MIW1000 MINMAX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

+Vo PFM Isolation Ref.Amp LC Filter+Vin -Vin Com. -Vo Single Output PFM Isolation Ref.Amp LC Filter+Vin -Vin -Vo +Vo Block Diagram Wide Range 2:1 I/O Isolation 1500 VDC Low Cost Minmax's MIW1000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 4.5-9VDC, 9-18VDC, 18-36VDC and 36-72VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC. The -40] to +71] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. The modules have a maximum power rating of 3W and a typical full-load efficiency of 84%, continuous short circuit, 45mV output ripple, built-in filtering for both input and output minimize the need for external filtering. y Interanl SMD Construction y UL 94V-0 Package Material y Industry Standard Pinout y Temperature Performance -40] to +71] y Low Cost y UL1950 Safety Approval y 2:1 Wide Input Range y MTBF > 1,000,000 Hours y 1500VDC Isolation y Efficiency up to 84% Key Features 2-3W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MIW1000 Series REV:0 2005/04MINMAX1

8475{10{100{15MIW1047 8475{12.5{125{12MIW1046 8065{25{250{5MIW1045 84752020015MIW1044 84752525012MIW1043 7966505005MIW1042 103 55606003.3 ( 36 ~ 72 ) MIW1041 82152{10{100{15MIW1037 82152{12.5{125{12MIW1036 79132{25{250{5MIW1035 841492020015MIW1034 841492525012MIW1033 79132505005MIW1032 155 109606003.3 ( 18 ~ 36 ) MIW1031 80313{10{100{15MIW1027 80313{12.5{125{12MIW1026 77271{25{250{5MIW1025 823052020015MIW1024 823052525012MIW1023 78267505005MIW1022 3020 223606003.3 ( 9 ~ 18 ) MIW1021 75800{10{100{15MIW1017 75800{12.5{125{12MIW1016 72694{25{250{5MIW1015 777792020015MIW1014 777792525012MIW1013 73685505005MIW1012 10040 566606003.3 ( 4.5 ~ 9 ) MIW1011 % (Typ.)mA (Typ.)mA (Typ.)mA (Typ.)mAmAVDCVDC @Max. Load@No Load@Max. LoadMin.Max. EfficiencyReflected Ripple Current Input CurrentOutput CurrentOutput Voltage Input Voltage Model Number Model Selection Guide Free-Air ConvectionCooling %95---Humidity ]+125-40Storage Temperature ]+90-40CaseOperating Temperature ]+71-40AmbientOperating Temperature UnitMax.Min.ConditionsParameter Environmental Specifications Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. mW2,500---Internal Power Dissipation ]260---Lead Temperature (1.5mm from case for 10 Sec.) VDC100-0.748VDC Input Models VDC50-0.724VDC Input Models VDC25-0.712VDC Input Models VDC11-0.75VDC Input Models Input Surge Voltage ( 1000 mS ) UnitMax.Min.Parameter Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. Absolute Maximum Ratings MIW1000 Series 2MINMAXREV:0 2005/04

KHz---300---Switching Frequency pF10065---100KHz,1VIsolation Capacitance UnitMax.Typ.Min.ConditionsParameter General Specifications ContinuousOutput Short Circuit %/]{0.02{0.01---Temperature Coefficient %{5{3---Transient Response Deviation uS500300---50% Load Step ChangeTransient Recovery Time mV P-P6045---Ripple & Noise (20MHz) %{0.5{0.2---Io=10% to 100%Load Regulation %{0.5{0.2---Vin=Min. to Max.Line Regulation %{2.0{0.5---Dual Output, Balanced LoadsOutput Voltage Balance %{1.0{0.5---Output Voltage Accuracy UnitMax.Typ.Min.ConditionsParameter Output Specifications Pi FilterInput Filter mW20001000---Short Circuit Input Power All Models Reverse Polarity Input Current 3422---48V Input Models 1711---24V Input Models 8.56.5---12V Input Models 43.5---5V Input ModelsUnder Voltage Shutdown 36241648V Input Models 1812824V Input Models 974.512V Input Models VDC 4.543.55V Input ModelsStart Voltage UnitMax.Typ.Min.ModelParameter Input Specifications # For each output uF1000100010004000400040004000Maximum Capacitive Load Unit{15V #{12V #{5V #15V12V5V3.3VModels by Vout Capacitive Load MIW1000 Series REV:0 2005/04MINMAX3

135mA Slow - Blow Type350mA Slow - Blow Type700mA Slow - Blow Type1500mA Slow - Blow Type 48V Input Models24V Input Models12V Input Models5V Input Models Input Fuse Selection Guide Vin ( VDC ) 10uS 150 140 130 120 110 100 100uS 1mS 10mS 100mS 48VDC Input Models 24VDC Input Models 12VDC Input Models 5VDC Input Models Input Voltage Transient Rating MIW1000 Series 4MINMAXREV:0 2005/04

]Ambient Temperature Output Power (%) 100 -40 50 60 80 100 110 9070 400LFM 200LFM 100LFM Natural convection Efficiency vs Output Load ( Dual Output )Efficiency vs Output Load ( Single Output ) Load Current (%) Efficiency (%) 10060402010 8020 Load Current (%) Efficiency (%) 10060402010 80 Efficiency vs Input Voltage ( Dual Output )Efficiency vs Input Voltage ( Single Output ) 100Efficiency (%) Input Voltage (V) NomLow High Input Voltage (V) 100Efficiency (%) NomLow High MIW1000 Series REV:0 2005/04MINMAX5

Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. Design & Feature Considerations Maximum Capacitive Load The MIW1000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 1000uF maximum capacitive load for dual outputs and 4000uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 8.2uF for the 5V input devices, a 3.3uF for the 12V input devices and a 1.5uF for the 24V and 48V devices. Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. MIW1000 Series 6MINMAXREV:0 2005/04 +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter

Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90°C. The derating curves are determined from measurements obtained in an experimental apparatus. MIW1000 Series REV:0 2005/04MINMAX7 DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in

The MIW1000 converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. NC: No Connection +Vin+Vin23 UL94V-0:Flammability+Vin+Vin22 Common-Vout16 12g:Weight +Vout+Vout14 -VoutNC11 Non-Conductive Black Plastic:Case Material CommonNo Pin9 -Vin-Vin3 1.25*0.80*0.40 inches-Vin-Vin2 31.8*20.3*10.2 mm:Case Size Dual OutputSingle OutputPin Physical CharacteristicsPin Connections {0.002{0.05Pin X.XXX{0.005X.XX{0.13 X.XX{0.01X.X{0.25 InchesMillimetersTolerance Dual Output Single Output 31.8 [1.25] 10.2 [0.40] 20.3 [0.80] Bottom 4.5 [0.18] Side 23 9 1 1 16 1423 22 3.8 [0.15] 0.5 [0.020] 2.54 [0.100] 15.22 [0.600] 2.5 [0.10] Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) Mechanical Dimensions MIW1000 Series 8MINMAXREV:0 2005/04