MK150 ASTRODYNE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Compact 150 Watt Enclosed Switching Power Supplies MK150S series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 90-264VAC Auto Ranging Input Compact Footprint High Efficiency Regulated Outputs 4242VDC Isolation Built in EMI Filter Model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ MK150S-5 5 VDC 30 100mv MK150S-12 12 VDC 12.5 100mv MK150S-15 15 VDC 10 100mv MK150S-24 24 VDC 6.25 100mv 3.5”W x 6”L x 1.75”H
Compact 150 Watt Enclosed Switching Power Supplies MK150S series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range 90-132/176-264 VAC 100-120 / 200-240VAC Nominal Frequency Range 47-63 Hz Inrush Current, typ: 20A @ 100VAC * 40A @ 200VAC * Leakage Current <3.5mA @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Line/Load Regulation (NL-FL) ± 0.5%, typ Voltage Tolerance ± 1%, typ DC Voltage Adjust (typ) ± 6%, typ Temperature Coefficient ± 0.03%/°C Ripple/Noise 100mV, typ Over Voltage Protection 130% max. Auto recovery * Over Current Protection 160% max., Auto-recovery * Short Circuit Protection Auto-recovery Hold Up Time 20mS, typ (Nom I/P, FL) Turn On Time ≤ 1.5 sec, typ Rise Time ≤ 250mS, typ Over/Under Shoot < 10% of FS GENERAL SPECIFICATIONS Isolation I/P-O/P: 4242VDC I/P-Ground: 2121VDC O/P-Ground: 707VDC Efficiency 77~80%, typ Switching Frequency 100Khz, (fixed, typical) Safety UL/cUL: UL60950-1 2nd ed./ C22.2 60950-1 2nd ed. UL-EU: EN60950-1 2nd ed. CE: EN60601-1-2 CB: IEC60950-1 2nd ed. ENVIRONMENTAL SPECIFICATIONS Oper. Temperature 0 to +60°C (See Derate Curve) Storage Temperature -25 to +85°C * Relative Humidity 10% to 90%, non-cond * EMI (Designed to Meet) EN55011, Class B MTBF 100,000 Hrs Mil Std 217, 25°C PHYSICAL SPECIFICATIONS Size 6” x 3.5” x 1.75” Construction Enclosed Weight 1.37 lb, (630g) * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted
Compact 150 Watt Enclosed Switching Power Supplies MK150S series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 MECHANICAL DIMENSIONS PLEASE NOTE: To improve specifications and safety isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit Note: For our M3 x 0.5 aluminum threaded holes: Recommended torque: 2.5 in-lbs, 3 in-lbs maximum (2.9 kgf-cm/3.5 kgf-cm max)
Compact 150 Watt Enclosed Switching Power Supplies MK150S series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 OUTPUT DERATING CURVE AAASSSTTTRRROOODDDYYYNNNEEE PPPAAACCCIIIFFFIIICCC CCCOOORRRPPP EEELLLEEECCCTTTRRRIIICCCAAALLL SSSPPPEEECCCIIIFFFIIICCCAAATTTIIIOOONNN 7. Derating Curve Line 2 Line 1 Line 3 20% 40% 60% 80% 100% 120% Load(%) 1. Line 1 : Force air cooling. 2. Line 2 : 12V ,15V & 24V convection cooling. 3. Line 3 : 5V convection cooling. 2915