DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 23

Technical content

Features

  • 16 to 50 volt inp ut
  • Up to 87% efficiency W/in3
  • Available to Class H, MIL-PRF-38534
  • Undervoltage lockout
  • -55°C to +125°C operation
  • Fully isolated
  • Magnetic feedback
  • Fixed frequency 500 kHz typical
  • 65 volts for up to sec. transient protection
  • Inhibit and sync function
  • Output short circuit protection MOdeLs Output VOltage (V) SINGLE DUAL 1.8 ±5 2.5 ±7 3.3 ±12 5 ±15 5.2 5.7 Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters Crane Aerospace & Electronics Power Solutions – Interpoint Products 10301 Willows Rd. NE, Redmond, WA 98052 +1 425-882-3100 • power@crane-eg.com www.craneae.com/interpoint Page 1 of 23 16 tO 50 v OLts I n PU t – 25 WAtt MFK Rev AJ - 2016.04.25

Figure 1: MFk singLe bLoCk DiAgrAM Figure 2: MFk DuAL bLoCk DiAgrAM Positive Input Input Common Output Common Positive Output +_+_ Secondary VCC VS+ VRef Secondary VCC PWM Controller VIn UVLO FET Driver Bias SupplyInhibit Sync In Positive Input Input Common Output Common Negative Output Positive Output +_+_ Secondary VCC VS+ VRef Secondary VCC PWM Controller VIn UVLO FET Driver Bias SupplyInhibit Sync In Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters

28 Volt input – 25 Watt

www.craneae.com/interpoint Page 2 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

Figure 3: MFk singLe Pin out (exCePt 28s) Figure 4: MFk DuAL Pin out (inCLuDes 28s) BOTTOM VIEW SINGLES EXCEPT 28 NON-FLANGED OR FLANGED Dot on top of cover indicates pin one. Dotted line outlines flanged package option. 1 2 3 4 7 6 5 BOTTOM VIEW

28 SINGLE AND ALL DUALS

indicates pin one. Dotted line outlines flanged package option. 1 2 3 4 5 8 7 6 PIn O U t Pin s ingle Output MFK2828 s d ual Output

1 Inhibit Inhibit Inhibit

2 Output Common Positive Output Positive Output

3 Positive Output No Connection Output Common

4 Sync In Output Common Negative Output

5 Case Ground Sync In Sync In

6 Input Common Case Ground Case Ground

7 Positive Input Input Common Input Common

8 — Positive Input Positive Input PIns n O t I n Use Inhibit Leave unconnected Sync Leave unconnected tAbLe 1: Pin out tAbLe 2: Pins not in use See Figure 32 on page 18 and Figure 34 on page 20 for dimensions. See Figure 33 on page 19 and Figure 35 on page 21 for dimensions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 3 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

(S = single, D = dual) (R = decimal point, 3R3 = 3.3 Vout) (Standard screening has no designator in this position.) Case Option (Non-flanged case has no designator in this position) sMd nUMbeRs Standard MicrOcircuit drawing (SMd) MFK SiMilar part 5962-1421001HXC MFK281R8S/883 5962-1421002HXC MFK282R5S/883 5962-1421003HXC MFK283R3S/883 5962-1421004HXC MFK2805S/883 5962-1421009HXC IN PROCESS MFK285R2S/883 5962-1421005HXC MFK285R7S/883 5962-1421006HXC MFK2812S/883 5962-1421007HXC MFK2815S/883 5962-1421008HTC MFK2828S/883 5962-1421 101HXC MFK2805D/883 5962-1421102HXC MFK2807D/883 5962-1421103HXC MFK2812D/883 5962-1421104HXC MFK2815D/883 The SMD number shown is for Class H screening, non-flanged. To indicate the flanged case option change the “X” to “Z” In the SMD number (“T” to “U” for 28 single). For exact specifications for an SMD product, refer to the SMD drawing. SMDs can be downloaded from: http://www.landandmaritime.dla.mil/programs/smcr MOdeL nUMbeR O P t IOns tO deterMine the MOdel nuMber enter One OptiOn FrOM each categOry in the FOrM belOw. CAteg ORy base Model and Input voltage Output voltage 1 number of Outputs 2 Case Options 3 screening 4 options MFK28 1R8, 2R5, 3R3, 05 5R2, 5R7, 12, 15, 28 S (non-flanged, leave blank) (standard, leave blank) 05, 07, 12, 15 D F (flanged) ES 883 FILL In FOR M O de L # MFK28 / Notes 2. Number of Outputs: S is a single output and D is a dual output. 3. Case Options: For the standard case, Figure 32 on page 18 or Figure 33 on page 19, leave the case option blank. For the flanged case option, Figure 34 on page 20 or Figure 35 on page 21, insert the letter F in the Case Option position. 4. Screening: For standard screening leave the screening option blank. For other screening options, insert the desired screening level. For more information see Table 1 on page 22 and Table 12 on page 23. Figure 5: MoDeL nuMbering key tAbLe 3: sMD Cross reFerenCe tAbLe 4: MoDeL nuMber oPtions Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 4 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

tAbLe 5: oPerAting ConDitions, ALL MoDeLs, 25°C CAse, 28 vin, 100% LoAD, unLess otHerwise sPeCiFieD. Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. Passes 2000 volts. 3. Dual outputs: The over-current limit will trigger when the sum of the currents from both outputs reaches 115% (typical value) of the maximum rated “total” current of both outputs. 4. Tested with inhibit pin pulled to ground. 5. An external inhibit interface should be used to pull the inhibit low or leave it floating. The inhibit pin can be left unconnected if not used. MFK SERIES A LL M ODELS PARAMETER CONDITIONS MIN TYP MAX UNITS L EAD S OLDERING T EMPERATURE 1 10 SECONDS MAX . — — 300 °C STORAGE TEMPERATURE 1 -65 — +150 °C CASE OPERATING FULL POWER -55 — +125 °C TEMPERATURE ABSOLUTE 1 -55 — +135 DERATING OUTPUT POWER/CURRENT 1 LINEARLY From 100% at 125°C to 0% at 135°C ESD RATING 1 MIL-STD-883, M ETHOD 3015 2000 - 3999 2 V MIL-PRF-38534, 3.9.5.8.2 C LASS ISOLATION: INPUT T O OUTPUT OR ANY 500 VDC A T 25°C 100 — — Megohms PIN T O CASE EXCEPT CASE PIN U NDERVOLTAGE LOCKOUT — 15 — V CURRENT LIMIT 3 % OF FULL LOAD — 115 — % AUDIO REJECTION 1 — 50 — dB CONVERSION FREQUENCY FREE RUN -55°C TO +125°C 430 — 570 kHz SYNCHRONIZATION INPUT FREQUENCY 450 — 550 kHz DUTY CYCLE 1 40 — 60 % ACTIVE LOW — — 0.8 V ACTIVE HIGH 1 4.5 — 5.0 REFERENCED TO INPUT COMMON IF NOT USED LEAVE UNCONNECTED INHIBIT ACTIVE LOW (OUTPUT DISABLED) INHIBIT PIN PULLED LOW 4 — — 0.8 V Do not apply a voltage to the inhibit pin 5 INHIBIT PIN SOURCE — — 4 mA CURRENT 1 REFERENCED TO INPUT COMMON INHIBIT ACTIVE HIGH (OUTPUT ENABLED) INHIBIT PIN CONDITION OPEN COLLECTOR OR Do not apply a voltage to the inhibit pin 5 UNCONNECTED OPEN PIN VOLTAGE 1 8.5 — 12 V For mean time between failures (MTBF) contact Applications Engineering powerapps@crane-eg.com +1 425-882-3100 option 7 Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 5 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

tAbLe 6: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. A minimum load of 20% is recommended. Short circuit measured with 1% 10 milliohm resistive load. 4. Indefinite short circuit protection not guaranteed above 125°C. 5. Recovery and startup times are measured from application of the transient or change in condition to the point at which V OUT is within 1% of final value. C L = 0. 6. Step load transition time 10 µs ±1 µs. 7. Step line transition time 100 µs ±20 µs. 8. Tested on release from inhibit. SINGLE OUTPUT MODELS MFK281R8S MFK282R5S MFK283R3S UNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX OUTPUT CURRENT 2 V IN = 16 TO 50 — — 5.56 — — 5.0 — — 4.55 A OUTPUT POWER 2 VIN = 16 TO 50 — — 10 — — 12.5 — — 15 W OUTPUT RIPPLE TC = 25°C — 30 60 — 30 60 — 25 60 mV p-p 10 kHz - 20 MHz TC = -55°C TO +125°C — 35 80 — 35 80 — 30 80 LINE REGULATION VIN = 16 TO 50 — 5 20 — 5 20 — 5 20 mV LOAD REGULATION NO LOAD TO FULL — 10 25 — 5 25 — 5 25 mV INPUT VOLTAGE CONTINUOUS 16 28 50 16 28 50 16 28 50 V NO LOAD TO FULL TRANSIENT 1 sec.1 — — 65 — — 65 — — 65 V INPUT CURRENT NO LOAD — 25 50 — 25 50 — 25 50 mA INHIBITED — 2.5 4 — 2.5 4 — 2.5 4 INPUT RIPPLE CURRENT 10 kHz - 20 MHz — 30 75 — 30 80 — 30 80 mA p-p EFFICIENCY TC = 25°C 69 72 — 73 76 — 76 79 — % LOAD FAULT 3, 4 POWER DISSIPATION — — 8.5 — — 8.5 — — 8.5 W SHORT CIRCUIT RECOVERY 1 — — 20 — — 20 — — 20 ms STEP LOAD RESPONSE 5, 6 TRANSIENT — 125 200 — 125 200 — 125 200 mV pk 50% - 100% - 50% RECOVERY — 200 400 — 100 300 — 200 300 µs STEP LINE R ESPONSE 1, 5, 7 TRANSIENT — — 350 — — 350 — — 350 mV pk 16 - 50 - 16 V RECOVERY — 0.5 1 — 0.5 1 — 0.5 1 ms START-UP 8 DELAY — — 25 — — 25 — — 25 ms FULL LOAD OVERSHOOT 1 — — 50 — — 50 — — 50 mV pk CAPACITIVE LOAD 1 NO EFFECT ON DC — — 2000 — — 2000 — — 2000 µF TC = 25°C PERFORMANCE Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 6 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

tAbLe 7: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. SINGLE OUTPUT MODELS MFK2805S MFK285R2S MFK285R7S UNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX OUTPUT CURRENT 2 V IN = 16 TO 50 — — 4.0 — — 4 — — 4.0 A OUTPUT POWER 2 VIN = 16 TO 50 — — 20 — — 20.8 — — 22.8 W OUTPUT RIPPLE TC = 25°C — 40 80 — 40 80 — 40 80 mV p-p 10 kHz - 20 MHz TC = -55°C TO +125°C — — 100 — — 100 — — 100 LINE REGULATION VIN = 16 TO 50 — 5 20 — 5 20 — 5 20 mV LOAD REGULATION NO LOAD TO FULL — 5 25 — 5 25 — 5 25 mV INPUT VOLTAGE CONTINUOUS 16 28 50 16 28 50 16 28 50 V NO LOAD TO FULL TRANSIENT 1 sec.1 — — 65 — — 65 — — 65 V INPUT CURRENT NO LOAD — 25 50 — 25 50 — 25 50 mA INHIBITED — 2.4 4 — 2.4 4 — 2.4 4 INPUT RIPPLE CURRENT 10 kHz - 20 MHz — 40 85 — 40 85 — 40 85 mA p-p EFFICIENCY TC = 25°C 79 82 — 79 82 — 79 82 — % LOAD FAULT 3, 4 POWER DISSIPATION — 6 8.5 — 6 8.5 — 6 8.5 W SHORT CIRCUIT RECOVERY 1 — — 20 — — 20 — — 20 ms STEP LOAD RESPONSE 5, 6 TRANSIENT — — 400 — — 400 — — 400 mV pk 50% - 100% - 50% RECOVERY — — 300 — — 300 — — 300 µs STEP LINE R ESPONSE 1, 5, 7 TRANSIENT — — 500 — — 500 — — 570 mV pk 16 - 50 - 16 V RECOVERY — 0.5 1 — 0.5 1 — 0.5 1 ms START-UP 8 DELAY — — 25 — — 25 — — 25 ms FULL LOAD OVERSHOOT 1 — 0 50 — 0 50 — 0 50 mV pk CAPACITIVE LOAD 1 NO EFFECT ON DC — — 2000 — — 2000 — — 2000 µF TC = 25°C PERFORMANCE Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. A minimum load of 20% is recommended. Short circuit measured with 1% 10 milliohm resistive load. 4. Indefinite short circuit protection not guaranteed above 125°C. 5. Recovery and startup times are measured from application of the transient or change in condition to the point at which V OUT is within 1% of final value. C L = 0. 6. Step load transition time 10 µs ±1 µs. 7. Step line transition time 100 µs ±20 µs. 8. Tested on release from inhibit. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 7 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

SINGLE OUTPUT MODELS MFK2812S MFK2815S MFK2828S UNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX OUTPUT CURRENT 2 V IN = 16 TO 50 — — 2.08 — — 1.67 — — 0.89 A OUTPUT POWER 2 VIN = 16 TO 50 — — 25 — — 25 — — 25 W OUTPUT RIPPLE TC = 25°C — 35 80 — 40 80 — 80 150 mV p-p 10 kHz - 20 MHz TC = -55°C TO +125°C — — 100 — 50 100 — 100 200 LINE REGULATION VIN = 16 TO 50 — 5 20 — 5 20 — 150 280 mV LOAD REGULATION NO LOAD TO FULL — 5 20 — 5 20 — 150 280 mV INPUT VOLTAGE CONTINUOUS 16 28 50 16 28 50 16 28 50 V NO LOAD TO FULL TRANSIENT 1 sec.1 — — 65 — — 65 — — 65 V INPUT CURRENT NO LOAD — 20 50 — 20 50 — 30 55 mA INHIBITED — 2.5 4 — 2.5 4 — 2.5 4 INPUT RIPPLE CURRENT 10 kHz - 20 MHz — 45 90 — 50 110 — 50 100 mA p-p EFFICIENCY TC = 25°C 83 86 — 84 87 — 81 84 — % LOAD FAULT 3, 4 POWER DISSIPATION — 6 8.5 — 6 8 — 6 8.5 W SHORT CIRCUIT RECOVERY 1 — — 20 — — 20 — — 20 ms STEP LOAD RESPONSE 5, 6 TRANSIENT — 350 500 — 400 600 — 900 1200 mV pk 50% - 100% - 50% RECOVERY — 300 500 — 300 500 — 500 600 µs STEP LINE R ESPONSE 1, 5, 7 TRANSIENT — — 1300 — — 1500 — — 2800 mV pk 16 - 50 - 16 V RECOVERY — 0.5 1 — 0.5 1 — 0.5 1 ms START-UP 8 DELAY — — 25 — — 25 — — 25 ms FULL LOAD OVERSHOOT 1 — 0 120 — 0 150 — 0 280 mV pk CAPACITIVE LOAD 1 NO EFFECT ON DC — — 2000 — — 2000 — — 1000 µF TC = 25°C PERFORMANCE tAbLe 8: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. A minimum load of 20% is recommended. Short circuit measured with 1% 10 milliohm resistive load. 4. Indefinite short circuit protection not guaranteed above 125°C. 5. Recovery and startup times are measured from application of the transient or change in condition to the point at which V OUT is within 1% of final value. C L = 0. 6. Step load transition time 10 µs ±1 µs 7. Step line transition time 100 µs ±20 µs. 8. Tested on release from inhibit. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 8 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

tAbLe 9: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. DUAL OUTPUT MODELS MFK2805D MFK2807D UNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX OUTPUT CURRENT 2, 3 EITHER OUTPUT — ±2.0 2.80 — ±1.5 2.10 A VIN = 16 TO 50 V T OTAL OUTPUT — — 4.0 — — 3.0 OUTPUT POWER 2, 3 EITHER OUTPUT — ±10 18 — ±10.5 18.9 W VIN = 16 TO 50 V T OTAL OUTPUT — — 20 — — 21 OUTPUT RIPPLE TC = 25°C — — 80 — — 70 mV p-p ±VOUT, 10 kHz - 20 MHz TC = -55°C TO +125°C — — 90 — — 80 LINE REGULA TION + VOUT — 5 20 — 5 20 mV VIN = 16 TO 50 V - VOUT — 20 100 — 20 100 LOAD REGULATION + VOUT — 5 20 — 5 20 mV NL T O F ULL , B ALANCED - VOUT — 35 250 — 50 250 CROSS REGULATION 4 TC = 25°C — — 360 — — 400 mV INPUT VOLTAGE CONTINUOUS 16 28 50 16 28 50 V TRANSIENT 1 sec.1 — — 65 — — 65 V INPUT CURRENT NO LOAD — 30 50 — 30 50 mA INHIBITED — 2.5 4 — 2.5 4 INPUT RIPPLE CURRENT 10 kHz - 20 MHz — 35 70 — 35 70 mA p-p EFFICIENCY TC = 25°C 78 81 — 81 83 — % LOAD FAULT 5, 6 POWER DISSIPATION — 6 8.5 — 6 8 W S HORT C IRCUIT RECOVER Y 1 — 15 20 — 15 20 ms STEP LOAD RESPONSE 7, 8, 9 TRANSIENT ±VOUT — 100 450 — 125 500 mV pk 50%-100%-50%, B ALANCED L OADS RECOVER Y — 200 500 — 200 500 µs STEP LINE RESPONSE 1, 7, 10 TRANSIENT — — 500 — — 700 mV pk ±VOUT , VIN = 16 - 50 - 16 V RECOVERY — 0.5 1 — 0.5 1 ms START-UP 11 DELAY — — 20 — — 20 ms OVERSHOOT 1 — 0 50 — 0 70 mV pk CAPACITIVE LOAD 1, 12 NO EFFECT ON DC — — 1000 — — 1000 µF TC = 25°C PERFORMANCE Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. Up to 70% of the total output power is available from either output providing the opposite output is simultaneously carrying 30% of the total output power. 3. Recommended minimum load is 20% total load (sum of both outputs). Ef fect on –Vout for the following conditions: Short circuit measured with 1% 10 milliohm resistive load. Indefinite short circuit protection not guaranteed above 125°C (case) 7. Recovery and startup times are measured from application of the transient or change in condition to the point at which V OUT is within 1% of final value. C L = 0. Response of either output with the opposite output held at half of the total output power Step load transition time 10 µs ±1 µs. 10. Step line transition time >100 µs. 11. Tested on release from inhibit. 12. Each output. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 9 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

DUAL OUTPUT MODELS MFK2812D MFK2815D UNITSPARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX OUTPUT CURRENT 2, 3 EITHER OUTPUT — ±1.04 1.45 — ±0.833 1.16 A VIN = 16 TO 50 V T OTAL OUTPUT — — 2.08 — — 1.66 OUTPUT POWER 2, 3 EITHER OUTPUT — ±12.5 22.5 — ±12.5 22.5 W VIN = 16 TO 50 V T OTAL OUTPUT — — 25 — — 25 OUTPUT RIPPLE TC = 25°C — — 90 — — 90 mV p-p ±VOUT, 10 kHz - 20 MHz TC = -55°C TO +125°C — — 90 — — 90 LINE REGULA TION + VOUT — 5 20 — 5 20 mV VIN = 16 TO 50 V - VOUT — 20 150 — 20 150 LOAD REGULATION + VOUT — 5 20 — 5 20 mV NL T O F ULL , B ALANCED - VOUT — 60 250 — 100 250 CROSS REGULATION 4 TC = 25°C — — 700 — — 800 mV INPUT VOLTAGE CONTINUOUS 16 28 50 16 28 50 V TRANSIENT 1 sec.1 — — 65 — — 65 V INPUT CURRENT NO LOAD — 30 50 — 30 50 mA INHIBITED — 2.5 4 — 2.5 4 INPUT RIPPLE CURRENT 10 kHz - 20 MHz — 50 100 — 40 100 mA p-p EFFICIENCY TC = 25°C 82 85 — 83 86 — % LOAD FAULT 5, 6 POWER DISSIPATION — 5 8 — 5 8 W S HORT C IRCUIT RECOVER Y 1 — 15 20 — 15 20 ms STEP LOAD RESPONSE 7, 8, 9 TRANSIENT ±VOUT — 350 600 — 400 650 mV pk 50%-100%-50%, B ALANCED L OADS RECOVER Y — 250 550 — 250 550 µs STEP LINE RESPONSE 1, 7, 10 TRANSIENT — — 1300 — — 1500 mV pk ±VOUT , VIN = 16 - 50 - 16 V RECOVERY — 0.5 1 — 0.5 1 ms START-UP 11 DELAY — — 20 — — 20 ms OVERSHOOT 1 — 0 120 — 0 150 mV pk CAPACITIVE LOAD 1, 12 NO EFFECT ON DC — — 1000 — — 1000 µF TC = 25°C PERFORMANCE tAbLe 10: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. Notes 1. Guaranteed by characterization test and/or analysis. Not a production test. 2. Up to 70% of the total output power is available from either output providing the opposite output is simultaneously carrying 30% of the total output power. 3. Recommended minimum load is 20% total load (sum of both outputs). Ef fect on –Vout for the following conditions: Short circuit measured with 1% 10 milliohm resistive load. Indefinite short circuit protection not guaranteed above 125°C (case) 7. Recovery and startup times are measured from application of the transient or change in condition to the point at which V OUT is within 1% of final value. C L = 0. Response of either output with the opposite output held at half of the total output power Step load transition time 10 µs ±1 µs. 10. Step line transition time >100 µs. 11. Tested on release from inhibit. 12. Each output. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 10 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 11 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt Frequency (Hz) MFk2805s inPut riPPLe MFk2805s outPut riPPLe 0.0 -100.0 -20.0 -40.0 -60.0 -80.0 100 1 k 10 k 100 k MFk singLe AuDio rejeCtion Figure 6 Figure 7 Figure 8 Figure 9 MFk2805s steP LoAD 50% - 100%

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 12 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt Figure 10 Figure 11 Figure 12 Figure 13 MFk2805s steP Line 16 - 50 voLts 50% LoAD MFk2805s steP Line 50 - 16 voLts 50% LoAD MFk2805s steP LoAD 100% - 50% MFk2805s stArt-uP FuLL LoAD

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 13 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt Figure 14 Figure 15 Figure 16 Figure 17 MFk281r8s eFFiCienCy MFk282r5s eFFiCienCy MFk283r3s eFFiCienCy 1 4 7 10 WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 42 V 16 V WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 2.5 7 11.5 16 20.5 25 WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 3 6 9 12 15 MFk2805s eFFiCienCy WATTS OUTPUT POWER 20% 100% EFFICIENCY (%)

28 V 50 V

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 14 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt Figure 18 Figure 19 Figure 20 MFk2812s eFFiCienCy MFk2815s eFFiCienCy MFk2828s eFFiCienCy MFK285R7S Efficiency will be added in the future. WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 2.5 7 11.5 16 20.5 25 WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 2.5 7 11.5 16 20.5 25 5 10 15 20 25 WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 15 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt MFk2815D steP LoAD 50% - 100% Frequency (Hz) MFk2815D inPut riPPLe MFk2815D outPut riPPLe 0.0 -100.0 -20.0 -40.0 -60.0 -80.0 100 1 k 10 k 100 k MFk DuAL AuDio rejeCtion Figure 21 Figure 22 Figure 23 Figure 24

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 16 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt Figure 25 Figure 26 Figure 27 MFk2815D steP Line 16 - 50 voLts 50% LoADMFk2815D steP LoAD 100% - 50% Figure 28 MFk2815D steP Line 50 - 16 voLts 50% LoAD MFk2815D stArt-uP FuLL LoAD

tyPiCAL PerForMAnCe PLots: 25°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. For reFerenCe onLy, not guArAnteeD sPeCiFiCAtions. Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 17 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt MFk2805D eFFiCienCy MFk2812D eFFiCienCy Figure 29 Figure 30 WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 2 5 8 11 14 17 20 WATTS 20% 100% EFFICIENCY (%) 28 V 50 V

16 V 42 V

2.5 7 1 1.5 16 20.5 25 MFK2807D Efficiency will be added in the future. Figure 31 MFk2815D eFFiCienCy WATTS OUTPUT POWER 20% 100% EFFICIENCY (%) 28 V 50 V 16 V 42 V 5 10 15 20 25

0.000 0.205 (5.21) 0.605 (15.34) 0.705 (17.91) 0.905 (22.99) 1.105 (28.07) 0.000 0.160 (4.06) 0.960 (24.38) 0.040 dia. (1.02) 1 2 3 4 6 57 BOTTOM VIEW MFK SINGLE 0.360 max (9.14) 0.000 0.25 (6.35) Seam Seal Squared corner and dot on top of case indicate pin one. 1.130 max. (28.70) 1.460 max. (37.08) Weight: 38 grams maximum Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy/Gold ceramic seal Gold plating of 50 - 150 microinches included in pin diameter Seal Hole: 0.123 ±0.002 (3.12 ±0.05) Please refer to the numerical dimensions for accuracy. Case E5, Rev G, 2015.04.21 Figure 32: MFk singLe outPut exCePt 28 voLt singLe Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters 16 tO 50 v OLts I n PU t – 25 WAtt Page 18 of 23 www.craneae.com/interpoint MFK Rev AJ - 2016.04.25

0.000 0.205 (5.21) 0.505 (12.83) 0.705 (17.91) 0.905 (22.99) 1.105 (28.07) 0.000 0.160 (4.06) 0.960 (24.38) 0.030 dia. (0.76) 1 2 4 5 7 6 BOTTOM VIEW MFK DUAL 0.360 max (9.14) 0.000 0.25 (6.35) Seam Seal Squared corner and dot on top of case indicate pin one. 1.130 max. (28.70) 1.460 max. (37.08) Weight: 38 grams maximum Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy/Gold ceramic seal Gold plating of 50 - 150 microinches included in pin diameter Seal Hole: 0.091 ±0.002 (2.31 ±0.05) Please refer to the numerical dimensions for accuracy. Case E6, Rev F, 2015.04.21 Figure 33: MFk DuAL outPut inCLuDes 28 voLt singLe Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters 16 tO 50 v OLts I n PU t – 25 WAtt Page 19 of 23 www.craneae.com/interpoint MFK Rev AJ - 2016.04.25

1.590 (40.39) Flanged cases: Designator "F" required in Case Option position of model number BOTTOM VIEW MFK SINGLE FLANGED 0.205 (5.21) 0.605 (15.34) 0.705 (17.91) 0.905 (22.99) 1.105 (28.07) 1 2 3 4 7 6 5 0.140 (3.56) Squared corner and dot on top of case indicate pin one. 0.560 (14.22) 0.960 (24.38) 0.000 0.160 (4.06) Weight: 38 grams maximum Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy/Gold compression glass seal Gold plating of 50 - 150 microinches included in pin diameter Seal Hole: 0.123 ±0.002 (3.12 ±0.05) Please refer to the numerical dimensions for accuracy. Case G5, Rev F, 2015.04.21 0.000 2 x R 0.130 (3.30) 2 x Dia 0.128 ±0.002 0.360 max (9.14) 0.000 0.25 (6.35) Seam Seal 1.130 max. (28.70) Flange thickness: 0.047 (1.19) Base Plate Detail, Edge View top of header Figure 34: MFk singLe outPut FLAngeD exCePt 28 voLt singLe Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters 16 tO 50 v OLts I n PU t – 25 WAtt Page 20 of 23 www.craneae.com/interpoint MFK Rev AJ - 2016.04.25

1.590 (40.39) 0.205 (5.21) 0.505 (12.83) 0.705 (17.91) 0.905 (22.99) 1.105 (28.07) 1 2 3 4 5 8 7 6 0.140 (3.56) 0.000 Flanged cases: Designator "F" required in Case Option position of model number BOTTOM VIEW CASE MFK DUAL FLANGED Squared corner and dot on top of case indicate pin one. 0.560 (14.22) 0.960 (24.38) 0.000 0.160 (4.06) Weight: 38 grams maximum Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy/Gold compression glass seal Gold plating of 50 - 150 microinches included in pin diameter Seal Hole: 0.091 ±0.002 (2.31 ±0.05) Please refer to the numerical dimensions for accuracy. Case G6, Rev F, 2015.04.21 2 x R 0.130 (3.30) 2 x Dia 0.128 ±0.002 0.360 max (9.14) 0.000 0.25 (6.35) Seam Seal 1.130 max. (28.70) Flange thickness: 0.047 (1.19) Base Plate Detail, Edge View top of header Figure 35: MFk DuAL outPut FLAngeD inCLuDes 28 voLt singLe Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters 16 tO 50 v OLts I n PU t – 25 WAtt Page 21 of 23 www.craneae.com/interpoint MFK Rev AJ - 2016.04.25

Table is for reference only. See individual Series' datasheets for specific screening. tAbLe 8: eLeMent evALuAtion HigH reLiAbiLity DC-DC Converters AnD eMi FiLters /883 (CLAss H) eleMent eValuatiOn 1 high reliability /883 (claSS h) QMl claSS h /883 cOMpOnent-leVel teSt perFOrMed M/S 2 p 3 Element Electrical n n Visual n n Internal Visual n Final Electrical n n Wire Bond Evaluation n n Notes 1. Element evaluation does not apply to standard and /ES product. 2. M/S = Active components (microcircuit and semiconductor die). 3. P = Passive components, Class H element evaluation. Not applicable to standard and /ES element evaluation. tAbLe 11: eLeMent evALuAtion Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters www.craneae.com/interpoint Page 22 of 23 MFK Rev AJ - 2016.04.25 16 tO 50 v OLts I n PU t – 25 WAtt

Table is for reference only. See individual Series' datasheets for specific screening. tAbLe 9: environMentAL sCreening HigH reLiAbiLity DC-DC Converters AnD eMi FiLters stAnDArD, /es AnD /883 (CLAss H) enVirOnMental Screening high reliability Standard, /eS and /883 (claSS h) nOn-QMl 1 QMl 2 teSt perFOrMed Standard /eS claSS h /883 Pre-cap Inspection, Method 2017, 2032 n n n temperature Cycle (10 times) Method 1010, Cond. C, -65°C to +150°C, ambient n Method 1010, Cond. B, -55°C to +125°C, ambient n Constant Acceleration Method 2001, 3000 g n Method 2001, 500 g n PInd, test Method 2020, Cond. A n 3 burn-in Method 1015, +125°C case, typical 4 96 hours n 160 hours n Final electrical test, MIL-PRF-38534, group A, Subgroups 1 through 6, -55°C, +25°C, +125°C case n Subgroups 1 and 4, +25°C case n n Hermeticity test Gross Leak, Cond. C1, fluorocarbon n n Fine Leak, Cond. A2, helium n n Gross Leak, Dip n Final visual inspection, Method 2009 n n n Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534. Notes 1. Standard and ES are non-QML products and may not meet all of the requirements of MIL-PRF-38534. 2. All processes are QML qualified and performed by certified operators. 3. Not required by DLA but performed to assure product quality. 4. Burn-in temperature designed to bring the case temperature to +125°C minimum. Burn-in is a powered test. tAbLe 12: environMentAL sCreening Crane Aerospace & Electronics Power Solutions MFK single and d ual d C- d C Converters MFK Single and Dual, MFK Rev AJ - 2016.04.25. This revision supersedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Crane Electronics, Inc reserves the right to make changes in products or specifications without notice. Interpoint is a registered trademark of Crane Co. MFK Series is a trademark of Crane Electronics, Inc. Copyright © 1999 - 2016 Crane Electronics, Inc. All rights reserved. www.craneae.com/interpoint Page 23 of 23 16 tO 50 v OLts I n PU t – 25 WAtt