DC/DC CONVERTER 6W, DIP-Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/31 REV:9 Page 1 of 5
FEATURES
►Industrial Standard DIP-24 Package ►Ultra-wide 4:1 Input Voltage Range ►Fully Regulated Output Voltage ►I/O Isolation 1500 VDC (opt. 3000VDC) ►Operating Ambient Temp. Range -40°C to +85°C ►No Min. Load Requirement ►Overload and Short Circuit Protection ►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MINMAX MIWI06 series is a new range of high performance dc-dc converter modules with 6W output power, featuring ultra-wide 4:1 input voltage ranges and tight output voltage regulation. The product comes in a DIP-24 package with industry standard footprint. Excellent efficiency allows an operation temperature range of -40°C to +85°C . Standard features include overload protection. Typical applications for these cost optimized converters are battery powered equipment, instrumentation, datacom and industrial electronics. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Output Current Input Current Reflected Ripple Current Max. capacitive Load Efficiency (typ.) Max. @Max. Load @No Load @Max. Load VDC VDC mA mA(typ.) mA(typ.) mA(typ.) μF % MIWI06-24S033 (9 ~ 36) 3.3 1200 214 20 20 470 77 MIWI06-24S05 5 1200 313 470 80 MIWI06-24S12 12 500 298 100 84 MIWI06-24S15 15 400 298 100 84 MIWI06-24S24 24 250 298 47 84 MIWI06-24D05 ±5 ±500 260 100# 80 MIWI06-24D12 ±12 ±250 298 100# 84 MIWI06-24D15 ±15 ±200 298 100# 84 MIWI06-48S033 (18 ~ 75) 3.3 1200 107 10 15 470 77 MIWI06-48S05 5 1200 156 470 80 MIWI06-48S12 12 500 149 100 84 MIWI06-48S15 15 400 149 100 84 MIWI06-48S24 24 250 149 47 84 MIWI06-48D05 ±5 ±500 130 100# 80 MIWI06-48D12 ±12 ±250 149 100# 84 MIWI06-48D15 ±15 ±200 149 100# 84 # For each output Input Specifications Parameter Model Min. Typ. Max. Unit Input Surge Voltage (1 sec. max.) 24V Input Models -0.7 --- 50 VDC 48V Input Models -0.7 --- 100 Start-Up Threshold Voltage 24V Input Models 7 8 9 48V Input Models 14 16 18 Under Voltage Shutdown 24V Input Models --- --- 8.5 48V Input Models --- --- 16 Short Circuit Input Power All Models --- --- 3000 mW Input Filter Internal Pi Type Conducted EMI Compliance to EN 55022,class A and FCC part 15,class A
DC/DC CONVERTER 6W, DIP-Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/31 REV:9 Page 2 of 5 Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy --- --- ±2.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±1.0 ±2.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±0.1 ±0.5 % Load Regulation Io=0% to 100% --- ±0.6 ±1.2 % Minimum Load No minimum Load Requirement Ripple & Noise 0-20 MHz Bandwidth --- --- 80 mV P-P Transient Recovery Time 25% Load Step Change --- 300 600 μsec Transient Response Deviation --- ±3 ±5 % Temperature Coefficient --- ±0.01 ±0.02 %/℃ Over Load Protection Foldback 110 150 --- % Short Circuit Protection Continuous, Automatic Recovery General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage 60 Seconds Standard 1500 --- --- VDC Suffix H 3000 --- --- VDC
1 Second Standard 1800 --- --- VDC
I/O Isolation Resistance 500 VDC 1000 --- --- MΩ I/O Isolation Capacitance 100KHz, 1V --- 1000 --- pF Switching Frequency --- 330 --- KHz MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign 800,000 Hours Safety Approvals UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report) Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +85 ℃ Case Temperature --- +100 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ Power Derating Curve Ambient Temperature Output Power (%) 100 -40 0 20 60 100 1108040 Natural Convection 20LFM 400LFM 200LFM 100LFM C Ambient Temperature Output Power (%) 100 -40 0 20 60 100 1108040 Natural Convection 20LFM 400LFM 200LFM 100LFM C (3.3 & 5V Output Models) (Other Output Models)
DC/DC CONVERTER 6W, DIP-Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/31 REV:9 Page 3 of 5 Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100% 3 We recommend to protect the converter by a slow blow fuse in the input supply line. 4 Other input and output voltage may be available, please contact factory. 5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 6 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 2 -Vin -Vin 3 -Vin -Vin
9 No Pin Common
11 NC -Vout
NC: No Connection ►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pin diameter 0.5 ±0.05 (0.02±0.002) Physical Characteristics Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 12.7g Bottom View 2 11 141623 15.24 [0.60] 5.08 [0.20] 4.1 [0.16] 3 9 4.5 [0.18] 10.2 [0.40] 15.22 [0.60] 20.3 [0.80] 2.54 [0.10] 31.8 [1.25] 2.54 [0.10] 0.50 [0.02]
DC/DC CONVERTER 6W, DIP-Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/31 REV:9 Page 4 of 5 Order Code Table Standard 3KVDC isolation MIWI06-24S033 MIWI06-24S033H MIWI06-24S05 MIWI06-24S05H MIWI06-24S12 MIWI06-24S12H MIWI06-24S15 MIWI06-24S15H MIWI06-24S24 MIWI06-24S24H MIWI06-24D05 MIWI06-24D05H MIWI06-24D12 MIWI06-24D12H MIWI06-24D15 MIWI06-24D15H MIWI06-48S033 MIWI06-48S033H MIWI06-48S05 MIWI06-48S05H MIWI06-48S12 MIWI06-48S12H MIWI06-48S15 MIWI06-48S15H MIWI06-48S24 MIWI06-48S24H MIWI06-48D05 MIWI06-48D05H MIWI06-48D12 MIWI06-48D12H MIWI06-48D15 MIWI06-48D15H
DC/DC CONVERTER 6W, DIP-Package 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886 -6-2923149 E -mail: sales@minmax.com.tw 2015/07/31 REV:9 Page 5 of 5 Minmax Technology Co., Ltd. Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Technical Notes Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0 Ω at 100 KHz) capacitor of a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices. +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Maximum Capacitive Load The MIWI06 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from measurements obtained in a test setup. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in