MEJ2_V01 MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 1 of 10 www.murata.com www.murata.com For full details go to https://www.murata.com/en- global/products/power/rohs SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise (Typ)3 Ripple & Noise (Max)3 Efficiency (Min) Efficiency (Typ) MTTF2 Recommended Alternative V V mA % mVp-p % kHrs MEJ2S0303SC 3.3 3.3 606 756 14.0 17 38 55 67 70 3910 MEJ2S0305SC 3.3 5 400 784 13.0 15 50 65 70 74 3757 MEJ2S0503SC 5 3.3 606 528 10.0 15 40 55 67 70 3830 MEJ2S0505SC 5 5 400 503 8.5 10 43 55 72 75 3654 MEJ2S0509SC 5 9 222 505 8.0 11 36 50 75 78 3472 MEJ2S0512SC 5 12 167 495 8.0 12 40 55 74 77 3663 MEJ2S0515SC 5 15 133 488 7.0 10 34 45 76 79 2629 MEJ2S1203SC 12 3.3 606 207 9.5 11 43 60 70 73 3259 MEJ2S1205SC 12 5 400 214 8.0 10 43 60 75 78 3200 MEJ2S1209SC 12 9 222 205 7.0 10 35 50 75 79 2453 MEJ2S1212SC 12 12 167 207 6.5 8 35 50 76 80 2779 MEJ2S1215SC 12 15 133 205 7.0 10 32 45 76 80 2707 MEJ2S1505SC 15 5 400 171 8.5 10 44 60 73 76 2638 MEJ2S1509SC 15 9 222 165 6.5 8 35 50 74 78 2203 MEJ2S1512SC 15 12 167 164 6.5 8 38 55 74 79 2330 MEJ2S1515SC 15 15 133 166 7.0 8 36 50 74 78 2100 MEJ2D0503SC 5 ±3.3 ±303 535 8.5 10 26 40 67 71 3969 MEJ2D0505SC 5 ±5 ±200 508 7.5 9 34 50 72 76 3654 MEJ2D0509SC 5 ±9 ±111 510 6.5 8 27 40 76 79 3472 MEJ2D0512SC 5 ±12 ±83 504 5.0 8 27 40 74 77 3663 MEJ2D0515SC 5 ±15 ±67 492 7.0 9 20 35 74 78 2629 MEJ2D1205SC 12 ±5 ±200 212 7.0 8 32 45 75 79 3268 MEJ2D1209SC 12 ±9 ±111 206 5.5 7 27 40 77 81 2453 MEJ2D1212SC 12 ±12 ±83 208 5.5 7 27 40 77 81 2779 MEJ2D1215SC 12 ±15 ±67 203 6.0 7 24 40 78 82 2707 MEJ2D1505SC 15 ±5 ±200 170 7.0 9 37 50 74 78 2638 MEJ2D1509SC 15 ±9 ±111 163 5.5 7 26 40 76 80 2203 MEJ2D1515SC 15 ±15 ±67 167 5.5 7 23 35 75 79 2100 MEJ2D1203SC 12 ±3.3 ±303 205 8.0 9 37 55 72 75 3270 MEJ2S1203SC MEJ2D1512SC 15 ±12 ±83 167 5.5 7 26 40 75 80 2330 Contact Murata INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range Continuous operation, 3V input types 2.97 3.3 3.63 VContinuous operation, 5V input types 4.5 5 5.5 Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 15V input types 13.5 15 16.5 Input reflected ripple 3.3V input types 100 140 mA5V input types 60 90 12V & 15V input types 22 40 1. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load. 2. See safety approvals section for limitations of use. 3. See ripple & noise test method. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
RoHS compliant Basic/supplementary isolation to UL609502 ANSI/AAMI ES60601-1 Power density 0.81W/cm3 Single and dual outputs UL 94V-0 package material Footprint 1.96cm2 SIP package style 5.2kVDC isolation ‘Hi Pot Test’ 3.3V, 5V, 12V & 15V inputs 3.3V, 5V, 9V, 12V & 15V outputs Internal SMD construction Fully encapsulated with toroidal magnetics Pin compatible with the MEV, NMV, NMK & NMJ series MTTF up to 3.9 million hours Characterised CMTI >200kV/μS Continuous barrier withstand voltage 2.4kVDC PRODUCT OVERVIEW The MEJ2 series are single and dual output medically approved DC-DC converters in a 7 pin SIP package style offering a power upgrade path from the NMJ series SIP DC-DC converters. The MEJ2 series is UL60950 and ANSI/AAMI ES60601-1 recognised, which makes it ideal for applications where safety and miniaturisation are of paramount importance.
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 2 of 10 www.murata.com ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 5200 VDC Resistance Viso= 500VDC 1G Ω Isolation capacitance 4p F Continuous barrier withstand voltage Non-safety barrier application 2400 V Safety standard UL60950-1 Basic/supplementary 200 VrmsANSI/AAMI ES60601-1 1 MOOP 200 GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency All types 45 kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specification All output types (see safety approval section for limitations) -40 85 Storage -55 125 Case Temperature above ambient MEJ2S0509SC, MEJ2S0512SC, MEJ2S0515SC, MEJ2S1209SC, MEJ2x1212SC, MEJ2S1215SC, MEJ2S1509SC, MEJ2S1512SC, MEJ2S1515SC 27 MEJ2S0503SC, MEJ2S0505SC, MEJ2S1203SC, MEJ2S1205SC, MEJ2x1505SC, MEJ2S1515SC, MEJ2D0512SC, MEJ2D0515SC, MEJ2D1209SC, MEJ2D1215SC 30 MEJ2S0305SC, MEJ2S0303SC, MEJ2S1203SC, MEJ2D0505SC, MEJ2D0509SC, MEJ2D1205SC, MEJ2D1509SC, MEJ2D1512SC 33 MEJ2D01203SC, MEJ2D0503SC 37 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Short-circuit protection 10 minutes Lead temperature 1mm from case for 10 seconds 260°C Wave Solder Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. Input voltage VIN, MEJ2x03xxSC 5V Input voltage VIN, MEJ2x05xxSC 7V Input voltage VIN, MEJ2x12xxSC 15V Input voltage VIN, MEJ2x15xxSC 18V OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated Power2 TA=-40ºC to 85ºC 2W Voltage Set Point Accuracy See tolerance envelopes Line regulation High V IN to low VIN 1.0 1.2 %/%
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 3 of 10 www.murata.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MEJ2 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 5.2kVDC for 1 second. The MEJ2 series is recognised by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the MEJ2 series is not used as a safety barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier up to 2.4kV are sustainable. This is established by measuring the partial discharge Inception voltage in accordance with IEC 60270. Please contact Murata for further information. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The MEJ2 series have recognised by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOOP (Means Of Operator Protection) based upon a working voltage of 200 Vrms max and 280 Vpk max., between Primary and Secondary and between Primary and its Enclosure, in a maximum ambient temperature of 85°C and/or case temperature limit of 130°C (case temperature measured on the face opposite the pins). File Number E202895 applies. UL60950 The MEJ2 series have been recognised by Underwriters Laboratory (UL) to UL60950 for basic/supplementary insulation to a working voltage of 200Vrms in a maximum ambient temperature of 85°C and/or case temperature limit of 130°C (case temperature measured on the face opposite the pins). File number E151252 applies. Creepage and clearance 2mm Working altitude 4000m FUSING The MEJ2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. MEJ2x03xxxC: 2A MEJ2x05xxxC: 2A MEJ2x12xxxC: 750mA MEJ2x15xxxC: 750mA All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. Please refer to application notes for further information. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata.com/en-global/products/power/ rohs
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 4 of 10 www.murata.com PART NUMBER STRUCTURE MEJ 2 X XX XX S C Series name Power rating Output type S - Single D - Dual T - Triple Q - Quad RoHS compliant Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltage Input voltage ENVIRONMENTAL VALIDATION TESTING The following tests have been conducted on this product series, as part of our design verification process. The datasheet characteristics specify user operating conditions for this series, please contact Murata if further information about the tests is required. Test Standard Condition Temperature cycling MIL-STD-883 Method 1010, Condition B 10 cycles between two chambers set to achieve -55°C and +125°C. The dwell time shall not be less than 10min. Humidity bias JEDEC JESD22-A101 85°C ± 2°C, 85% ± 5% R.H. for >1000 hours. Storage life JEDEC JESD22-A103, Condition A 125°C +10/-0°C for ≥1000 hours. Vibration MIL-STD-883 Method 2007, Condition A 1.5mm pk-pk / 20g pk min, 20-2000Hz, 4 sweeps in each of 3 mutually perpendicular axis at 3 oct/min. Shock MIL-STD-883 Method 2002, Condition A 500g 1.0ms half sine, 5 shocks in each direction of 3 mutually perpendicular axes. ESD JESD22-A114 HBM Testing Standard at 3 stress levels; 2.0kV, 4.0kV and 8.0kV. Bump IEC Class 4M5 ofETS 300 019-2-4 Shock Spectrum Type II, 6mS duration, 250m/s 2 500 bumps in 6 directions. Solderability IPC/ECA J-STD-002, Test A and A1 SnPb (Test A) For leaded solderability the parts are conditioned in a steam ager for 8 hours ±15 min. at a temperature of 93±3°C. Dipped in solder at 245°C ±5°C for 5 (+0/-0.5) seconds. Pb-free (Test A1) For lead free solderability the parts are conditioned in a steam ager for 8 hours ± 15 min. at a temperature of 93±3°C. Dipped in solder at 255°C ±5°C for 5 (+0/-0.5) seconds. Solder heat JEDEC JESD22-B106 The test sample is subjected to a molten solder bath at 260 ±5°C for 10 seconds (96SC tin/ silver/copper). Solder heat (hand) MIL-STD-202 Method 210, Condition A The soldering iron is heated to 350°C ± 10°C and applied to the terminations for a duration of 4 to 5 seconds. Solvent cleaning Resistance to cleaning agents. Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C- 65°C. Solvent Resistance MIL-STD-883 Method 2015 Separate samples subjected to solvent A, solvent B and solvent D. Lead Integrity (Adhesion) MIL-STD-883 Method 2025 Leads are bent through 90º until a fracture occurs. Lead Integrity (Fatigue) MIL-STD-883 Method 2004, condition B 2 The leads are bent to an angle of 15º. Each lead is subjected to 3 cycles. Lead Integrity (Tension/Pull) MIL-STD-883 Method 2004, Condition A 1 Pull of 0.227kg applied for 30 seconds. The force is then increased until the pins snap.
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 5 of 10 www.murata.com APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Gate Drive Applications Advisory Note For general guidence for product usage in gate drive applications please refer to “gate drive application notes”. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Typical Start-Up Wave Form Start-up time μs MEJ2S0303SC 0.89 MEJ2S0305SC 1.89 MEJ2S0503SC 1.08 MEJ2S0505SC 2.04 MEJ2S0509SC 6.5 MEJ2S0512SC 8.29 MEJ2S0515SC 11.4 MEJ2S1203SC 0.73 MEJ2S1205SC 1.61 MEJ2S1209SC 4.04 MEJ2S1212SC 5.51 MEJ2S1215SC 7.61 MEJ2S1505SC 1.33 Start-up time μs MEJ2S1509SC 3.37 MEJ2S1512SC 4.47 MEJ2S1515SC 6.05 MEJ2D0503SC 1.57 MEJ2D0505SC 1.79 MEJ2D0509SC 9.32 MEJ2D0512SC 14.9 MEJ2D0515SC 20.84 MEJ2D1203SC 1.03 MEJ2D1205SC 2.51 MEJ2D1209SC 6.46 MEJ2D1212SC 9.94 MEJ2D1215SC 14.54 Start-up time μs MEJ2D1505SC 1.79 MEJ2D1509SC 5.16 MEJ2D1512SC 7.04 MEJ2D1515SC 10.48 CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic OSCILLOSCOPE YI N P U T SUPPLY C1 C2 C3 R1 T1 R2 Input Output DC/DC Converter RL O A D + +
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 6 of 10 www.murata.com TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. MEJ2X0303SC MEJ2D0515SC All Other Variants 10% 2.5% -7.5% Output Load Current (%) Output Load Current (%) Output Load Current (%) Output Voltage Output Voltage Output Voltage 100 100 10075 7550 5025 2510 -7% 1%2% 0% -17% -7% TEMPERATURE DERATING GRAPH UL60950 recognition to a maximum ambient temperature of 85ºC and/or case temperature limit of 155ºC, measured on the face opposite the pins. 85400-40 0.2 1.0 2.0 Ambient Temperature (ºC) Output Power (W) Safe Operating Area
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 7 of 10 www.murata.com EFFICIENCY VS LOAD MEJ2S03XXSC MEJ2S05XXSC MEJ2S12XXSC MEJ2S15XXSC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 3.3V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V 3.3V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V 3.3V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 8 of 10 www.murata.com EFFICIENCY VS LOAD (Continued) MEJ2D05XXSC MEJ2D12XXSC MEJ2D15XXSC 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V 3.3V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V 3.3V 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Efficiency (%) Load (%) 12V 15V
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 9 of 10 www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS Single Output Pin Function 1 +Vin 2 -Vin 5 -Vout 7 +Vout Dual Output Pin Function 1+ V IN 2- V IN 5- V OUT 6* OV 7+ V OUT TUBE OUTLINE DIMENSIONS RECOMMENDED FOOTPRINT DETAILS Weight: 4.3g 6.00 (0.236) 5.00 (0.197) 5.20 (0.205) 1.50 (0.059) 0.6±0.15 14.20 (0.559) (0.024±0.006) Unless otherwise stated all dimensions in mm ±0.5mm (inches ±0.02). Tube length : 20.669±0.079 (525mm±2mm). Tube Quantity : 25 All dimensions in mm (inches). Controlling dimension is mm. All pins on a 2.54 (0.100) pitch and within ±0.1 (0.004) of true postion from pin 1 at seating plane ‘S’ * Pin not fitted on single output variants. * Hole not required for single output variants. All dimensions in mm ±0.25mm (inches ±0.01).
5.2kVDC Isolated 2W DC-DC Converters KDC_MEJ2_M01 Page 10 of 10 www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2023 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment ( automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.