FEATURES
►DIP-24 Plastic Package ►Wide 2:1 Input Range ►High Efficiency up to 86% ►Operating Temp. Range –40°C to +85°C ►Short Circuit Protection ►I/O-isolation 1500VDC ►Cost optimized Design ►3 Years Product Warranty PRODUCT OVERVIEW The MIW3100 series is a range of isolated 6W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage ranges. The product comes in a DIP-24 plastic package with industry standard pinout. An excellent efficiency allows an operating temperature range of –40°C to +85°C.These DC/DC converters offer an economical solution for many cost critical applications in battery-powered equipment and instrumentation. Model Selection Guide Output Current Input Current Efficiency (typ.) Input Voltage (Range) Output Voltage Max. Min. @Max. Load @No Load Reflected Ripple Current Max. capacitive Load @Max. Load Model Number VDC VDC mA mA mA(typ.) mA(typ.) mA(typ.) uF % MIW3121 3.3 1200 60 429 77 MIW3122 5 1000 50 514 81 MIW3123 12 500 25 595 6800 MIW3126 ±12 ±250 ±12.5 595 84 MIW3127 (9 ~ 18) ±15 ±200 ±10 595 20 25 1000# 84 MIW3131 3.3 1200 60 209 79 MIW3132 5 1000 50 251 83 MIW3133 12 500 25 291 6800 MIW3136 ±12 ±250 ±12.5 291 86 MIW3137 (18 ~ 36) ±15 ±200 ±10 291 5 15 1000# 86 # For each output Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models -0.7 --- 25 Input Surge Voltage (1 sec. max.) 24V Input Models -0.7 --- 50 12V Input Models 4.5 6 8Start-Up Voltage 24V Input Models 8 12 16 12V Input Models --- --- 8Under Voltage Shutdown 24V Input Models --- --- 16 VDC Reverse Polarity Input Current --- --- 1 A Short Circuit Input Power --- 1000 3000 mW Internal Power Dissipation --- --- 2500 mW Conducted EMI (with suffix A only) All Models Compliance to EN 55022,class A and FCC part 15,class A Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com
DC/DC CONVERTER 6W, DIP-Package Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Accuracy --- ±0.5 ±1.0 % Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. --- ±0.1 ±0.3 % Load Regulation Io=20% to 100% --- ±0.3 ±1.0 % Ripple & Noise (20MHz) --- 50 75 mV P-P Ripple & Noise (20MHz) Over Line, Load & Temp. --- --- 100 mV P-P Ripple & Noise (20MHz) --- --- 15 mV rms Transient Recovery Time --- 150 300 uS Transient Response Deviation 25% Load Step Change --- ±2 ±6 % Temperature Coefficient --- ±0.01 ±0.02 %/℃ Over Load Protection Foldback 120 150 --- % Short Circuit Protection Cont inuous General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage (rated) 60 Seconds 1500 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- M Ω I/O Isolation Capacitance 100KHz, 1V --- 380 500 pF Switching Frequency --- 300 --- KHz MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign 1,000,000 --- --- Hours Safety Approvals UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme) Input Fuse 12V Input Models 24V Input Models 1500mA Slow-Blow Type 700mA Slow-Blow Type Environmental Specifications Parameter Conditions Min. Max. Unit Operating Temperature Range (with Derating) Ambient -40 +85 ℃ Case Temperature --- +90 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ Power Derating Curve ]Ambient Temperature 100 -40 0 20 60 100 1108040 400LFM 200LFM 100LFM Natural convection Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Tota Total Power International, Inc.
DC/DC CONVERTER 6W, DIP-Package Notes 1 Specifications typical at Ta=+25 ℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100% 3 Ripple & Noise measurement bandwidth is 0-20MHz. 4 These power converters require a minimu m output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 5 All DC/DC converters should be externally fused at the front end for protection. 6 Other input and output voltage may be av ailable, please contact factory. 7 To order the converter with input filter meeting EN55022, Class A , add suffix A (e.g. MIW3121A) to order code. 8 Specifications subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 2 -Vin -Vin 3 -Vin -Vin
9 No Pin Common
11 NC -Vout
NC: No Connection ►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pin diameter 0.5 ±0.05 (0.02±0.002) Physical Characteristics Case Material : Non-Conductive Black Pl astic (flammability to UL 94V-0 rated) Weight : 16. 9g Bottom View 2 11 141623 15.24 [0.60] 5.08 [0.20] 4.1 [0.16] 3 9 4.5 [0.18] 10.2 [0.40] 15.22 [0.60] 20.3 [0.80] 2.54 [0.10]31.8 [1.25] 2.54 [0.10] 0.50 [0.02] Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Tota Total Power International, Inc.
DC/DC CONVERTER 6W, DIP-Package Test Configurations Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Design & Feature Considerations Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 3.3uF for the 12V input devices and a 2.2uF for the 24V devices. +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Maximum Capacitive Load MIW3100 series have limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 1000uF maximum capacitive load for dual outputs and 6800uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Tota Total Power International, Inc.