standexelectronics.comDatasheet Rev DDB Page 1 +1 970.879.9900 | sensorsales@standexelectronics.com MFM7-275VPD-RGCD4 Digital Ferrous Metal Detection Sensor Ferrous Metal Hall Proximity Sensor .375” detection gap Regulated input, 0-5V output Plastic .7” flange mount 1.5” long housing Deutsch DT04 4 pin with 5” 20 AWG XLPE Part Description: MFM 7 - 275 VPD - RGCD 3 Housing Sensor Type & Function Electrical Option Connection Type Glass Filled Nylon Flange Mount ø.7“ x 1.5“ Digital Ferrous Metal Proximity Sensor Regulated Input 0-5V Digital Output Deutsch DT 4 pin w/5” 20AWG XLPE ‘Digital Output switches on when Ferrous Metal is present’
DESCRIPTION
- Digital output turns on when ferrous metal is detected
- Programmed to detect a large steel target at 0.375”
- Target detection gap is dependent on shape/size/ferrous content.
- Custom programming available for precision repeatable detection of targets, contact Sensor Solutions.
- Flange mount installation sets fixed gap from target.
FEATURES
- True Zero Speed
- Large Detection Gap
- Internal Hysteresis
- Detects Through Aluminum CUSTOMER FOCUSED ENGINEERING + MODULAR DESIGN HOUSING - Aluminum, stainless steel, plastic, threaded, flange mount, customer specific ELECTRICAL - Every sensor function available in various electrical options (NPN, PNP, TTL, etc.) CONNECTION - Deutsch, Amphenol, many other brands, free end wires, pigtails, any length Need a Custom Sensor Solution?... Send us your application specific requirements at sensorso.com Modify, update, or enhance any sensor with our modular features and functionality.
standexelectronics.comDatasheet Rev DDB Page 2 +1 970.879.9900 | sensorsales@standexelectronics.com Environmental Specifications Corrosion Resistance 500 hours salt spray ASTM B-117 Installation Torque 15 Foot-Pounds Maximum Enclosure Nema 1,3,4,6,13 & IEC IP67 Vibration 10 G’s 10 to 2000 Hz Sinusodal Mechanical Shock 50 G’s, 11 mS Half-Sine MFM7-275VPD-RGCD4 Digital Ferrous Metal Detection Sensor Note: Check our website or contact us for details on all our ferrous metal detection options. Absolute Max Limits Min Max Unit Supply Voltage, Vcc -24 +30 Volts DC Voltage at Output -5 +8.5 Volts Reverse Supply Current - 5.0 mA Peak Output Current -10 +10 mA Vout Short Circuit Duration - 10 Minutes Electrical Specifications Conditions Min Max Unit Temperature Range* Operating -40 +110* Deg C Supply Voltage, Vcc Over temperature +8.0 +30 Volts DC Supply Current, Output Off Into Vcc (typ 8) +12 mA Output Current Continuous -1 +1 mA Load Capacitance Cable and Load n/a +1.0 µF Frequency Range Std Programmable 0 500 Hz Frequency Range Max Programmable 0 2000 Hz Digital Voltage Low Vol I sink < 1.0 mA 0 (typ 0.2) Volts Digital Voltage High Voh I source < 1.0 mA 4.60 5.5 Volts Output Rise Time 10-90% Ro=10k, C<100 pF - 5 µS Output Fall Time 90-10% Ro=10k, C<100 pF - 5 µS * T max = 150°C is available, contact factory. Frequency, Detection and Hysteresis are Factory Programmable. Rev D Connections Chart Pin 1 (Red) Vcc Pin 3 (White) Digital Vout Pin 2 (Black) Ground Pin 4 (Green) Program, No Connect CD4-275VPD Caution: A short from the Pin 4 (Green) Program wire to either Pin 1 (Red) Vccor Pin 2 (Black) Ground wire will cause component failure. Functional Characteristics @25°C Min Typ Max Sensor Programming + target ferrous content, shape, & size will affect gaps Output State, No Target Present: Low (~0V) Detect Large Steel Target T=25C Hysteresis, Large Steel Target T=25C .020” .050” .080” Detect 0.5” ø Steel Target - .360” - Detect 0.1” ø Steel Target - .215” - Frequency, Detection and Hysteresis are Factory Programmable and can be decreased upon request.
standexelectronics.comDatasheet Rev DDB Page 3 +1 970.879.9900 | sensorsales@standexelectronics.com Marking Handling Instructions Please note: All technical specifications on this series datasheet refer to the standard product range. Modifications in the sense of technical progress are reserved. For general information only. For more specific information, please consult the product datasheet, available upon request. This series datasheet could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein. These change will be incorporated in future revisions. For deviating values, most current specifications and products please contact your nearest sales office. MFM7-275VPD-RGCD4 Digital Ferrous Metal Detection Sensor Date Code ‘YYM’ YY = YEAR, M = MONTH A JAN D APR H JUL L OCT B FEB E MAY J AUG M NOV C MAR G JUN K SEP N DEC DO NOT CONTACT FACE TO FACE CONTACT WITH OTHER MAGNETS MAY REDUCE THE MAXIMUM OPERATING GAP RG, Linear Regulator DATE CODE, THIS SURFACE CHARACTERISTIC-OPTION_PROGRAMMING MARKED ON THIS SURFACE yy = PROGRAM # 275VPD-RG_yy 06A SENSOR LOAD 5V REG
8 TO 30V
(Ea ch Cha nne l) GND Sensor Funcon MFM7-275VPD