DC/DC CONVERTER 3W, Ultra-high I/O lsolation, DIP Package E-mail:sales@minmax.com.tw Tel:886-6-2923150 2015/07/22 P3 Page 1 of 4

FEATURES

►Industrial Standard DIP-24 Package ►Wide 2 :1 Input Voltage Range ►Fully Regulated Output Voltage ►Ultra-high I/O Isolation 8000VDC ►Common Mode Transient Immunity: 15KV/μs ►Qualified for IGBT and High Isolation Applications ►Operating Temp. Range -40°C to +85°C ►Overload and Short Circuit Protection ►Conducted EMI meets EN55022 Class A & FCC Level A ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MINMAX MIE03-HI series is a new range of isolated 3W DC/DC converter modules in DIP-24 package which feature a wide input range, fully regulated output and Ultra-high I/O Isolation voltage rated for 8000VDC with reinforced insulation. A very high common mode transient immunity with 15KV/μs qualifies these product for IGBT driver applications. Further features include over load protection, short circuit protection and EN55022 class A compliant as well. There are 20 Models available for 5, 12, 24 and 48VDC input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation systems, industrial control equipments and some IGBT driver applications where a very high I/O-isolation is required. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Output Current Input Current Reflected Ripple Current Max. capacitive Load Efficiency (typ.) Max. Min. @Max. Load @No Load @Max. Load VDC VDC mA mA mA(typ.) mA(typ.) mA (typ.) μF % MIE03-05S05HI (4.5 ~ 9) 5 600 90 870 40 60 1000 69 MIE03-05S12HI 12 250 37.5 811 470 74 MIE03-05S24HI 24 125 18.8 800 470 76 MIE03-05D12HI ±12 ±125 ±18.8 800 220# 75 MIE03-05D15HI ±15 ±100 ±15 800 220# 75 MIE03-12S05HI (9 ~ 18) 5 600 90 342 30 30 1000 73 MIE03-12S12HI 12 250 37.5 316 470 79 MIE03-12S24HI 24 125 18.8 313 470 81 MIE03-12D12HI ±12 ±125 ±18.8 313 220# 80 MIE03-12D15HI ±15 ±100 ±15 313 220# 80 MIE03-24S05HI (18 ~ 36) 5 600 90 162 20 15 1000 77 MIE03-24S12HI 12 250 37.5 152 470 82 MIE03-24S24HI 24 125 18.8 151 470 84 MIE03-24D12HI ±12 ±125 ±18.8 151 220# 83 MIE03-24D15HI ±15 ±100 ±15 151 220# 83 MIE03-48S05HI (36 ~ 75) 5 600 90 81 10 10 1000 77 MIE03-48S12HI 12 250 37.5 76 470 82 MIE03-48S24HI 24 125 18.8 75 470 84 MIE03-48D12HI ±12 ±125 ±18.8 75 220# 83 MIE03-48D15HI ±15 ±100 ±15 75 220# 83 # For each output

DC/DC CONVERTER 3W, Ultra-high I/O lsolation, DIP Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/22 P3 Page 2 of 4 Input Specifications Parameter Model Min. Typ. Max. Unit Input Surge Voltage (1 sec. max.) 5V Input Models -0.7 --- 11 VDC 12V Input Models -0.7 --- 25 24V Input Models -0.7 --- 50 48V Input Models -0.7 --- 100 Start-Up Threshold Voltage 5V Input Models 3.7 4 4.5 12V Input Models 8 8.5 9 24V Input Models 15 17 18 48V Input Models 30 33 36 Under Voltage Shutdown 5V Input Models --- --- 4 12V Input Models --- --- 8.5 24V Input Models --- --- 17 48V Input Models --- --- 34 Short Circuit Input Power All Models --- --- 2000 mW Conducted EMI Compliance to EN 55022,class A and FCC part 15,class A Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy --- --- ±1.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±0.3 ±0.5 % Load Regulation Io=25% to 100% --- ±0.5 ±1.0 % Ripple & Noise 0-20 MHz Bandwidth 5V Output Models --- 75 100 mV P-P Other Output Models --- 100 150 mV P-P Transient Recovery Time 25% Load Step Change --- 150 500 μsec Transient Response Deviation --- ±3 ±6 % Temperature Coefficient --- ±0.02 ±0.05 %/℃ Over Load Protection Foldback 120 150 --- % Short Circuit Protection Continuous Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage Rated for 60 seconds 4000 --- --- VACrms Tested for 1 second 8000 --- --- VDC I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 7 13 pF Common Mode Transient Immunity 15 --- --- KV/μs Safety Approvals UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-report) General Specifications Parameter Conditions Min. Typ. Max. Unit Switching Frequency --- 150 --- KHz MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign 1,000,000 Hours Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +85 ℃ Case Temperature --- +100 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃

DC/DC CONVERTER 3W, Ultra-high I/O lsolation, DIP Package E-mail:sales@minmax.com.tw Tel:886 -6-2923150 2015/07/22 P3 Page 3 of 4 Power Derating Curve Ambient Temperature Output Power (%) 100 -40 0 20 60 100 1108040 400LFM 200LFM 100LFM Natural Convection 20LFM C Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4 We recommend to protect the converter by a slow blow fuse in the input supply line. 5 Other input and output voltage may be available, please contact factory. 6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 7 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 1 +Vin +Vin

11 No Pin Common

15 No Pin +Vout

►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) Physical Characteristics Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 16.2g Bottom View 131524 20.32 [0.80] 15.22 [0.60] 20.3 [0.80] 10.5 [0.41] 5.08 [0.20] 3.9 [0.15] 0.2 [0.008] 2.0 [0.08] 2.54 [0.10] 0.60 [0.024] 2.54 [0.10] 31.8 [1.25]

DC/DC CONVERTER 3W, Ultra-high I/O lsolation, DIP Package 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886 -6-2923149 E -mail: sales@minmax.com.tw 2015/07/22 P3 Page 4 of 4 Minmax Technology Co., Ltd. Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Technical Notes Overload Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μF for the 5V input devices and a 4.7μF for the 12V input devices and 2.2μF for the 24V and 48V devices. +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Maximum Capacitive Load The MIE03-HI series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from measurements obtained in a test setup.