MIP HONEYWELL | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 8
Technical content
DESCRIPTION
The MIP Series offers a heavy duty, media-isolated pressure transducer in a compact, stainless steel construction for use with a wide range of media including aggressive fluids and water. The MIP Series provides a cost-competitive solution for wide-ranging potential applications in tough environments. VALUE TO CUSTOMERS
- Total Error Band (TEB) ±0.75 %FSS (Full Scale Span) from -40°C to 125°C for ratiometric output: Provides true measurement performance over the compensated temperature range; small error promotes system uptime and efficiency (see Figure 4).
- 4 mA to 20 mA output: Supports transmission of output signals over longer distances
- EMC performance: Operates reliably in the presence of electromagnetic fields, such as wireless signals, RF communication, and electrical devices.
- Hermetically welded design: Supports almost any media without the use of an internal seal. The sensors are designed to be used in harsh environments which see aggressive media. DIFFERENTIATION
- Diagnostics: Beneficial in applications where the sensor functionality and the need to know internal or external failure modes is critical.
- Great customer value: Multiple configuration possibilities provide flexibility of use in the application with no up front NRE or tooling charges.
- Durable: Provides the tough environmental capabilities needed, including long-term stability, insulation resistance and dielectric strength, external freeze-thaw resistance for the Metri-Pack 150 versions and EMC performance. 32354483 Issue C
TABLE 1. POTENTIAL APPLICATIONS
FEATURES
- Rugged, stainless steel construction
- Ratiometric output: 0.5 Vdc to 4.5 Vdc
- Current output: 4 mA to 20 mA
- Operating temperature: -40°C to 125°C
- Total Error Band: ±0.75 %FSS to ±1.0 %FSS (-40°C to 125°C) for voltage output
- Industry-leading accuracy: ±0.15 %FSS BFSL for voltage output
- Long term stability: ±0.25 %FSS
- Radiated immunity: 100 V/m
- Drinking water approval: NSF/ANSI/CAN 61
- CE, UKCA, RoHS, REACH compliant
- Mis-wiring protection Certified to NSF/ANSI/CAN 61 MIP SERIES Heavy Duty, Media-Isolated Pressure Transducers 1 bar to 60 bar | 15 psi to 870 psi PORTFOLIO Honeywell offers a variety of heavy duty pressure transducers for potential use in industrial and transportation applications. To view the entire product portfolio, click here.
TABLE 3. PERFORMANCE SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.)
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
3 V (150 kHz to 80 MHz) per IEC 61000-4-6
100 V/m (100 kHz to 400 MHz) per ISO 11452-5
1 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. thermal effect on span, and thermal hysteresis (see Figure 5). 2 TEB: Above 100°C [212°F] for pressure ratings less than 4 bar [58 psi], TEB is ±1.5 %FSS for ratiometric outputs and 2.0 % FSS for other outputs. [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. 5 Startup time: The time needed to receive valid output after power up. TABLE 2. ELECTRICAL SPECIFICATIONS (AT 25°C [77°F] AND UNDER UNLESS OTHERWISE NOTED.) 1 Supply voltage: Must be de-rated to 8 Vdc to 25 Vdc for above 100°C to 125°C [212°F to 257°F]. 2 Applies at 25°C [77°F]. See Figure 4 for Current Output Supply Voltage. TABLE 4. ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS AWM-I-A/B-II-A/B specification, -40°C to 125°C [-40°F to 257°F], three 24 AWG wires.
FIGURE 1. NOMENCLATURE AND ORDER GUIDE 1 Contact Honeywell Sales for custom configurations. 2 See Table 4 for cable material specifications. 3 Other external seal materials are available for G1, G2, and M1 Pressure port types. 4 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.
- Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.)
- Use appropriate tools (such as an open-ended wrench or deep well socket) to install transducers.
- Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits.
- Ensure that filters are used upstream of the transducers to keep media flow free of particulates. MIP Series transducers are dead-end devices. Particulate accumulation may clog the port or damage the diaphragm.
- Ensure that the transducer is mounted in a vertical position with the process connection (pressure port) downward to avoid particular deposits.
- Ensure that the media does not create a residue when dried. Build-up of residue inside the transducer may affect transducer output.
- Ensure that the transducer housing is properly grounded.
- For cable harness versions, ensure that the cable bend radius is maintained at a minimum of 38 mm [1.50 in] in the end application assembly. Failure to comply with these instructions may result in product damage.
FIGURE 3. ABSOLUTE VS SEALED GAGE Example shown is for 100 psi. FIGURE 2. RATIOMETRIC OUTPUT TRANSFER FUNCTION 90 % Vsupply at full scale pressure. TABLE 5. PRESSURE RATINGS is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. be expected to function after exposure to the burst pressure. FIGURE 4. CURRENT OUTPUT SUPPLY VOLTAGE VS TEMPERATURE
10 Ohm
100 Ohm
250 Ohm
TABLE 6. OUTPUT DIAGNOSTIC CODE FOR RATIOMETRIC OUTPUT maximum error that the sensor could experience. the most comprehensive measurement of a sensor’s true accuracy. does not use the TEB specification. FIGURE 5. TEB COMPONENTS FOR THE MIP SERIES would be TEB) could be significant.
FIGURE 6. METRI-PACK 150 MOUNTING DIMENSIONS (FOR REFERENCE ONLY. MM/[IN])
FIGURE 7. CABLE HARNESS MOUNTING DIMENSIONS (FOR REFERENCE ONLY. MM/[IN])
32354483-C-EN | C | 09/21 © 2021 Honeywell International Inc. All rights reserved. Honeywell Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081 sps.honeywell.com/ast WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. ADDITIONAL MATERIALS The following associated literature is available on our website:
- Product range guide
- Application-specific and technical information
- CAD Models FOR MORE INFORMATION Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call: USA/Canada +1 302 613 4491 Latin America +1 305 805 8188 Europe +44 1344 238258 Japan +81 (0) 3-6730-7152 Singapore +65 6355 2828 Greater China +86 4006396841