve Ambient Temperature Output Power (%) 100 -40 0 20 60 100 1108040 400LFM Natural Convection 20LFM C

DC/DC CONVERTER 10W, Ultra-high I/O Isolation, 2"×1" Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/08/14 REV:3 Page 3 of 4 Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 We recommend to protect the converter by a slow blow fuse in the input supply line. 4 Other input and output voltage may be available, please contact factory. 5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 6 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout

4 No Pin Common

►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pin diameter  1.0 ±0.05 (0.04±0.002) Physical Characteristics Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 24.5g 10.16 25.4 [1.00] [0.40] 10.16 [0.40] 2.54 [0.10] 5.08 [0.20] Bottom View 45.72 [1.80] 50.8 [2.00] 1.00 [ 0.04] 5 4 5.08 [0.20] 12.0 [0.47]

DC/DC CONVERTER 10W, Ultra--high I/O Isolation, 2"×1" Package 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886 -6-2923149 E -mail: sales@minmax.com.tw 2015/08/14 REV:3 Page 4 of 4 Minmax Technology Co., Ltd. Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0 -20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Technical Notes Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μF for the 12V input devices and a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit. +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Maximum Capacitive Load The MKE10-HI series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from measurements obtained in a test setup. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in