DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

MegaPAC™ Family Rev 1.6 Page 1 of 10 03/2016 User- and Field-Configurable Power Supplies MegaPAC™ Family AC-DC and DC-DC Switchers Features & Benefits

  • AC inputs available: 85 – 264VAC, 208 / 240VAC 3-Phase
  • Power factor corrected (some models)
  • Up to 4kW
  • DC inputs available: 100 – 380VDC
  • User and field configurable
  • Compact sizes as small as 3.4 x 6.0 x 9.5in [86.4 x 152.4 x 241.3mm]
  • Fan cooled
  • Efficiency >80%
  • Up to 20 regulated outputs (up to 10 slots) from 1 to 95VDC and above
  • Full power to 45°C on most products
  • OVP, OTL, OCP on most outputs
  • Autosense
  • Power fail warning
  • Sequencing and general shut down
  • Agency approved cTÜVus, CE Marked
  • Current Sharing
  • Low leakage option available (some models) Product Description The MegaPAC family of products offers four different versions of user configurability to meet almost any set of input and output requirements. Leveraging Vicor modular DC-DC converters, MegaPAC family products combine feature-laden front ends with slide-in output assemblies called ConverterPACs. User configurability is at the heart of every MegaPAC. A wide variety of the same length ConverterPACs™ can be installed, exchanged or removed with the turn of just one screw. This means the MegaPAC can be reconfigured to meet evolving power requirements. Given its range of configurability, the MegaPAC is appropriate for virtually any application from prototype through production. PFC MegaPAC-EL/HPEL 15.6 x 6.0 x 3.4in [396.2 x 152.4 x 86.4mm] Up to 2400W at 230VAC 1 – 16 Outputs (8 Slots) PFC MegaPAC/HP 12.3 x 6.0 x 3.4in [312.4 x 152.4 x 86.4mm] Up to 2400W at 230VAC 1 – 16 Outputs (8 Slots)

MegaPAC™ Family Rev 1.6 Page 2 of 10 03/2016 MegaPAC™ Family MegaPAC Family MegaPAC Configuration [a] Low noise ripple for EL power supplies is 10mVP-P or 0.15% whichever is greater. [b] ConverterPACs with Maxi module Model Dimension Input Voltage Output Power Number of Outputs ConvertPACs™ Per Slot Mini MegaPAC™ 9.5 x 6.0 x 3.4in [241.3 x 152.4 x 86.4mm] 90 – 132 / 180 – 264VAC Strappable 260 – 380VDC 1,000W @ 115VAC or 230 Vac 1 – 10 (5 slots) ModuPAC™, JrPAC™, DualPAC™, RamPAC™, BatPAC™ PFC MegaPAC-EL/HPEL™ [a] 15.6 x 6.0” x 3.4in [396.2 x 152.4 x 86.4mm] 85 – 264VAC 100 – 380VDC 1,200W @ 115VAC 2,400W @ 230VAC 1 – 16 (8 slots) QPAC™, DualQPAC™, JrQPAC™, FinQPAC™ [b] (FinQPAC requires 2 slots) PFC MegaPAC/HP™ 12.3 x 6.0 x 3.4in [312.4 x 152.4 x 86.4mm] 85 – 264VAC 100 – 380 Vdc 2,400W @ 230VAC 1,200W @ 115VAC 1 – 16 (8 slots) ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC, FinPAC™ [a] (FinPACs require 2 slots) 4kW MegaPAC™ 14.0 x 7.5 x 4.9in [355.6 x 190.5 x 124.5mm] 208 or 240VAC Three Phase 260 – 352VDC 4,000W – 3 phase 1 – 20 (10 slots) ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC, UniPAC™ [b] DC-DC Converter At the heart of every MegaPAC are Vicor zero-current switching, DC-DC converters. The modularity of the design combined with the breadth of the product line means virtually any output voltage can be provided. ConverterPAC ConverterPACs are the slide-in output assemblies that allow each MegaPAC to be easily configured to user-specified output requirements. Using the Vicor DC-DC converter, up to 600W of output power can be provided per ConverterPAC. Larger power needs are easily handled by paralleling ConverterPACs. MegaPAC Each MegaPAC houses an array of user-selected ConverterPACs to provide a customized power supply. Using a different front end for each product line, almost any input power can be accommodated. The result is a customized power supply with off-the-shelf delivery.

MegaPAC™ Family Rev 1.6 Page 3 of 10 03/2016 MegaPAC™ Family Performance Specifications Typical at 25ºC, nominal line and 75% load, unless otherwise specified Parameter PFC MegaPAC™, PFC MegaPAC-HP™, PFC MegaPAC-HPEL™, PFC MegaPAC-EL™ Mini MegaPAC™ 4kW MegaPAC™ Input Charactersitics Input 85 – 264VAC 115 – 230VAC, Strappable 208 / 240VAC, 3-phase, 4 wire 180 – 264VAC 1-phase Standard Line 47 – 500Hz Vantage Line 47 – 63Hz 100 – 380VDC 260 – 380VDC 260 – 352VDC Line Regulation 0.2% max from 10% to full load Inrush Current 25APK at 115VAC 80APK at 115 and 230VAC 30APK at 230VAC 25APK at 230VAC Ride-Through Time >20ms at nominal line, full load Power Fail >3ms warning Conducted EMI (47 – 63Hz) EN 55022 Level B (certain configurations) EN 55022 Level A EN 55022 Level A FCC B Power Factor 0.99 (115VAC) 0.65 0.92 (3-phase operation) 0.98 (230VAC) Surge Immunity (Common Mode & Normal Mode) EN 61000-4-5 Class 3, Performance Critera B Output Charactersitics Load Regulation 0.2% max from 10% to full load 0.5% from no load to 10% load Set-Point Accuracy Standard Line:1.0% for standard voltages, 2.0% for special or adjustable voltages Vantage Line: 2.0% for standard voltages, 5.0% for special or adjustable voltages See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage. Ripple and Noise (20MHz BWL) Standard outputs: 2% or 100mVP-P max whichever is greater, 10% minimum load VXI options: 50mVP-P max for outputs, ≤15VDC; 150mVP-P max. 15V < VOUT ≤ 24V; 1% VOUT > 24V 2nd Generation QPAC, FinPAC, FinQPAC and UniPAC performance dependent on the converter module used. (Output of module is unfiltered.) QPAC, DualQPAC, JuniorQPAC, RamPAC: 10mVP-P max or 0.15%, whichever is greater. Overcurrent Protection 105 –130% > 5V outputs 30 – 125% ≤ 5V outputs Overvoltage Protection ModuPACs and QPACs: 115 – 135% Efficiency 80% typical 82% typical 82% typical Output Power 1,600W at 40°C (230VAC) PFC MegaPAC; PFC MegaPAC-EL (Low Noise) 1,000W at 45°C (115 / 230VAC) 4,000W at 45°C (3-phase) 2,400W at 40°C (230VAC) PFC MegaPAC HP , PFC MegaPAC HPEL 1,500W at 45°C (1-phase) 1,200W at 40°C (115VAC) PFC MegaPACs

MegaPAC™ Family Rev 1.6 Page 4 of 10 03/2016 MegaPAC™ Family Performance Specifications (Cont.) Typical at 25ºC, nominal line and 75% load, unless otherwise specified Parameter PFC MegaPAC™, PFC MegaPAC-HP™, PFC MegaPAC-HPEL™, PFC MegaPAC-EL™ Mini MegaPAC™ 4kW MegaPAC™ Environmental Storage Temperature –40 to +85ºC Operating Temperature [c] Vantage Line Full Power 0 to +40ºC 0 to +45ºC 0 to +45ºC Vantage Line Half Power 0 to +60ºC 0 to +65ºC 0 to +65ºC Standard Line Full Power –20 to +40ºC –20 to +45ºC –20 to +45ºC Standard Line Half Power –20 to +60ºC –20 to +65ºC –20 to +65ºC Safety Agency Approvals cTÜVus CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable Product Weight (Fully Configured) 9.75lbs [4.43kg] (PFC MegaPAC & HP) 13.0lbs [6.0kg] (PFC MegaPAC HPEL) Limited Warranty 2 Years [c] PFC MegaPACs: The maximum operating temperature is 40°C. If using a VI-200™ with output voltage <12V and >150W, the operating temperature decreases to 35°C. This also applies when using a FinPAC™ with output voltage <24V and >500W. Mini MegaPAC & 4kW MegaPACs: The operating temperature is 45°C using any combination of modules and output voltages as long as the front-end rating is not exceeded. Normal derating applies to half power if the ambient temperature is 20°C hotter.

MegaPAC™ Family Rev 1.6 Page 5 of 10 03/2016 MegaPAC™ Family ConverterPAC™ Overview nn Output voltages from 2 – 95VDC nn Output power up to 600W nn DC OK nn Adjustment ranges from 50% to 110% of nominal nn Autosense / Remote Sense nn Low noise option:10mVP-P or 0.15%, whichever is greater nn 80 – 90% efficiency nn Current source outputs available MegaPAC Configuration for MegaPAC Family Product Converters Module(s) Used Maximum Output Power VE-200 and VE-J00 ConverterPACs ModuPAC™ (M) (RoHS – GM) 1 VE-200 DC-DC Converter Up to 200W per ConverterPAC RamPAC™ (R) (RoHS – GR)

1 VE-J00 DC-DC Converter

1 Ripple Attenuator Module (VI-RAM) Up to 100W for applications requiring low ripple / noise

DualPAC™ (D) (RoHS – GD) 2 VI-J00™ DC-DC Converters Dual Output; Up to 100W each output JuniorPAC™ (J) (RoHS – GJ) 1 VI-J00 DC-DC Converter Up to 100W BatPAC™ (B) (RoHS – GB) 1 VI-200™ BatMod A 200W programmable current source that can be configured as a battery charger QPAC™ [d] Low Noise (L) (RoHS – GL)

1 VI-200 DC-DC Converter

with differential- and common-mode filters Up to 200W for applications requiring as low as 10mVP-P output noise JrQPAC™ [d] Low Noise (LJ) (RoHS – GLJ) with differential- and common-mode filters Up to 100W DualQPAC™ [d] Low Noise (LD) (RoHS – GLD)

2 VI-J00 DC-DC Converters

with differential- and common-mode filters Dual Output; Up to 100W each output Maxi ConverterPACs UniPAC™ (XU) (RoHS – GXU) 1 Maxi DC-DC Converter Up to 500W; Applicable for 3-phase / 4kW product FinPAC™ [e] (PZ) (RoHS – GPZ) 1 Maxi DC-DC Converter Up to 600W; Applicable for PFC MegaPAC High Power FinQPAC™ [e] (PZL) (RoHS – GPL)

1 Maxi DC-DC Converter

with discrete output filter Up to 600W; Applicable for PFC MegaPAC-HPEL [d] Only for the extended-length MegaPACs [e] FinPACs and FinQPACs require two (2) slots.

MegaPAC™ Family Rev 1.6 Page 6 of 10 03/2016 MegaPAC™ Family MegaPAC Mechanical Drawings Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.

14 AWG WIRE

M4 OR #8-32 THREAD MAXIMUM SCREW PENETRATION .150 (4.00 MM) INPUTS DO NOT WITHOUT EARTH GROUND 115/230 VAC 300VDC

47 TO 500 Hz

CUSTOMER MOUNTING HOLES (16X) FROM OUTSIDE SURFACE. 5.10 (129,5) FAN (DIRECTION OF AIR FLOW OPTIONAL) 6.04 (153,42) 3.37 (85,60) 11.93 (302,90) 2.92 (74,17) 0.21 (5,33) 0.25 (6,35) 5.100 (129,54) 0.47 (11,94) 12.24 (310,82) 0.64 (16,31) 0.41 (10,35) 2.77 (70,23) 1.40 (35,56) 0.470 (11,94) 0.729 (18,52) 1.458 (37,03) NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS TORQUE = 4.4 INCH POUNDS NOTE: SET SCREW MAXIMUM LABEL NO: 94-00046 REV B LABEL NO: 94-00046 REV B MP6-78600 1600001 057 D PFC MegaPACMegaPAC 3.275 (83,19) M4 OR #8-32 THREAD MAXIMUM FROM OUTSIDE SURFACE. SCREW PENETRATION 0.150 (4,00) CUSTOMER MOUNTING HOLES (4X) 1/4 - 20 SERRATED FLANGED WITH OPTIONAL BUSS BARS NUT ZINC PLATED STEEL CUSTOMER MOUNTING HOLES (4X) M4 OR #8-32 THREAD MAXIMUM SCREW PENETRATION 0.150 (4,00) FROM OUTSIDE SURFACE. FAN (DIRECTION OF AIR FLOW OPTIONAL) 6.04 (153,42) 3.37 (85,60) 5.100 (129,54) 0.470 (11,94) 0.210 (5,33) 2.920 (74,17) 15.185 (385,70) 15.090 (383,29) 0.250 (6,35) 2.77 (70,23) 1.40 (35,56) 0.470 (11,94) 0.729 (18,52) = 5.10 (129,5) 0.41 (10,35) 0.64 (16,32) 3.275 (83,19) NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS TORQUE = 4.4 INCH POUNDS NOTE: SET SCREW MAXIMUM LABEL NO: 94-00046 REV B LABEL NO: 94-00046 REV B PFC MegaPAC-EL PFC MegaPAC™ / PFC MegaPAC-High Power™ PFC MegaPAC-EL™ (Low Noise)

MegaPAC™ Family Rev 1.6 Page 7 of 10 03/2016 MegaPAC™ Family MegaPAC Mechanical Drawings Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details. 9.40 (238,8) 1.80 (45,7) FAN 3.38 (85,8) 0.50 (12,7) 1.19 (30,2) 2.920 (74,2) 4.800 (121,8) 6.04 (153,4) 3.52 (89,4) 1.06 (26,9) J9-5 J9-1 0.45 (11,4) 5.10 (129,5) 0.60 (15,2) 8.78 (223,0) 2.91 (73,9) 1.93 (49,0) 1.40 (35,6) 2.74 (69,6) 0.62 (15,7) AIR FLOW TIGHTEN INNER NUTS DO NOT LOOSEN OR 0.040 X 0.13 SLOT STANDARD TYP. TYP. TYP.

45 IN-LBS ±5

(DUAL MOD) J1B-PIN1 (DUAL MOD) J1A-PIN1 J2B-PIN1 (SAME AS J2) (SAME AS J2) J2A-PIN1 R12 (SCALE: NONE) INPUT LEGEND OPTION IS SPECIFIED. WHEN ADJUSTABLE OUTPUT R4 "TRIMPOT" PRESENT (MODUPAC MODEL NO.) AS SHOWN (TYP) APPROXIMATELY LABEL LOCATED AS SHOWN APPROXIMATELY LABEL LOCATED MODUPAC REMOVAL MODUPACS, 5 PLACES TO SECURE/REMOVE #4-40 CAPTIVE SCREWS J3-PIN1 J2-PIN1 (EXAMPLE) AIR BLOCK OPTION AVAILABLE) (NO "POWER GOOD" DUAL MODUPAC -P1 +P1 +P5 -P5 TYP. SERRATED FLANGED NUTS 1/4 - 20 ZINC PLATED STEEL, MAXIMUM TORQUE 10 IN-LBS CLAMPING SCREWS FOR INPUT LEADS, MAX SCREW PENETRATION - 0.15 M4/#8-32 THDS 16 PLACES THRU J9-5) FOR #10 AWG INPUT WIRES 0.20 SQ. (5.2 MM) OPENINGS (J9-1 J10 (PIN 1) Mini MegaPAC L2S2 L1/N HERE. EARTH JUMPER

230 VAC

-OR-

115 VAC

1/4 - 20 ZINC PLATED STEEL, SERRATED FLANGED NUTS -P8 TYP. +P8 +P1 -P1 BUS BARS - FOR PARALLEL OUTPUTS BUS BAR - FOR SERIES OUTPUTS DUAL MODUPAC (NO "POWER GOOD" OPTION AVAILABLE) AIR BLOCK (EXAMPLE) J2-PIN1 J3-PIN1 #4-40 CAPTIVE SCREWS TO SECURE MODUPACS

10 PLACES

AS SHOWN (TYP) (MODUPAC MODEL NO.) R4 "TRIMPOT" PRESENT WHEN ADJUSTABLE OUTPUT OPTION IS SPECIFIED R12 J2A-PIN1 (SAME AS J2) (SAME AS J2) J2B-PIN1 J1A-PIN1 (DUAL MOD) J1B-PIN1 (DUAL MOD) TYP.TYP. TYP. 0.31 X 1.25 AMP MATES WITH HSG AMP NO. 747547-2 PLUS SLIDE STANDARD AIR FLOW (OUTER NUT ONLY) FOR FLAT RIBBON CABLE AMP NO. 746862-2 PLUG LATCH OR SIMILAR. DO NOT LOOSEN OR TIGHTEN INNER NUTS 6.56 (166,6) 1.40 (35,6) 0.25 (6,35) 1.15 (29,2) 0.54 (13,7) L2L1 2.068 (52,5) 0.240 (6,1) (12X) 1/8 X 1/2 SLOTS 1.852 (47,0) 0.560 (14,2) 0.46 (11,7) .15 MAX. PENETRATION (16X) M4/#8-32 TAPPED HOLE 0.40 (10,2) 1.852 (47,0) 1.20 (30,5) 7.50 (190,5) 4.00 (101,6) 1.20 (30,5) 0.65 (16,5) 5.10 (129,5) 1.64 (41,8) 11.95 (303,5) 12.28 (311,9) 4.90 (124,5) 4kW MegaPAC Mini MegaPAC™ 4kW MegaPAC™

MegaPAC™ Family Rev 1.6 Page 8 of 10 03/2016 MegaPAC™ Family Connection Diagrams – Input Connection Diagrams – Output PFC MegaPAC™ PFC MegaPAC-High Power™ PFC MegaPAC-EL™ PFC MegaPAC-HPEL™ Mini MegaPAC™ ModuPAC™ JuniorPAC™ RamPAC™ DualPAC™ BatPAC™ FinPAC™ 4kW MegaPAC™ 1 23 45 6 7 89 10 11 12 INPUT CONNECTIONS J9-3 L1/N J9-2 L2 J10 Interface J10-1 E/D-1 J10-2 E/D-2 J10-3 E/D-3 J10-4 E/D-4 J10-5 E/D-5 J10-6 E/D-6 J10-7 E/D-7 J10-8 E/D-8 J10-9 Vcc +5V, 0.3A J10-10 Signal Ground J10-11 AC Power OK J10-12 General Shutdown J9-1 Earth Ground Housing-Molex P/N: 39-01-2120 Terminal-Molex P/N: 39-00-0039 Crimp Tool-Molex P/N: 11-01-0197 J10 J2-PIN1 J3-PIN1 0UTPUT ADJUST +V0UT –VOUT (REMOTE SENSE)J2 3 –SENSE +SENSE MATING HARDWARE TRIM PIN ACCESS

3 POWER GOOD

1 SIGNAL GROUND

J3 DC OK (POWER GOOD) VCC IN HOUSING- MOLEX P/N: 50-57-9403 TERMINALS- MOLEX P/N: 16-02-0103 CRIMP TOOL MOLEX P/N: 63811-8700 HOUSING- MOLEX P/N: 50-37-5043 TERMINALS- MOLEX P/N: 08-70-1040 CRIMP TOOL MOLEX P/N: 63811-5200 MODUPAC, JRPAC, RAMPAC VOLTAGE LIMIT ADJUST J2 (BATPAC REMOTE INTERFACE) CURRENT MONITOR CURRENT LIMIT ADJUST – VOUT VOLTAGE LIMIT ADJUST – VOUT J2-PIN1 CURRENT LIMIT ADJUST CRIMP TOOL MOLEX P/N: 63811-5200 TERMINALS- MOLEX P/N: 08-70-1040 HOUSING- MOLEX P/N: 50-37-5043 MATING HARDWARE BATPAC + V0UT+ V0UT J2-B-PIN1 OUTPUT ADJUST J2-A-PIN1 J2 (REMOTE SENSE) MATING HARDWARE HOUSING- MOLEX P/N: 50-57-9403 TERMINALS- MOLEX P/N: 16-02-0103 CRIMP TOOL MOLEX P/N: 11-01-02083 –SENSE + SENSE

1 TRIM PIN ACCESS

(OUTPUT CONNECTORS)

1 AND 4 +VOUT

3 3 +R/SENSE 6 –R/SENSE TERMINALS- MOLEX P/N: 39-00-0039 HOUSING- MOLEX P/N: 39-01-2060 CRIMP TOOL MOLEX P/N: 11-01-0197 MATING HARDWARE

2 AND 5 –VOUT

RIM/SC & POWER GOOD POWER GOOD INVERTED TRIM5 +SENSE –SENSE TERMINALS- MOLEX P/N: 08-70-1040 HOUSING- MOLEX P/N: 50-37-5073 CRIMP TOOL MOLEX P/N: 63811-5200 MATING HARDWARE P2-PIN1 –VOUT OUTPUT ADJUST FINPAC + VOUT 1 23 45 6 7 89 10 11 12 INPUT CONNECTIONS J9-5 120VAC J9-4 120VAC J10 Interface J10-1 E/D-1 J10-2 E/D-2 J10-3 E/D-3 J10-4 E/D-4 J10-5 E/D-5 J10-6 N/C J10-7 N/C J10-8 N/C J10-9 VCC +5V, 0.3A J10-10 Signal Ground J10-11 AC Power OK J10-12 General Shutdown J9-3 AC Neutral J9-2 AC Hot J9-1 Earth Ground Molex header Mini-fit Jr. 12 POS #39-30-1120 Customer I/O interface mating receptacle Molex #39-01-2120with terminal #39-00-0039 and 18-24 AWG str anded wire. Use Molex tool #11-01-0197 } Jumper for 115V operation J10 INPUT CONNECTIONS J1-1 Line 3 J1-2 Line 2 J1-3 Line 1 J1-4 Earth Ground Amp 25 pin connector #841-17-DBFR-DA25P plug for flat ribbon cable. Mates with housing ADAM TECH #DB25-SR-SL and contacts #DCS-01B plus slide latch #HDW-043-25. J10 Interface

1 Signal Ground 14 Phase Fail Warning

2 Signal Ground 15 Signal Ground

3 Overtemp.Warning 16 Vcc +5 volt, 300 mA

4 Analog Temperature 17 Vcc +5 volt, 300 mA

5 General Shutdown 18 AC Power OK

6 No Connection 19 AC Power Fail

7 Enable/Disable #10 20 Enable/Disable #9

8 Enable/Disable #8 21 Enable/Disable #7

9 Enable/Disable #6 22 Enable/Disable #5

10 Enable/Disable #4 23 Enable/Disable #3

11 Enable/Disable #2 24 Enable/Disable #1

12 Signal Ground 25 Gate Out Slot #10 (isolated)

13 Gate In Slot #1 (isolated)2 3 4 5 6 71 8 9 10 11 12 13

14 15 16 17 18 19 20 21 22 23 24 25

MegaPAC™ Family Rev 1.6 Page 9 of 10 03/2016 MegaPAC™ Family Connection Diagrams – Output (Cont.) ConverterPAC™ Options [f] FinPACs and FinQPACs require two slots. [g] Module dependent, 3.3V, 10 – 15V “T” option only. [h] All QPACs and RamPACs have output ripple of 10mVP-P or 0.15% whichever is greater. [i] Per slot-based indicator. QPAC™ JuniorQPAC™ DualQPAC™ FinQPAC™ QPAC (L), JrQPAC (LJ) TERMINALS- MOLEX P/N: 08-70-1040 HOUSING- MOLEX P/N: 50-37-5073 CRIMP TOOL MOLEX P/N: 63811-5200 MATING HARDWARE +SENSE POWER GOOD SIGNAL GROUND POWER GOOD INVERTED VCC IN P2-PIN1 TRIM –SENSE OUTPUT ADJUST P2 REMOTE SENSE TRIM/SC & POWER GOOD –VOUT +VOUT P2 REMOTE SENSE T RIM/SC & POWER GOOD POWER GOOD INVERTED TRIM5 +SENSE –SENSE TERMINALS- MOLEX P/N: 08-70-1040 HOUSING- MOLEX P/N: 50-37-5073 CRIMP TOOL MOLEX P/N: 63811-5200 MATING HARDWARE P2-PIN1 –VOUT OUTPUT ADJUST FINPAC + VOUT J1-B-PIN1 (OUTPUT CONNECTORS) 3 3 +R/SENSE 6 –R/SENSE J1-A TERMINALS- MOLEX P/N: 39-00-0039 HOUSING- MOLEX P/N: 39-01-2060 CRIMP TOOL MOLEX P/N: 11-01-0197 MATING HARDWARE 3 +R/SENSE 6 –R/SENSE6 J1-B (OUTPUT CONNECTORS)

1 AND 4 +VOUT1

TERMINALS- MOLEX P/N: 39-00-0039 CRIMP TOOL MOLEX P/N: 11-01-0197 HOUSING- MOLEX P/N: 39-01-2060 MATING HARDWARE TRIM BOT Option ModuPAC™ (M) BatPAC™ (B) DualPAC™ (D) JuniorPAC™ (J) RamPAC™ (R) DualQPAC™ (LD) QPAC™ (L) JuniorQPAC™ (LJ) UniPAC™ (XU) FinPAC™ (PZ) [f] FinQPAC™ (PLZ) [f] D Power Good OPT NA NA OPT OPT [i] OPT [i] OPT OPT OPT OPT OPT T Trim: +10%/–10% OPT [g] NA OPT OPT [g] OPT [g] NA OPT [g] OPT OPT OPT OPT F Trim: +10%/–50% OPT [g] NA OPT OPT [g] OPT [g] NA OPT [g] OPT OPT OPT OPT V1 VXI Low Noise (150mVP-P 15V < VOUT ≤ 24V) OPT NA OPT OPT NA [h] NA [h] NA [h] NA [h] NA NA NA [h] V2 VXI Low Noise (50mVP-P ≤ 15V) OPT NA OPT OPT NA NA NA NA NA NA NA V3 VXI Low Noise (1% VOUT > 24V) OPT NA OPT OPT NA NA NA NA NA NA NA Parallelable STD STD NA NA NA NA STD NA STD STD STD Autosense STD NA STD STD NA STD STD STD STD STD STD

MegaPAC™ Family Rev 1.6 Page 10 of 10 03/2016 MegaPAC™ Family Contact Us: http://www.vicorpower.com/contact-us Vicor Corporation

25 Frontage Road

Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 www.vicorpower.com email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit http://www.vicorpower.com/megapac for the latest product information. Vicor’s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. ©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation. All other trademarks, product names, logos and brands are property of their respective owners.