Technical content

Specifications All Specifications are typical at nominal input, full load at 25 °C unless otherwise stated . AC Input 100-240Vac, +/-10%, 47-63 Hz, 1∅ MTBF >100,000 hours calculated Input Current 100Vac: 1.35A Hold -up Time 18 ms min. @ 115Vac, 60 ms min. @ 230 Vac Inrush Current 60A peak @ 264Vac, cold start Overload Protection Hiccup Mode Input Fuse 3.15A, 250V Internal Primary Current Fuse provided Short Circuit Protection Hiccup Mode Efficiency Meets International Efficiency Level V Topology Switching – Fixed Frequency Flyback Output Voltage See chart Safety and EMC Approvals EN/IEC/CSA/UL60601-1 EMC: See chart Output Power See chart Dielectric Withstand Input-Output: 5,656Vdc Input-GND: 1,500 Vac, Output-GND: 500Vdc Ripple and Noise 1% pk-pk max., 20MHz BW Operating Temperature 0° to 40 °C, no derating Line/Load Regulation Line: +/- 1 to 2%, Load: +/-5% at end of cable Storage Temperature -30 to +85 °C Transient Response 500 µs max., 50% load step, typical Relative Humidity 5% to 95%, non-condensing Minimum Load Not required Altitude 0 to 10,000 ft Case Material Black 94V0 Polycarbonate Output Connections Cable: 20AWG, 1,800mm, 4 conductor Connector: Ault #3, 2.5mm barrel or #51, 6-pin Molex (12V model) Case Dimensions 131 x 72 x 43mm See outline drawing Weight 500g EMI/EMC Compliance Conducted Emissions FCC Part 15, Class B, EN55011 Class B, EN55024 Radiated Emissions FCC Part 15, Class B, EN55011 Class B, EN55024 Voltage Fluctuations EN61000-3-3, Line Flicker Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz.. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 crit. A, 100Vac 60Hz, 40%/5 cycles with 70% full load. Line Frequency Harmonics EN61000-3-2, Class A MENB1080 Universal Input 80 Watt Series

  • 100-240VAC Universal Input
  • Meets EISA2007, CEC Efficiency Level V, EU (EC) No 278/2009 Phase II
  • Desktop Style
  • 12V to 24V Single Output Models, up to 80W
  • Modified and Custom Designs Available
  • Regulated Output with Low Ripple
  • Impact-Resistant Polycarbonate Enclosure
  • No Load Power Consumption <0.5W
  • Certified to UL/EN/IEC60601-1 Medical Switch-Mode Power Supply 3 Year Warranty

"01" = Standard. "02" and higher indicates a modif ied model. Model Output Voltage: "05" = 5Vdc, "12" = 12Vdc, "24" = 24Vdc, etc. Input Connector: "F" = IEC320 C14 grounded, Other options available, see below Output Connector: "03" = 2.5mm Barrel Type Connector, "51" = 6 pin Mo lex. Other options available. Model "A" = Original Configuration Product Family : "M" = Medical, "E" = External, "NB" = Model Serie s Designator Output Pow er: "080" = 80 Watts # of Outputs "1" = Single Output Input Receptacle Output Connector Output Connector (12V Model) IEC320 C14 - Class I Grounded (F) “#3” Connector is 2.5mm barrel type, center (+) “#51 ” Connector is Molex 39-01-2060 or equivalent . "51" Connector Pinout: Pins 1, 4: (+), Pins 3, 6: (-). Mate = Molex 39-01-2061 or equiv. Ault #3 connector shown. Dimensions are in mm Data Sheet © 2011 SL Power Electronics Corp. The i nformation and specifications contained herein are believed to be correct at the time of publication. Rev. 4-25-2011 However, SL Power accepts no responsibility for con sequences arising from reproduction errors or inacc uracies. Specifications are subject to change with out notice. Model Number Volts (V) Output Current (max) Max Watts Ripple (Vp-p max) MENB1080A1251F01 12 V 6.5 A 78.0 W 120mV MENB1080A1503F01 15 V 5.2 A 78.0 W 150mV MENB1080A1803F01 18 V 4.33 A 78.0 W 180mV MENB1080A2403F01 24 V 3.25 A 78.0 W 240mV Outline Drawing MENB1080 Universal Input 80 Watt Series Medical Switch-Mode Power Supply 3 Year Warranty