THE REVISION STATUS OF ALL SHEETS OF THIS DRAWING IS THE SAME AS SHEET 1 Unless otherwise spec- ified, dimensions are in MM. Tolerances are applicable when spec- ified. These drawings and specifications contain proprietary information which is the property of Times Microwave Systems. MG160 CABLE ASSEMBLY (Space Assemblies) Size A CAGE CODE 68999 Drawing No.: IE-00408-XX Scale: NA Rev. (A) Sheet: 1 of 3 Approvals Drawn Checked Approved YA 10/20/22 TIMES MICROWAVE SYSTEMS www.timesmicrowave.com REV DESCRIPTION DATE BY A INITIAL RELEASE 10/20/22 YA Dwg. Number Customer P/N Times P/N Length(L) in ‘mm’ IE-00408-01 - MGS160-SMSM-0.5M 500 +10/-0 IE-00408-02 - MGS160-SMSM-1.0M 1000 +20/-0 IE-00408-03 - MGS160-SMSM-1.5M 1500 +30/-0 IE-00408-04 - MGS160-SMSM-2.0M 2000 +40/-0

1.0 Scope

This drawing documents the construction and performance of Maxgain 160 cable assemblies manufactured by Times Microwave systems.

2.0 Cable Information

2.1 Cable to be MAXGAIN 160

2.2 Jacket color to be Blue

2.3 Jacket material to be FEP

2.4 Nominal cable impedance to be 50 ohms

2.5 Cable diameter to be 4.04mm [0.159”] (Nominal).

3.0 Connector Information

3.1 Forward Connector

Type SMA (M) Straight Connector (SP007) Connector Body – Stainless Steel, Gold Plated Center Contact – Beryllium Copper, Gold Plated

3.2 After Connector

Type SMA (M) Straight Connector (SP007) Connector Body – Stainless Steel, Gold Plated Center Contact – Beryllium Copper, Gold Plated

THE REVISION STATUS OF ALL SHEETS OF THIS DRAWING IS THE SAME AS SHEET 1 Unless otherwise spec- ified, dimensions are in MM. Tolerances are applicable when spec- ified. These drawings and specifications contain proprietary information which is the property of Times Microwave Systems. MG160 CABLE ASSEMBLY (Space Assemblies) Size A CAGE CODE 68999 Drawing No.: IE-00408-XX Scale: NA Rev. (A) Sheet: 2 of 3 Approvals Drawn Checked Approved YA 10/20/22 TIMES MICROWAVE SYSTEMS www.timesmicrowave.com REV DESCRIPTION DATE BY A INITIAL RELEASE 10/20/22 YA

4.0 Electrical Performance

4.1 Frequency range: DC – 22GHz

4.2 Insertion loss & VSWR: As per below table,

5.0 Mechanical Performance

5.1 Overall Length to be specified length. 5.2 Minimum Bend radius is 19mm [0.750”].

6.0 Environmental Performance

6.1 Installation Temperature Range (-55°C to +150°C)

6.2 Storage Temperature Range (-55°C to +150°C)

6.3 Operating Temperature Range (-55°C to +150°C)

7.0 Marking

7.1 Markers are to be black text on White Color Marker Sleeve.

7.2 Marker Configuration to be:

7.3 $$$$$ = 5-digit Serial Number for this specific configuration. 7.4 Register to be Maintained for Serial Number. Dwg. Number Max. Insertion Loss in dB Max. VSWR @ 22GHz @ 22GHz IE-00408-01 1.43 1.35 IE-00408-02 2.53 1.35 IE-00408-03 3.52 1.35 IE-00408-04 4.51 1.35 Dwg. Number Marking details Marker Numbers Marker Position IE-00408-01 Times Microwave Systems MGS160-SMSM-0.5M

1 In center of the

cable assy. IE-00408-02 Times Microwave Systems MGS160-SMSM-1.0M cable assy. IE-00408-03 Times Microwave Systems MGS160-SMSM-1.5M 1 & 2 At both ends. IE-00408-04 Times Microwave Systems MGS160-SMSM-2.0M 1 & 2 At both ends.

THE REVISION STATUS OF ALL SHEETS OF THIS DRAWING IS THE SAME AS SHEET 1 Unless otherwise spec- ified, dimensions are in MM. Tolerances are applicable when spec- ified. These drawings and specifications contain proprietary information which is the property of Times Microwave Systems. MG160 CABLE ASSEMBLY (Space Assemblies) Size A CAGE CODE 68999 Drawing No.: IE-00408-XX Scale: NA Rev. (A) Sheet: 3 of 3 Approvals Drawn Checked Approved YA 10/20/22 TIMES MICROWAVE SYSTEMS www.timesmicrowave.com REV DESCRIPTION DATE BY A INITIAL RELEASE 10/20/22 YA

8.0 NOTES

8.1 All Dimensions are in MM. 8.2 Assemblies built in Class 100,000 clean room. 8.3 Low outgassing materials per ASTM E595.

8.4 Unless Otherwise Specified: Tolerance will be,

Linear Dimension Tolerance <500 mm ±10 mm 500-2000 mm ±15 mm >2000 mm ±20 mm **Tolerances are not accumulative.